Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PantaTec ULTIMATE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleaning additive

Uses advised against

No additional information available

Manufacturers & Suppliers

P

PantaTec GmbH

Max-Planck-Straße 15, D-33428 Marienfeld - Germany

+49 5734 51488 50

Emergency Contacts

National Poison Information Service (NPIS)

0844 892 0111

24 hour national number professionals only

National Health Service (NHS)

111

24 hour national number consumer

National Health Service (NHS)

0845 46 47

24 hour national number consumer

National Health Service (NHS)

call your local General Practitioner

Emergency Contact

999

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of silicate-complex listed with non-hazardous additives

Notes

This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex II.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing.

Skin contact

Wash skin with plenty of water. If skin irritation persists, take medical advice.

Symptoms: skin irritation

Eye contact

Rinse eyes with water as a precaution. Consult an ophthalmologist if irritation persists.

Ingestion

Call a poison center or a doctor if you feel unwell.

Immediate Medical Attention

Treat symptomatically.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, powder, carbon dioxide (CO2), water spray.

Unsuitable media

Strong water jet.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate spillage area.

Environmental

No special environmental precautions required.

Cleanup methods

Mechanically recover the product. Sweep up, shovel or vacuum.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation of the work station. Wear personal protective equipment. Avoid dust formation. Do not breathe dust.

Storage

Store in a well-ventilated place. Keep cool.

Hygiene

Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Hands

Chemically resistant protective gloves. EN 374. Gloves must be replaced after each use and whenever signs of wear or perforation appear. Apply emollient cream. Please follow the instructions related to the permeability and the penetration time provided by the manufacturer

Eyes

Safety glasses. In case of dust production: protective goggles

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. Breathing apparatus with filter. Filter type: P2

Skin/Body

Wear suitable protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
---
State Under Standard Conditions
---
Explosive Limits
---
Vapor Density
---
Boiling Point
No data available
Partition Coefficient
No data available
Upper Explosive Limit
Not applicable
Solubility
No data available
Voc Content
---
Solidification Point
---
Vapor Pressure
No data available
Decomposition Temperature
No data available
Dynamic Viscosity
No data available
Solubility In Fat
---
Ph
No data available
Colour Intensity
---
Solubility In Water
---
Flash Point
Not applicable
Softening Point
---
Freezing Point
Not applicable
Properties Status
---
Lower Explosive Limit
Not applicable
Physical State
Solid
Crystallisation Point
---
Odor
odourless.
Density
---
Relative Evaporation Rate
No data available
Bulk Density
---
Molecular Weight
---
Kinematic Viscosity
Not applicable
Evaporation Rate
---
Relative Density
Not applicable
Melting Point
≈ 1200 °C
Appearance
Powder.
Flammability
Non flammable
Cloud Point
---
Auto Ignition Temperature
Not applicable
Metal Corrosion
---
Odor Threshold
No data available
Colour
light blue.
Physical State Data
solid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions. To avoid thermal decomposition, do not overheat.

Reactivity

No additional information available.

Hazardous reactions

No dangerous reactions known under normal conditions of use.

Avoid

None under recommended storage and handling conditions (see section 7).

Incompatible

No additional information available

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of contents/container in accordance with licensed collector's sorting instructions. Disposal must be done according to official regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PantaTec ULTIMATE?

The signal word is no signal word.

What is the physical form of PantaTec ULTIMATE?

PantaTec ULTIMATE is a solid appearing as powder. with light blue. color. It has odourless. odor.

What is the solubility of PantaTec ULTIMATE?

No data available

What is PantaTec ULTIMATE used for?

Cleaning additive

What is the melting point of PantaTec ULTIMATE?

The melting point is ≈ 1200 °C and the boiling point is No data available.