Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Spray Rusty Clear
- Product Code
- 34605
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant
Manufacturers & Suppliers
KENT (United Kingdom) Ltd
manufacturer
Forsyth House, Pitreavie Drive, Pitreavie Business Park, Dunfermline, Fife, KY11 8US
0800 136925
Emergency Contacts
KENT (United Kingdom) Ltd
+44 01383 723344
During normal office hours - Monday - Thursday 8.30am - 5.30pm, Friday 9.00am - 3.00pm
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of the substances listed below with harmless additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated light EC: 265-149-8 | 64742-47-8 | 25 - 50% | Yes |
| Petroleum gases, liquefied (contains less than 0.1 % w/w 1,3-butadiene (EINECS No 203-450-8)). EC: 270-704-2 | 68476-85-7 | 25 - 50% | Yes |
| White mineral oil (petroleum), light EC: 232-455-8 | 92062-35-6 | 5 - 15% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of symptoms.
Instantly wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water.
In case of persistent symptoms consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water haze. Fight larger fires with water haze or alcohol-resistant foam.
Water with a full water jet.
No further relevant information available.
Use fire fighting measures that suit the environment.
Firefighter Protection
Do not inhale explosion gases or combustion gases. Wear self-contained breathing apparatus. Wear full protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter drainage system, surface or ground water.
Send for recovery or disposal in suitable containers.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Keep away from heat and direct sunlight. Prevent formation of aerosols.
Store in cool location. Store in cool, dry conditions in well sealed containers. Protect from heat and direct sunlight.
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Wear suitable gloves tested to EN 374. Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: Value for the permeation: Level 6 > 480 minutes. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses (EN 166)
Only during spraying without adequate removal by suction. Filter AX (EN 14387)
Protective work clothing (EN-13034/6)
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known
Heat. Hot surfaces. Sources of ignition. Flames.
Strong acids and oxidizing agents
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
Must not be disposed of together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2
- Packing Group
- Void
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Spray Rusty Clear?
The signal word is danger.
What is the physical form of Spray Rusty Clear?
Spray Rusty Clear is a aerosol with dark yellow color. It has characteristic odor.
What is Spray Rusty Clear used for?
Lubricant
What are the hazard statements for Spray Rusty Clear?
This substance has 2 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: May burst if heated.
What is the melting point of Spray Rusty Clear?