NextSDS Logo
Safety Data Sheet EN

Everbuild Mitre Fast Activator

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Everbuild Mitre Fast Activator

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesive

Manufacturers & Suppliers

E

Everbuild – A Sika Company

manufacturer

Site 41, Knowsthorpe Way, Cross Green Industrial Estate, Leeds, West Yorkshire LS9 0SW, United Kingdom

0113 240 3456

Emergency Contacts

Emergency Contact

0044 113 240 3456

office hours only

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
P273 Avoid release to the environment.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
N/A --- 25 - 40% Yes
N,N-dimethyl-p-toluidine EC: 202-805-4 99-97-8 0.25 - 1% Yes
petroleum gases, liquefied EC: 270-704-2 68476-85-7 25 - 40% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.

Eye contact

Remove contact lenses. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Do not induce vomiting without medical advice. Rinse mouth with water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water/water spray/water jet/carbon dioxide/sand/foam/alcohol resistant foam/chemical powder for extinction.

Unsuitable media

Water

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Instructions

Use water spray to cool unopened containers.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Deny access to unprotected persons.

Environmental

Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours or spray mist. Avoid exceeding the given occupational exposure limits. Do not get in eyes, on skin, or on clothing. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharge. Open drum carefully as content may be under pressure.

Storage

BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. Store in original container. Keep container tightly closed in a dry and well-ventilated place.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.

Fire prevention

Keep away from heat/ sparks/ open flames/ hot surfaces. No smoking. Do not spray on a naked flame or any incandescent material. Take precautionary measures against electrostatic discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas.

Hands

Chemical-resistant, impervious gloves complying with an approved standard must be worn at all times when handling chemical products. Reference number EN 374. Follow manufacturer specifications. Suitable for short time use or protection against splashes: Butyl rubber/nitrile rubber gloves (0,4 mm). Contaminated gloves should be removed. Suitable for permanent exposure: Viton gloves (0.4 mm), breakthrough time >30 min.

Eyes

Safety glasses with side-shields conforming to EN166

Respiratory

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. organic vapor (Type A) and particulate filter A1: < 1000 ppm; A2: < 5000 ppm; A3: < 10000 ppm P1: Inert material; P2, P3: hazardous substances. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.

Skin/Body

Protective clothing (e.g. Safety shoes acc. to EN ISO 20345, long-sleeved working clothing, long trousers).

Environmental

Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
No data available
Molecular Weight
---
Relative Density
---
Solidification Point
---
Colour Intensity
---
Vapor Density
---
Solubility In Fat
---
Decomposition Temperature
No data available
Solubility In Water
No data available
Boiling Point
No data available
Flash Point
-40 °C
Appearance
aerosol
Solubility
---
Lower Explosive Limit
1,1 %(V)
State Under Standard Conditions
---
Physical State Data
aerosol
Form
---
Properties Status
---
Voc Content
---
Evaporation Rate
No data available
Kinematic Viscosity
Not applicable
Freezing Point
No data available
Density
0,67 g/cm3
Ph
Not applicable
Crystallisation Point
---
Colour
various
Odor Threshold
No data available
Softening Point
---
Metal Corrosion
---
Explosive Limits
---
Flammability
No data available
Bulk Density
---
Relative Evaporation Rate
---
Upper Explosive Limit
7,4 %(V)
Cloud Point
---
Odor
No data available
Physical State
aerosol
Auto Ignition Temperature
No data available
Vapor Pressure
34,6637 hPa
Partition Coefficient
No data available
Melting Point
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

Stable under recommended storage conditions.

Avoid

Heat, flames and sparks.

Incompatible

No data available

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe way. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

15 01 10* packaging containing residues of or contaminated by dangerous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2
Packing Group
Not assigned by regulation
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No Chemical Safety Assessment has been carried out for this mixture by the supplier.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Everbuild Mitre Fast Activator?

The signal word is danger.

What is the physical form of Everbuild Mitre Fast Activator?

Everbuild Mitre Fast Activator is a aerosol appearing as aerosol with various color. It has no data available odor.

What is Everbuild Mitre Fast Activator used for?

Adhesive

What are the hazard statements for Everbuild Mitre Fast Activator?

This substance has 5 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Everbuild Mitre Fast Activator?

The melting point is No data available and the boiling point is No data available.

Compliance Scanner

Scan your compliance