NextSDS Logo
Safety Data Sheet EN

DRY BLEND F

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DRY BLEND F

Regulatory Identifiers

CAS Number
N/A
REACH No.
Exempted

Identified Uses

Industrial use: Plastics engineering (eg. extrusion, injection molding, calandering)

Manufacturers & Suppliers

DUMA COMPOUND nv logo

DUMA COMPOUND nv

manufacturer

Vliegplein 41, B - 9990 Maldegem

+32 50 72 90 11

http://www.dumaplast.be

Emergency Contacts

Luc Dhaene

+32 50 72 90 13

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Product: Non mandatory labeling, however it is necessary to observe the common precautionary measures for contact with chemicals.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Rigid PVC Compound

Chemical Name CAS Number Concentration Hazardous
Calcium acetylacetonate EC: 243-001-3 19372-44-2 0.1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation of decomposition products, breathe fresh air into the patient and keep the patient at rest. Take medical treatment.

Skin contact

In case of contact with the skin, wash with soap and water. Do not remove the solidified product on the skin.

Eye contact

In case of contact with the eyes, rinse immediately with plenty of water.

Ingestion

If accidentally swallowed, drink plenty of water and seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Cooperative / accommodating to all common extinguishing agents.

Specific hazards

In case of fire, gas release of hazardous combustion: Carbon monoxide (CO), Carbon dioxide (CO₂), Hydrochloric acid (HCl)

Firefighter Protection

In case of fire use a respirator that is independent of the circulating air.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not dispose into the drains / surface water / groundwater.

Cleanup methods

Pick up mechanically and send for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure a good exhaust / ventilation on the treatment machine.

Storage

Do not expose to prolonged heat action. Do not store at temperatures above 30° C. In the original container tightly closed and stock temperature of up to 25° C.

Fire prevention

Avoid the accumulation of electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

see point 7; no excessive measures are necessary.

Hands

Protective gloves against heat during the processing of the product.

Eyes

Safety glasses

Respiratory

In case of dust, wear a fine dust mask

Skin/Body

Specific measures for body protection are not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Crystallisation Point
---
Solidification Point
---
Boiling Point
---
Vapor Density
---
Form
powder
Freezing Point
---
Flash Point
> 190°C
Melting Point
---
State Under Standard Conditions
---
Relative Density
---
Density
> 1 g/cm³
Solubility In Water
insoluble
Physical State Data
solid
Kinematic Viscosity
---
Voc Content
---
Colour
variable according to the coloring
Colour Intensity
---
Cloud Point
---
Relative Evaporation Rate
---
Upper Explosive Limit
---
Metal Corrosion
---
Odor
hardly noticeable
Softening Point
> 120°C
Odor Threshold
---
Partition Coefficient
---
Dynamic Viscosity
---
Lower Explosive Limit
---
Appearance
powder
Vapor Pressure
---
Solubility In Fat
---
Flammability
---
Auto Ignition Temperature
> 300°C
Properties Status
---
Molecular Weight
---
Decomposition Temperature
---
Solubility
---
Evaporation Rate
---
Bulk Density
ca. 0,5 – 1 g/ml
Physical State
powder
Ph
---
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

Possibility of release of toxic vapors by heating on decomposition temperature.

Decomposition

Excessive thermal load capacity on time and temperature can lead to decomposition between hydrochloric detachment (hydrochloric acid)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

The waste code shown according to regulations of waste classification is counted as a recommendation. The final waste code should be assigned by the authorities responsible for the disposal of local waste.

Waste Codes

07 02 13 plastic waste EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DRY BLEND F?

The signal word is no signal word.

What is the physical form of DRY BLEND F?

DRY BLEND F is a powder appearing as powder with variable according to the coloring color. It has hardly noticeable odor.

What is DRY BLEND F used for?

Industrial use: Plastics engineering (eg. extrusion, injection molding, calandering)