Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Top Coat Grey 5002
- Product Form
- Liquid
- Product Code
- 17480426
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Paint.
Uses advised against
Not applicable.
Manufacturers & Suppliers
SMT GB
national supplier
Moorfield Road, Duxford, CB22 4QX
07544 657748
Emergency Contacts
Emergency Contact
+1 813-248-0585
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Xylene EC: 215-535-7 | 1330-20-7 | 10 - 25% | Yes |
| crystalline silica, respirable powder EC: 238-878-4 | 14808-60-7 | 10% | Yes |
| n-Butyl acetate EC: 204-658-1 | 123-86-4 | 5% | Yes |
| Ethylbenzene EC: 202-849-4 | 100-41-4 | 5% | Yes |
| aluminium dihydrogen triphosphate EC: 237-714-9 | 13939-25-8 | 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.
Symptoms: The product is irritating to mucous membranes and upper respiratory tract. Adverse symptoms may include the following: respiratory tract irritation, coughing. May cause damage to organs through prolonged or repeated exposure.
Wash contaminated skin with soap and water. Get medical attention.
Symptoms: Skin inflammation is characterized by itching, scaling, reddening or, occasionally, blistering.
In case of contact with eyes, rinse immediately with plenty of water. Remove contact lenses, if present and easy to do. Continue rinsing. Continue to rinse for at least 10 minutes. Get medical attention if symptoms occur.
Symptoms: Inflammation of the eye is characterized by redness, watering and itching.
Wash out mouth with water. Get medical attention if symptoms occur.
Symptoms: Adverse symptoms may include the following: burning in throat
Immediate Medical Attention
Treat symptomatically.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Recommended: CO₂, powders, Foam
Do not use water jet.
Flammable liquid and vapor. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along the ground. Vapors may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. Runoff to sewer may create fire or explosion hazard.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation. Refer to protective measures listed in sections 7 and 8.
Stop leak if without risk. Use spark-proof tools and explosion-proof equipment. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Contain and collect spillage with non-combustible, absorbent material.
Materials: sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat, sparks and flame. Keep away from sources of ignition. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment (see Section 8). Do not breathe vapor or mist. Empty containers retain product residue and can be hazardous. Do not reuse container. Avoid contact with eyes, skin and clothing. Do not ingest. Store and use away from heat, sparks, open flame or any other ignition source. Wash thoroughly after handling. Do not eat, drink or smoke when using this product.
Store in a segregated and approved area. Store locked up. Keep container tightly closed. Keep container in a cool, well-ventilated area.
Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Wash contaminated clothing before reuse.
Keep away from heat, sparks and flame. Keep away from sources of ignition. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. To avoid fire or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before transferring material. Take precautionary measures against electrostatic discharges. Use only non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. If this product contains ingredients with exposure limits, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits. Where reasonably practicable, this should be achieved by the use of local exhaust ventilation and good general extraction. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use explosion-proof ventilation equipment.
For prolonged or repeated handling, use gloves > 8 hours (breakthrough time). Chemically resistant gloves, EN374. Recommended: PE Laminate or polyvinyl alcohol (PVA) >0.3 mm, 240 minutes (breakthrough time). Short term exposure: nitrile rubber gloves < 1 hour (breakthrough time): <10 minutes, >0.12 mm thickness.
Recommended: Use eye protection according to EN 166, designed to protect against liquid splashes. Ensure that eyewash stations and safety showers are close to the workstation location.
Provide adequate ventilation. Recommended: Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary. Recommended filter combination: A2-P2. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Provide adequate ventilation.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Recommended: Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Recommended: Wear protective shoes. Barrier creams may help to protect the exposed areas of the skin but should not be applied once exposure has occurred.
Do not allow to enter drains or watercourses.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. Do not allow vapor to accumulate in low or confined areas.
strong acids, strong alkalis, oxidizing materials
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- Paint
- Transport Class
- 3
- Packing Group
- III
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Top Coat Grey 5002?
The signal word is warning.
What is the physical form of Top Coat Grey 5002?
Top Coat Grey 5002 is a liquid with gray. color. It has solvent. odor.
What is Top Coat Grey 5002 used for?
Paint.
What are the hazard statements for Top Coat Grey 5002?
This substance has 5 hazard statements:
- H226: Flammable liquid and vapor.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H372: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of Top Coat Grey 5002?
The melting point is Not available. and the boiling point is 123°C (253.4°F).