NextSDS Logo
JR

JRCure 1055

WARNING SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
JRCure 1055
Chemical Name
BENZOYLFORMIATE DE MÉTHYLE
Synonyms
Methyl benzoylformate

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2120101338-67

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
Used for Photoinitiator etc.
Uses Advised Against
No information available.

Overview

JRCure 1055 (CAS: 15206-55-0 ) is a light yellow clear liquid substance commonly used used for photoinitiator etc..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P272: Contaminated work clothing must not be allowed out of the workplace.
  • P280: Wear protective gloves.
  • P302 + P352: IF ON SKIN: Wash with plenty of water/...
  • P321: Specific treatment (see ... on this label).
  • P362 + P364: Take off contaminated clothing and wash it before reuse.
  • P501: Dispose of contents/container to ... …in accordance with local/regional/national /international regulations (to be specified). Manufacturer/supplier or the competent authorityto specifywhether disposal requirements applyto contents, container or both.
  • If skin irritation or rash occurs: Get medical help.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

TIANJIN JIURI NEW MATERIALS CO., LTD

global supplier

C-5/6, Vision Hill,No.1 Gonghua Road, Huayuan Hi-tech Park, Tianjin, China.

CN

+86-22-23811185

+86-22-87186899

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+86-22-58330700

CN

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Methyl benzoylformate
EC: 239-263-3
15206-55-0 99% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention.

Skin Contact

Wash thoroughly with soap and water.

Eye Contact

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

Ingestion/Swallowing

Rinse mouth immediately and then drink plenty of water, seek medical attention.

Immediate Medical Attention Required

Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Water spray, dry powder, foam.

Unsuitable Extinguishing Media

Water jet.

Specific Fire Hazards

Combustible. Slight fire hazard when exposed to heat or flame. Heating may cause expansion or decomposition leading to violent rupture of containers. Harmful vapours. Evolution of fumes/fog.

Fire Fighting Instructions

Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. In case of fire in the surroundings, keep containers cool by spraying with water. Eliminate all ignition sources if safe to do so.

Firefighter Protection Equipment

As in any fire, wear self-contained breathing apparatus and full protective gear.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Remove all sources of ignition. Ensure adequate ventilation. Take precautionary measures against static discharges. Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak. Use personal protective equipment. Avoid breathing vapors and contacting with skin and eyes.

Large Spill Procedures

In case of large amount of spillage, contain a spill by bunding.

Environmental Precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Cleanup Methods

Absorb spilled material in dry sand or inert absorbent. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.

Cleanup Materials:

dry sand or inert absorbent

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Not available
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Light yellow clear liquid
Colour
Light yellow
Colour Intensity
Not available
Form
liquid
Odor
No information available
Odor Threshold
No information available
Ph
Not applicable
Melting Point
No information available
Critical Property
Boiling Point
252.8℃(101.325kPa)
Critical Property
Flash Point
126.5℃(1013 hPa) (closed cup)
Critical Property
Freezing Point
No information available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
No information available
Vapor Pressure
2.3Pa(20℃)
Vapor Density
No information available
Relative Density
1.161g/cm3(20℃)
Bulk Density
Not available
Density
Not available
Flammability
Non flammable
Upper Explosive Limit
No information available
Lower Explosive Limit
No information available
Explosive Limits
Not available
Auto Ignition Temperature
485°C at 1013 hPa
Decomposition Temperature
No information available
Solubility
Not available
Partition Coefficient
logKow(logPow): 1.9 at 23℃
Solubility In Water
2g/L(20 °C)
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
4.62 mPa.s (dynamic) (20 °C)
Kinematic Viscosity
Not available
Properties Status
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Handling is performed in a well ventilated place.

Wear suitable protective equipment.

Avoid contact with skin and eyes.

Avoid formation of dust.

Keep away from heat/sparks/open flames/ hot surfaces.

Storage Conditions

Keep containers tightly closed in a dry, cool and well-ventilated place.

Keep away from heat/sparks/open flames/ hot surfaces.

Store away from incompatible materials such as oxidizing agents and other incompatible materials.

Store away from foodstuff containers.

This substance may has crystallization phenomenon at low temperature, which is a normal phenomenon.

Fire Prevention Measures

Keep away from heat/sparks/open flames/ hot surfaces.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

1 Ensure adequate ventilation, especially in confined areas. 2 Ensure that eyewash stations and safety showers are close to the workstation location. 3 Use explosion-proof electrical/ventilating/lighting/equipment.

Hand Protection

Protective gloves (such as butyl rubber), approved by EN374(EU).

Eye Protection

Tightly fitting safety goggles (approved by EN166(EU) or NIOSH(US).

Respiratory Protection

Use appropriative respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: low boiling organic solvent, Type AX, Brown, conforming to EN371.

Skin/Body Protection

Wear fire/flame resistant/retardant clothing and antistatic boots.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable under proper operation and storage conditions.

Conditions to Avoid

High temperatures. Proximity to sources of ignition. Avoid electro-static discharge.

Incompatible Materials

Strong acids, strong bases, strong oxidizing agents.

Hazardous Decomposition Products

Carbon monoxide, toxic gases/vapours.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

Not regulated

Proper Shipping Name

Not regulated

Transport Hazard Class

Not regulated

Packing Group

Not regulated

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is JRCure 1055 known by?

JRCure 1055 is also known as: Methyl benzoylformate

What is the hazard signal word for JRCure 1055?

The signal word for this substance is "warning".

What is JRCure 1055 used for?

Used for Photoinitiator etc.

What are the hazard statements for JRCure 1055?

This substance has 1 hazard statements: H317: May cause an allergic skin reaction.

What is the melting point of JRCure 1055?

The melting point is No information available and the boiling point is 252.8℃(101.325kPa).