NextSDS Logo
Safety Data Sheet EN

Therminol® 59 Heat Transfer Fluid

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Therminol® 59 Heat Transfer Fluid
Product Code
34128-00, P3412805, P3412807, P3412801, P3412800, P3412804, P3412806, P3412808, E3412801

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119472547-29-0001

Identified Uses

Heat transfer fluids

Uses advised against

None known.

Manufacturers & Suppliers

Eastman Chemical Company logo

Eastman Chemical Company

manufacturer

200 South Wilcox Drive, 37660-5280 Kingsport

+14232292000

http://www.EASTMAN.com

Emergency Contacts

NCEC

+44 (0)1235 239 670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2 H315
Skin Sens. Cat. 1 H317
Asp. Tox. Cat. 1 H304
Aquatic Acute Cat. 1 H400
Aquatic Chronic Cat. 1 H410

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H304 May be fatal if swallowed and enters airways.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H410 Very toxic to aquatic life with long lasting effects.

Precautionary Statements

P261 Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray.
P273 Avoid release to the environment.
P280 Wear protective gloves.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor.
P331 Do NOT induce vomiting.
P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Benzene, ethylenated, by-products from EC: 271-802-8 68608-82-2 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing. If breathing is difficult, give oxygen. Get medical attention if symptoms occur.

Skin contact

Wash off with soap and plenty of water. Wash contaminated clothing before reuse. Get medical attention if symptoms occur.

Symptoms: May cause an allergic skin reaction. Causes skin irritation. The molten product can cause serious burns.

Eye contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if symptoms occur.

Ingestion

Immediately call a POISON CENTER/doctor. Do NOT induce vomiting.

Symptoms: Aspiration hazard

Immediate Medical Attention

Immediately call a POISON CENTER/doctor.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, Carbon dioxide (CO2), Dry chemical, Foam

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire.

Firefighter Protection

Wear an approved positive pressure self-contained breathing apparatus in addition to standard fire fighting gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors or spray mist. Avoid contact with skin and eyes. Material can create slippery conditions.

Environmental

Clear up spills immediately and dispose of waste safely. Avoid release to the environment. Collect spillage.

Cleanup methods

soak up with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and transfer to a container for disposal according to local / national regulations (see section 13).

Materials: non-combustible absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapors or spray mist. Handle product only in closed system or provide appropriate exhaust ventilation at machinery. In case of insufficient ventilation, wear suitable respiratory equipment. Keep away from flames and sparks. Wear appropriate personal protective equipment. Avoid contact with skin, eyes and clothing. Wash thoroughly after handling. Wash contaminated clothing before reuse. Drain or remove substance from equipment prior to break-in or maintenance. Handle in accordance with good industrial hygiene and safety practice.

Storage

Keep container tightly closed in a dry and well-ventilated place. Keep in a cool place away from oxidizing agents.

Hygiene

Wash thoroughly after handling. Wash contaminated clothing before reuse. Handle in accordance with good industrial hygiene and safety practice.

Fire prevention

Keep away from flames and sparks.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Material: Neoprene, Nitrile rubber, PVC. Remarks: Wear suitable gloves. After contamination with product change the gloves immediately and dispose of them according to relevant national and local regulations. 1) In case of contact through splashing: The breakthrough time of the glove material, with regard to the amount and duration of dermal exposure: 1 to 4 hours.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn.

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
colourless, light yellow
Colour Intensity
---
Form
---
Odor
aromatic, hydrocarbon-like
Odor Threshold
not determined
Ph
not determined
Melting Point
---
Boiling Point
289 °C (1.013 hPa)
Flash Point
Pensky-Martens closed cup: 132 °C
Freezing Point
-68 °C (1.013 hPa)
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
0,15 Pa (25 °C)
Vapor Density
---
Relative Density
0,979 (25 °C)
Bulk Density
---
Density
971 kg/m3 (25 °C)
Flammability
Not applicable
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
not determined
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
---
Solubility In Water
0,55 mg/l (25 °C)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
not determined
Kinematic Viscosity
4,0 mm2/s (40 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None reasonably foreseeable.

Hazardous reactions

None known.

Avoid

Heating in air. Keep away from flames and sparks.

Incompatible

Strong oxidizing agents

Decomposition

Emits acrid smoke and fumes when heated to decomposition.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Product: M-Factor (Acute aquatic toxicity) : 1 M-Factor (Chronic aquatic toxicity) : 1 Components: Benzene, ethylenated, by-products from:

The product is classified with an M-Factor of 1 for both acute and chronic aquatic toxicity.

12.1 Toxicity

Benzene, ethylenated, by-products from: Toxicity to fish : LC50 (Oncorhynchus mykiss (rainbow trout)): > 0,97 mg/l Exposure time: 96 h Toxicity to daphnia and other aquatic invertebrates : LC50 (Ceriodaphnia dubia (water flea)): 0,029 mg/l Exposure time: 48 h Toxicity to algae/aquatic plants : EC50 (Pseudokirchneriella subcapitata (algae)): 0,485 mg/l Exposure time: 72 h NOEC (Pseudokirchneriella subcapitata (algae)): 0,0959 mg/l Exposure time: 72 h M-Factor (Acute aquatic toxicity) : 1

12.2 Persistence and degradability

Components: Benzene, ethylenated, by-products from:

12.2 Persistence and degradability

Benzene, ethylenated, by-products from: Biodegradability : Result: Inherently biodegradable.

12.3 Bioaccumulative potential

Benzene, ethylenated, by-products from: Bioaccumulation : Bioconcentration factor (BCF): 250 - 1.090 Partition coefficient: n-octanol/water : Pow: 12.000 - 1.020.000 log Pow: 4,08 - 6,01

12.4 Mobility in soil

**Components:** **Benzene, ethylenated, by-products from:** Distribution among environmental compartments : log Koc: 3,7

12.5 Results of PBT and vPvB assessment

This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher..

The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

12.6 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with local regulations.

Disposal

Dispose of in accordance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Benzene, ethylenated, by-products from)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Therminol® 59 Heat Transfer Fluid?

The signal word is danger.

What is the physical form of Therminol® 59 Heat Transfer Fluid?

Therminol® 59 Heat Transfer Fluid is a liquid appearing as liquid with colourless, light yellow color. It has aromatic, hydrocarbon-like odor.

What is Therminol® 59 Heat Transfer Fluid used for?

Heat transfer fluids

What are the hazard statements for Therminol® 59 Heat Transfer Fluid?

This substance has 4 hazard statements:

  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H410: Very toxic to aquatic life with long lasting effects.