NextSDS Logo
Safety Data Sheet EN

JRCure 1055

CAS 15206-55-0
EC 239-263-3

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
JRCure 1055
Synonyms
Methyl benzoylformate

Regulatory Identifiers

CAS Number
15206-55-0 Check regulations →
EC Number
239-263-3 Check regulations →

Identified Uses

Used for Photoinitiator etc.

Uses advised against

No information available.

Manufacturers & Suppliers

T

TIANJIN JIURI NEW MATERIALS CO., LTD

manufacturer

C-5/6, Vision Hill, No.1 Gonghua Road, Huayuan Hi-tech Park, Tianjin, China. 300384

+86-22-23811185

Emergency Contacts

Emergency Contact

+86-22-58330700

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P272 Contaminated work clothing must not be allowed out of the workplace.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of water/...
P321 Specific treatment (see ... on this label).
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/container to ... ...in accordance with local/regional/national/international regulations (to be specified). Manufacturer/supplier or the competent authority to specify whether disposal requirements apply to contents, container or both.
If skin irritation or rash occurs: Get medical help.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Methyl benzoylformate EC: 239-263-3 15206-55-0 99% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention.

Skin contact

Wash thoroughly with soap and water.

Eye contact

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

Ingestion

Rinse mouth immediately and then drink plenty of water, seek medical attention.

Immediate Medical Attention

Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, dry powder, foam.

Unsuitable media

Water jet.

Specific hazards

Combustible. Slight fire hazard when exposed to heat or flame. Heating may cause expansion or decomposition leading to violent rupture of containers. Harmful vapours. Evolution of fumes/fog.

Instructions

Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method According to the surrounding situation is used. In case of fire in the surroundings, keep containers cool by spraying with water. Eliminate all ignition sources if safe to do so.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak. Use personal protective equipment. Avoid breathing vapors and contacting with skin and eyes.

Large spill

In case of large amount of spillage, contain a spill by bunding.

Environmental

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Cleanup methods

Absorb spilled material in dry sand or inert absorbent. Use spark-proof tools and explosion-proof equipment.

Materials: dry sand or inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling is performed in a well ventilated place. Wear suitable protective equipment. Avoid contact with skin and eyes. Avoid formation of dust. Keep away from heat/sparks/open flames/ hot surfaces.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat/sparks/open flames/ hot surfaces. Store away from incompatible materials such as oxidizing agents and other incompatible materials. Store away from foodstuff containers. This substance may has crystallization phenomenon at low temperature, which is a normal phenomenon.

Hygiene

Wear suitable protective equipment. Avoid contact with skin and eyes.

Fire prevention

Keep away from heat/sparks/open flames/ hot surfaces.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Use explosion-proof electrical/ventilating/lighting/equipment.

Hands

Protective gloves(such as butyl rubber), approved by EN374(EU).

Eyes

Tightly fitting safety goggles (approved by EN166(EU) or NIOSH(US).

Respiratory

Use appropriate respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: low boiling organic solvent, Type AX, Brown, conforming to EN371.

Skin/Body

Wear fire/flame resistant/retardant clothing and antistatic boots.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Light yellow clear liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Light yellow clear liquid
Colour
Light yellow
Colour Intensity
---
Form
liquid
Odor
No information available
Odor Threshold
No information available
Ph
Not applicable
Melting Point
No information available
Boiling Point
252.8°C (101.325kPa)
Flash Point
126.5°C (1013 hPa) (closed cup)
Freezing Point
No information available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available
Vapor Pressure
2.3Pa(20°C)
Vapor Density
No information available
Relative Density
1.161g/cm³ (20°C)
Bulk Density
---
Density
---
Flammability
Non flammable
Upper Explosive Limit
No information available
Lower Explosive Limit
No information available
Explosive Limits
---
Auto Ignition Temperature
485°C at 1013 hPa
Decomposition Temperature
No information available
Solubility
---
Partition Coefficient
log Kow (log Pow): 1.9 at 23°C
Solubility In Water
2 g/L (20 °C)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
4.62 mPa.s (20 °C)
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under proper operation and storage conditions.

Reactivity

No information available.

Hazardous reactions

No information available.

Avoid

Incompatible materials. High temperatures. Proximity to sources of ignition. Avoid electro-static discharge.

Incompatible

Strong acids, strong bases, strong oxidizing agents.

Decomposition

Carbon monoxide, toxic gases/vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

incineration

Disposal

Before disposal should refer to the relevant national and local laws and regulation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated
Shipping Name
Not regulated
Transport Class
Not regulated
Packing Group
Not regulated
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is JRCure 1055 known by?

JRCure 1055 is also known as: Methyl benzoylformate

What is the hazard signal word for JRCure 1055?

The signal word is warning.

What is the physical form of JRCure 1055?

JRCure 1055 is a light yellow clear liquid appearing as light yellow clear liquid with light yellow color. It has no information available odor.

What is JRCure 1055 used for?

Used for Photoinitiator etc.

What are the hazard statements for JRCure 1055?

This substance has 1 hazard statement:

  • H317: May cause an allergic skin reaction.

What is the melting point of JRCure 1055?

The melting point is No information available and the boiling point is 252.8°C (101.325kPa).