Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DAP Strong Anchoring Adhesive Part B Catalyst
- Product Code
- 070798281004
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive
Manufacturers & Suppliers
DAP Global Inc.
manufacturer
2400 Boston Street Suite 200 Baltimore, MD 21224-4723
888-327-8477
http://www.dap.com
Emergency Contacts
Medical/Poison Control
1-800-222-1222
Transportation/National Response Center
1-800-535-5053
Transportation/National Response Center
1-352-323-3500
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Glycerine | 56-81-5 | 30 - 60% | Yes |
| Benzoyl peroxide | 94-36-0 | 10 - 30% | No |
| Zinc stearate | 557-05-1 | 3 - 7% | No |
| Hydrated Magnesium Silicate | 63800-37-3 | 1 - 5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If you experience difficulty in breathing, leave the area to obtain fresh air.
In case of contact, wash skin immediately with soap and water.
In the case of contact with eyes, rinse immediately with plenty of water.
If swallowed do not induce vomiting.
Immediate Medical Attention
If continued difficulty is experienced, get medical attention immediately. Seek medical advice for eye contact. Seek immediate medical attention for ingestion.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog
Use water spray to cool exposed surfaces.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dike to prevent entering any sewer or waterway. Use personal protective equipment as necessary. Use absorbent material or scrape up dried material and place in container. Never discard in a liquid state. Dispose of material in accordance with all federal, state and local regulations.
No Information
Use absorbent material or scrape up dried material and place in container.
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
DAP Strong Anchoring Adhesive Part A Resin
---
DAP All Purpose Adhesive & Filler Part B Hardener
---
DAP Heavy Duty Construction Adhesive
---
DAP All Purpose Construction Adhesive
---
DAP All Purpose Adhesive & Filler Part A Resin
---
DAP RapidFuse Adhesive
---
DAP FRP Adhesive
---
DAP Foamboard Construction Adhesive
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Provide adequate ventilation. Avoid contact with eyes, skin and clothing.
Store away from caustics and oxidizers. Keep containers tightly closed.
Avoid contact with eyes, skin and clothing.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Excessive heat and freezing.
None under normal processing.
To avoid thermal decomposition, do not overheat.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3077
- Shipping Name
- Environmentally hazardous substance, solid, n.o.s.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DAP Strong Anchoring Adhesive Part B Catalyst?
The signal word is warning.
What is the physical form of DAP Strong Anchoring Adhesive Part B Catalyst?
DAP Strong Anchoring Adhesive Part B Catalyst is a solid appearing as black . It has characteristic odor.
What is DAP Strong Anchoring Adhesive Part B Catalyst used for?
Adhesive
What are the hazard statements for DAP Strong Anchoring Adhesive Part B Catalyst?
This substance has 1 hazard statement:
- H332: Harmful if inhaled.