Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Everbuild Mitre Fast Activator
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive
Manufacturers & Suppliers
Everbuild – A Sika Company
manufacturer
Site 41, Knowsthorpe Way, Cross Green Industrial Estate, Leeds, West Yorkshire LS9 0SW, United Kingdom
0113 240 3456
Emergency Contacts
Emergency Contact
0044 113 240 3456
office hours only
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 25 - 40% | Yes |
| N,N-dimethyl-p-toluidine EC: 202-805-4 | 99-97-8 | 0.25 - 1% | Yes |
| petroleum gases, liquefied EC: 270-704-2 | 68476-85-7 | 25 - 40% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.
Remove contact lenses. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Do not induce vomiting without medical advice. Rinse mouth with water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water/water spray/water jet/carbon dioxide/sand/foam/alcohol resistant foam/chemical powder for extinction.
Water
Do not allow run-off from fire fighting to enter drains or water courses.
Use water spray to cool unopened containers.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Deny access to unprotected persons.
Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.
Related Products
Similar products with comparable safety profiles
EVERBUILD MITRE FAST Adhesive
---
Everbuild Stick 2 Superglue Debonder
---
Easy-Mix RK-7100 Structural Acrylic Adhesive Hardener
UFI: D960-4051-500A-4CHE
Loctite Power Grab Heavy Duty Express
---
Easy-Mix HT 180 Epoxy Adhesive Hardener
---
SEAL & BOND MS60
---
WEVO HARDENER 300
---
3M Scotch-Weld(TM) Plastic & Rubber Instant Adhesive PR20
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours or spray mist. Avoid exceeding the given occupational exposure limits. Do not get in eyes, on skin, or on clothing. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharge. Open drum carefully as content may be under pressure.
BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. Store in original container. Keep container tightly closed in a dry and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice. When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Keep away from heat/ sparks/ open flames/ hot surfaces. No smoking. Do not spray on a naked flame or any incandescent material. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Chemical-resistant, impervious gloves complying with an approved standard must be worn at all times when handling chemical products. Reference number EN 374. Follow manufacturer specifications. Suitable for short time use or protection against splashes: Butyl rubber/nitrile rubber gloves (0,4 mm). Contaminated gloves should be removed. Suitable for permanent exposure: Viton gloves (0.4 mm), breakthrough time >30 min.
Safety glasses with side-shields conforming to EN166
Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. organic vapor (Type A) and particulate filter A1: < 1000 ppm; A2: < 5000 ppm; A3: < 10000 ppm P1: Inert material; P2, P3: hazardous substances. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.
Protective clothing (e.g. Safety shoes acc. to EN ISO 20345, long-sleeved working clothing, long trousers).
Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable.
No dangerous reaction known under conditions of normal use.
Stable under recommended storage conditions.
Heat, flames and sparks.
No data available
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe way. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2
- Packing Group
- Not assigned by regulation
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No Chemical Safety Assessment has been carried out for this mixture by the supplier.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Everbuild Mitre Fast Activator?
The signal word is danger.
What is the physical form of Everbuild Mitre Fast Activator?
Everbuild Mitre Fast Activator is a aerosol appearing as aerosol with various color. It has no data available odor.
What is Everbuild Mitre Fast Activator used for?
Adhesive
What are the hazard statements for Everbuild Mitre Fast Activator?
This substance has 5 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: May burst if heated.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Everbuild Mitre Fast Activator?