NextSDS Logo
Safety Data Sheet EN

Benchmark ULTRA CC2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Benchmark ULTRA CC2
Product Code
05424542001

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

R

Roche Diagnostics Limited

manufacturer

Charles Avenue, Burgess Hill, RH15 9RY West Sussex

+44 1444 256000

Emergency Contacts

Emergency Contact

+49(0)621-759-2012

Emergency Contact

+49(0)621-759-4848

Emergency Contact

+49(0)8856-60-2629

Roche Diagnostics Ltd.

+44 1444 256500

Roche Diagnostics Ltd.

+44 7802 260498

Roche Diagnostics Ltd.

+44 1444 256561

Roche Diagnostics Ltd.

+44 7710 391653

NPIS

+44 844 892 0111

NHS Direct

+44 845 4647

NHS 24

+44 8454 242424

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2A

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P280 Wear eye protection/ face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical advice/ attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ethane-1,2-diol 107-21-1 5 - 10% Yes
sodium dodecyl sulphate 151-21-3 1 - 5% Yes
Citric acid monohydrate 5949-29-1 1 - 5% Yes
disodium disulphite 7681-57-4 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

If skin irritation persists, call a physician. If on skin, rinse well with water. If on clothes, remove clothes.

Eye contact

Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

No information available.

Instructions

Standard procedure for chemical fires.

Firefighter Protection

Wear self contained breathing apparatus for fire fighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Soak up with inert absorbent material.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Persons susceptible to skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.

Storage

Keep container tightly closed in a dry and well-ventilated place.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material: Protective gloves. Remarks: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eyes

Eye wash bottle with pure water, Tightly fitting safety goggles, Wear face-shield and protective suit for abnormal processing problems.

Skin/Body

impervious clothing, Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
6
Melting Point
no data available
Boiling Point
no data available
Flash Point
does not flash
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
The product is not flammable.
Upper Explosive Limit
no data available
Lower Explosive Limit
no data available
Explosive Limits
---
Auto Ignition Temperature
no data available
Decomposition Temperature
no data available
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No decomposition if stored and applied as directed.

Avoid

no data available

Incompatible

no data available

Decomposition

no data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company.

Disposal

Do not contaminate ponds, waterways or ditches with chemical or used container.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

OSHA Hazards: Harmful by ingestion., Toxic by skin absorption, Moderate skin irritant, Severe eye irritant, Moderate respiratory irritant. WHMIS Classification: D1B: Toxic Material Causing Immediate and Serious Toxic Effects, Toxic Material Causing Other Toxic Effects.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Benchmark ULTRA CC2?

The signal word is warning.

What is the physical form of Benchmark ULTRA CC2?

Benchmark ULTRA CC2 is a liquid appearing as liquid .

What are the hazard statements for Benchmark ULTRA CC2?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of Benchmark ULTRA CC2?

The melting point is no data available and the boiling point is no data available.