NextSDS Logo
Se

Selemix Fast Dry Extra primer PB free - variable pack sizes

WARNING Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Selemix Fast Dry Extra primer PB free - variable pack sizes
Product Form
Liquid.
Product Code
7.820-MX01/EX

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Professional applications, Used by spraying. Coating.
Uses Advised Against
Product is not intended, labelled or packaged for consumer use.

Overview

Selemix Fast Dry Extra primer PB free - variable pack sizes commonly used professional applications, used by spraying. coating..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226
Eye Irrit. Category 2 H319
STOT SE Category 3 H336
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P261: Avoid breathing vapour.
  • P273: Avoid release to the environment.
  • P280: Wear eye or face protection.
  • P391: Collect spillage.
  • P501: Dispose of contents and container in accordance with all local, regional, national and international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PPG Industries Italia S.r.l.

undefined

๐Ÿ“

Via Comasina, 121, 20161 Milano, Italy

๐ŸŒ

IT

PPG Industries (UK) Ltd.

undefined

๐Ÿ“

Needham Road, Stowmarket, Suffolk, IP14 2AD, UK

๐ŸŒ

GB

๐Ÿ“ž

+44 (0) 1449 773 338

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

PPG Industries Italia S.r.l.

๐Ÿ“ž

+39 02 6404.1

๐ŸŒ

IT

๐Ÿ•’

0800-1700

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
n-butyl acetate
EC: 204-658-1
123-86-4 10-25% โš ๏ธ Hazardous
trizinc bis(orthophosphate)
EC: 231-944-3
7779-90-0 5-10% โš ๏ธ Hazardous
xylene
EC: 215-535-7
1330-20-7 5-7.8% โš ๏ธ Hazardous
Hydrocarbons, C9, aromatics < 0.1% cumene
EC: 918-668-5
128601-23-0 1-5% โš ๏ธ Hazardous
butan-1-ol N/A 0.1-2.1% โš ๏ธ Hazardous
2-methoxy-1-methylethyl acetate
EC: 203-603-9
108-65-6 1-5% โš ๏ธ Hazardous
ethylbenzene
EC: 202-849-4
100-41-4 1-5% โš ๏ธ Hazardous
zinc oxide
EC: 215-222-5
1314-13-2 0.3% โš ๏ธ Hazardous

Composition Notes

Xylene: Several REACH registrations cover the REACH registered substance with xylene isomers, ethylbenzene (and toluene). The other REACH Registrations include: 01-2119555267-33 reaction mass of ethylbenzene and m-xylene and p- xylene, 01-2119486136-34 Aromatic hydrocarbons, C8, 01-2119539452-40 reaction mass of ethylbenzene and xylene.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Symptoms:

Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness. Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser. Do NOT use solvents or thinners.

Symptoms:

Adverse symptoms may include the following: irritation, dryness, cracking. Defatting to the skin. May cause skin dryness and irritation.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, irrigate copiously with clean, fresh water, holding the eyelids apart for at least 10 minutes and seek immediate medical advice.

Symptoms:

Causes serious eye irritation. Adverse symptoms may include the following: pain or irritation, watering, redness.

๐Ÿฝ๏ธ Ingestion/Swallowing

If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Symptoms:

Can cause central nervous system (CNS) depression.

๐Ÿšจ Immediate Medical Attention Required

Seek immediate medical advice for eye contact or if swallowed. In case of inhalation of decomposition products in a fire, symptoms may be delayed and the exposed person may need to be kept under medical surveillance for 48 hours.

Medical Treatment

No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Auto Ignition Temperature
280 to 470 ยฐC (536 to 878 ยฐF)
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Properties Status
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿงช Ph
Not applicable.
๐Ÿ”ฅ Flash Point
Closed cup: 23ยฐC (73.4ยฐF)
Critical Property
๐Ÿ”ฅ Flammability
liquid
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ’จ Boiling Point
>37.78ยฐC (>100ยฐF)
Critical Property
๐Ÿ’ง Solubility
insoluble in water. Media Result cold water Not soluble. Miscible with water : No.
๐Ÿ“Š Decomposition Temperature
Not available
๐ŸŽจ Colour
Various
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ‘ƒ Odor
Characteristic.
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Solubility In Water
insoluble in water; Not soluble in cold water; Not miscible with water.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿงช Physical State
Liquid.
Critical Property
๐ŸงŠ Melting Point
Not available
๐Ÿ“Š Relative Density
1.3
๐Ÿ“Š Dynamic Viscosity
Not available. (room temperature)
โš–๏ธ Density
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š Softening Point
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ“Š Form
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ“Š Kinematic Viscosity
>21 mm[2] /s (40ยฐC)
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ’จ Vapor Pressure
11.25096 mm Hg (1.5 kPa) at 20หšC (n-butyl acetate)
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Partition Coefficient
Not applicable.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

๐Ÿงค Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment. For prolonged or repeated handling, use the following type of gloves: Recommended: polyvinyl alcohol (PVA), natural rubber (latex), Vitonยฎ, butyl rubber, neoprene. May be used: Chloroprene, nitrile rubber.

๐Ÿ‘๏ธ Eye Protection

Chemical splash goggles.

๐Ÿ˜ท Respiratory Protection

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Wear a respirator conforming to EN140. Filter type: organic vapour (Type A) and particulate filter P3

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

The product is stable.

โš—๏ธ Reactivity

No specific test data related to reactivity available for this product or its ingredients.

โš ๏ธ Hazardous Reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

๐Ÿšซ Conditions to Avoid

When exposed to high temperatures may produce hazardous decomposition products.

๐Ÿงช Incompatible Materials

oxidising agents, strong alkalis, strong acids

๐Ÿ’จ Hazardous Decomposition Products

Depending on conditions, decomposition products may include the following materials: carbon oxides nitrogen oxides sulfur oxides phosphorus oxides Formaldehyde. metal oxide/oxides

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1263

๐Ÿ“ฆ Proper Shipping Name

PAINT

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Transport within userโ€™s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

๐Ÿšข IMDG Maritime Transport Precautions

Transport within userโ€™s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

โœˆ๏ธ IATA Air Transport Precautions

Transport within userโ€™s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Selemix Fast Dry Extra primer PB free - variable pack sizes?

The signal word for this substance is "warning".

What is the physical form of Selemix Fast Dry Extra primer PB free - variable pack sizes?

Selemix Fast Dry Extra primer PB free - variable pack sizes is a liquid. with various color. It has characteristic. odor.

What is the solubility of Selemix Fast Dry Extra primer PB free - variable pack sizes?

insoluble in water. Media Result cold water Not soluble. Miscible with water : No.

What is Selemix Fast Dry Extra primer PB free - variable pack sizes used for?

Professional applications, Used by spraying. Coating.