NextSDS Logo
Safety Data Sheet EN

BOBCAT CHARCOAL TOPCOAT SPRAY 0400

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BOBCAT CHARCOAL TOPCOAT SPRAY 0400
Product Code
00359024

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial applications, Used by spraying. Coating.

Manufacturers & Suppliers

P

PPG France Manufacturing SAS

manufacturer

Route d'Estreux B.P.6 59990 Saultain France

+33 (0)3 27 19 88 00

Emergency Contacts

Supplier

+33 (0)3 27 14 97 00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

F+

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

There are no ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a workplace exposure limit and hence require reporting in this section.

Type - [1] Substance classified with a health or environmental hazard - [2] Substance with a workplace exposure limit - [3] Substance meets the criteria for PBT according to Regulation (EC) No. 1907/2006, Annex XIII - [4] Substance meets the criteria for vPvB according to Regulation (EC) No. 1907/2006, Annex XIII - [5] Substance of equivalent concern

Notes

See Section 16 for See Section 16 for the the full text of the R- full text of the H phrases declared statements declared above. above.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Symptoms: respiratory tract irritation, coughing

Skin contact

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser.

Eye contact

Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open. Seek immediate medical attention.

Symptoms: irritation, redness

Ingestion

If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Immediate Medical Attention

Seek immediate medical attention for eye contact. If swallowed, seek medical advice immediately and show the container or label. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

Flammable aerosol. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed. Runoff to sewer may create fire or explosion hazard.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. In the case of aerosols being ruptured, care should be taken due to the rapid escape of the pressurised contents and propellant. If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant. Contain and collect spillage.

Materials: water, inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C. Do not pierce or burn, even after use. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Avoid breathing vapour or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use non-sparking tools. Empty containers retain product residue and can be hazardous.

Storage

Storage temperature: 5 to 35°C (41 to 95°F). Store in accordance with local regulations. Store in a segregated and approved area. Store away from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Eliminate all ignition sources. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Eliminate all ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapour or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Glove materials: nitrile rubber, butyl rubber, PVC, Viton®

Eyes

Safety glasses with side shields.

Respiratory

If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
Aerosol.
Colour
Black.
Colour Intensity
---
Form
Aerosol.
Odor
Black.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
<35°C
Flash Point
Closed cup: -21°C
Freezing Point
Not available.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
---
Vapor Density
---
Relative Density
0.8
Bulk Density
---
Density
---
Flammability
Material supports combustion. Yes. Flammability (solid, gas): Not available.
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Insoluble in the following materials: cold water.
Partition Coefficient
Not available.
Solubility In Water
Insoluble in cold water.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
< 30 s (ISO 6mm)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

When exposed to high temperatures may produce hazardous decomposition products.

Incompatible

oxidising agents, strong alkalis, strong acids.

Decomposition

carbon monoxide, carbon dioxide, smoke, oxides of nitrogen.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Conclusion/Summary - : Not available.

Not available.

Persistence and degradability

Conclusion/Summary - : Not available.

Not available.

Bioaccumulative potential

Not available.

Not available.

Mobility in soil

Soil/water partition coefficient (KOC) Mobility : Not available. : Not available.

Results of PBT and vPvB assessment

- PBT : Not applicable. vPvB - : Not applicable.

Other adverse effects

- : No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimised wherever possible. Waste product residues should not be disposed of via the sewer but processed in a suitable effluent treatment plant. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Disposal

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Waste Codes

08 01 11* waste paint and varnish containing organic solvents or other dangerous substances EWC
15 01 04 metallic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
ADR

Transport within users premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within users premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within users premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BOBCAT CHARCOAL TOPCOAT SPRAY 0400?

The signal word is na: r-phrases.

What is the physical form of BOBCAT CHARCOAL TOPCOAT SPRAY 0400?

BOBCAT CHARCOAL TOPCOAT SPRAY 0400 is a liquid. appearing as aerosol. with black. color. It has black. odor.

What is the solubility of BOBCAT CHARCOAL TOPCOAT SPRAY 0400?

Insoluble in the following materials: cold water.

What is BOBCAT CHARCOAL TOPCOAT SPRAY 0400 used for?

Industrial applications, Used by spraying. Coating.

What is the melting point of BOBCAT CHARCOAL TOPCOAT SPRAY 0400?

The melting point is Not available. and the boiling point is <35°C.