NextSDS Logo
Ev

Everbuild Mitre Fast Activator

DANGER aerosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Everbuild Mitre Fast Activator

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Adhesive

Overview

Everbuild Mitre Fast Activator is a aerosol substance commonly used adhesive.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Skin Irrit. Category 2 H315
STOT SE Category 3 H336
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Do not pierce or burn, even after use.
  • P261: Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
  • P273: Avoid release to the environment.
  • P410 + P412: Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Everbuild – A Sika Company

undefined

Site 41 Knowsthorpe Way Cross Green Industrial Estate Leeds West Yorkshire LS9 0SW United Kingdom

GB

0113 240 3456

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

0044 113 240 3456

GB

(office hours only)

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane N/A 25-40% Hazardous
N,N-dimethyl-p-toluidine
EC: 202-805-4
99-97-8 0.25-1% Hazardous
petroleum gases, liquefied
EC: 270-704-2
68476-85-7 25-40% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Move to fresh air.

Symptoms:

May cause drowsiness or dizziness.

Skin Contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.

Symptoms:

Erythema, Dermatitis, irritant effects, Causes skin irritation.

Eye Contact

Remove contact lenses. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion/Swallowing

Do not induce vomiting without medical advice. Rinse mouth with water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.

Medical Treatment

Treat symptomatically.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Flammability
No data available
Solubility In Fat
Not available
Auto Ignition Temperature
No data available
Flash Point
-40 °C
Critical Property
Partition Coefficient
No data available
Physical State Data
aerosol
Metal Corrosion
Not available
Properties Status
Not available
State Under Standard Conditions
Not available
Bulk Density
Not available
Appearance
aerosol
Form
Not available
Upper Explosive Limit
7,4 %(V)
Evaporation Rate
No data available
Colour Intensity
Not available
Solubility In Water
No data available
Melting Point
No data available
Critical Property
Crystallisation Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Colour
various
Voc Content
Not available
Dynamic Viscosity
No data available
Molecular Weight
Not available
Softening Point
Not available
Boiling Point
No data available
Critical Property
Freezing Point
No data available
Lower Explosive Limit
1,1 %(V)
Vapor Pressure
34,6637 hPa
Decomposition Temperature
No data available
Odor
No data available
Ph
Not applicable
Density
0,67 g/cm3
Critical Property
Relative Evaporation Rate
Not available
Physical State
aerosol
Critical Property
Solubility
Not available
Kinematic Viscosity
Not applicable
Explosive Limits
Not available
Odor Threshold
No data available
Vapor Density
Not available
Relative Density
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Ensure adequate ventilation, especially in confined areas.

Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard must be worn at all times when handling chemical products. Reference number EN 374. Follow manufacturer specifications. Suitable for short time use or protection against splashes: Butyl rubber/nitrile rubber gloves (0,4 mm). Suitable for permanent exposure: Viton gloves (0.4 mm), breakthrough time >30 min.

Eye Protection

Safety glasses with side-shields conforming to EN166

Respiratory Protection

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. organic vapor (Type A) and particulate filter A1: < 1000 ppm; A2: < 5000 ppm; A3: < 10000 ppm P1: Inert material; P2, P3: hazardous substances. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.

Skin/Body Protection

Protective clothing (e.g. Safety shoes acc. to EN ISO 20345, long-sleeved working clothing, long trousers).

Environmental Exposure Controls

Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1950

Packing Group

Not assigned by regulation

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Everbuild Mitre Fast Activator?

The signal word for this substance is "danger".

What is the physical form of Everbuild Mitre Fast Activator?

Everbuild Mitre Fast Activator is a aerosol appearing as aerosol with various color. It has no data available odor.

What is Everbuild Mitre Fast Activator used for?

Adhesive

What are the hazard statements for Everbuild Mitre Fast Activator?

This substance has 5 hazard statements: H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated. H315: Causes skin irritation. H336: May cause drowsiness or dizziness. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Everbuild Mitre Fast Activator?

The melting point is No data available and the boiling point is No data available.