NextSDS Logo
Sp

Spray Rusty Clear

DANGER Aerosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Spray Rusty Clear
Product Code
34605

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
FOR PROFESSIONAL AND INDUSTRIAL USE ONLY Lubricant

Overview

Spray Rusty Clear commonly used for professional and industrial use only lubricant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Pressurised container H229

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Do not pierce or burn, even after use.
  • P410 + P412: Protect from sunlight. Do not expose to temperatures exceeding 50C/122F.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

KENT (United Kingdom) Ltd

manufacturer

๐Ÿ“

Forsyth House Pitreavie Drive Pitreavie Business Park Dunfermline Fife KY11 8US

๐ŸŒ

GB

๐Ÿ“ž

0800 136925

๐Ÿ“ 

+44 1383 620079

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44 01383 723344

๐ŸŒ

GB

๐Ÿ•’

During normal office hours - Monday - Thursday 8.30am - 5.30pm, Friday 9.00am - 3.00pm

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of the substances listed below with harmless additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
HYDROCARBONS, C12 - C15, ALKANES
EC: 265-149-8
64742-47-8 25-50% โš ๏ธ Hazardous
Petroleum gases, liquified
EC: 270-704-2
68476-85-7 25-50% โš ๏ธ Hazardous
White mineral oil (petroleum), light
EC: 232-455-8
92062-35-6 5-15% โš ๏ธ Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air.

๐Ÿ–๏ธ Skin Contact

Instantly wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Aerosol
Critical Property
๐Ÿ“Š Physical State Data
aerosol
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Dark yellow
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Aerosol
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Mixture is non-soluble (in water).
๐ŸงŠ Melting Point
Not determined
Critical Property
๐Ÿ’จ Boiling Point
Not applicable, as aerosol
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable, as aerosol
Critical Property
๐Ÿ“Š Freezing Point
Not determined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable.
๐Ÿ’จ Vapor Pressure
720 kPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not determined
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not selfigniting.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Not miscible / difficult to mix
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
595g/l VOC
๐Ÿ“Š Metal Corrosion
Void
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Wear suitable gloves tested to EN 374. Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Value for the permeation: Level 6 > 480 minutes. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Safety glasses (EN 166)

๐Ÿ˜ท Respiratory Protection

Only during spraying without adequate removal by suction. Filter AX (EN 14387)

๐Ÿฆบ Skin/Body Protection

Protective work clothing (EN-13034/6)

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS, flammable

โš ๏ธ Transport Hazard Class

2.1

๐Ÿ“‹ Packing Group

Void

๐Ÿš› ADR Transport Precautions

Warning: Gases.

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Gases.

โœˆ๏ธ IATA Air Transport Precautions

Warning: Gases.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Spray Rusty Clear?

The signal word for this substance is "danger".

What is the physical form of Spray Rusty Clear?

Spray Rusty Clear is a aerosol with dark yellow color. It has characteristic odor.

What is Spray Rusty Clear used for?

FOR PROFESSIONAL AND INDUSTRIAL USE ONLY Lubricant

What are the hazard statements for Spray Rusty Clear?

This substance has 2 hazard statements: H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated.

What is the melting point of Spray Rusty Clear?

The melting point is Not determined and the boiling point is Not applicable, as aerosol.