Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- JRCure 1104 (184)
Regulatory Identifiers
- CAS Number
- 947-19-3 Check regulations →
- EC Number
- 213-426-9 Check regulations →
- REACH No.
- 01-2119457404-40-0007
Identified Uses
F-1: Industrial formulation of preparations containing the Photoinitiator IW-2: Industrial use of the photoinitiator resulting in inclusion into a matrix, including application in coatings, adhesives, inks, fiber sizing PW-3: Wide dispersive indoor use (professional) of Photoinitiator resulting in inclusion into a matrix, including application in coatings, adhesives and inks.
Uses advised against
No uses advised against are identified.
Manufacturers & Suppliers
Chemical Inspection & Regulation Service Limited
TIANJIN JIURI NEW MATERIALS CO.,LTD.
manufacturer
5-6F, Building C, Vision Hill, No.1 Gonghua Road, Huayuan Hi-tech Park, Tianjin, China
+86-22-23811185
Emergency Contacts
Emergency Contact
+353 (1) 477 3710
9:00a.m.-17:30p.m.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydroxycyclohexyl phenyl ketone EC: 213-426-9 | 947-19-3 | 99.91% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If difficulties occur after dust has been inhaled, remove to fresh air and seek medical attention.
Wash thoroughly with soap and water.
Wash affected eyes for at least 15 minutes under running water with eyelids held open.
Rinse mouth and then drink plenty of water.
Immediate Medical Attention
If swallowed, inhalation or skin contact, get medical advice/attention.
Medical Treatment
Treat according to symptoms (decontamination, vital functions)
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry powder, foam.
Carbon dioxide.
Harmful vapours. Evolution of fumes/fog. The substances/groups of substances mentioned can be released in case of fire.
Firefighter Protection
Wear a self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stay in the windward. Immediately eliminate all sources of combustion such as flammable materials if it can be done without risk.
Pick up with suitable appliance and dispose of.
Contain with dust binding material and dispose of. Avoid raising dust.
Contain contaminated water/firefighting water. Do not discharge into drains/surface waters/groundwater.
Pick up with suitable appliance and dispose of.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Breathing must be protected when large quantities are decanted without local exhaust ventilation. Avoid inhalation of vapours.
Segregate from foodstuffs. Keep only in the original container. Keep container tightly closed. Protect from the effects of light. Avoid all sources of ignition: heat, sparks and open flame.
Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is recommended. Do not eat, drink or smoke when using. Wash hands after handling. Remove contaminated clothing and protective equipment before entering eating areas.
Avoid dust formation. Take precautionary measures against static discharges. Avoid all sources of ignition: heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide appropriate exhaust ventilation at machinery.
Chemical resistant protective gloves (EN 374). Suitable materials also with prolonged, direct contact (Recommended: Protective index 6, corresponding >480 minutes of permeation time according to EN 374): e.g. nitrile rubber (0.4 mm), chloroprene rubber (0.5 mm), polyvinylchloride (0.7 mm) and other. Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing. Manufacturer's directions for use should be observed because of great diversity of types.
Safety glasses with side-shields (frame goggles) (e.g. EN 166).
Suitable respiratory protection for lower concentrations or short-term effect: Particle filter with medium efficiency for solid and liquid particles (e.g. EN 143 or 149, Type P2 or FFP2).
Protective suit.
Avoid discharge into the environment. According to local regulations, Federal and official regulations.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended handling and storage conditions.
Stable under recommended handling and storage conditions.
No hazardous reactions when stored and handled according to instructions.
Incompatible materials. Temperatures above 35 °C (to maintain the technical properties of the product) and incompatible materials.
Strong acids, strong bases, strong oxidizing agents.
Carbon oxides, toxic gases/vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must be disposed of or incinerated in accordance with local regulations.
Must be disposed of or incinerated in accordance with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated
- Shipping Name
- Not regulated
- Transport Class
- Not regulated
- Packing Group
- Not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Employment restrictions concerning young person must be observed. For use only by technically qualified individuals.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for JRCure 1104 (184)?
The signal word is no signal word.
What is the physical form of JRCure 1104 (184)?
JRCure 1104 (184) is a solid at 20°c and 101.3 kpa with white color. It has characteristic odor.
What is JRCure 1104 (184) used for?
F-1: Industrial formulation of preparations containing the Photoinitiator IW-2: Industrial use of the photoinitiator resulting in inclusion into a matrix, including application in coatings, adhesives, inks, fiber sizing PW-3: Wide dispersive indoor use (professional) of Photoinitiator resulting in inclusion into a matrix, including application in coatings, adhesives and inks.
What are the hazard statements for JRCure 1104 (184)?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of JRCure 1104 (184)?
The melting point is 47.6 °C and the boiling point is 316.1 °C.