NextSDS Logo
Safety Data Sheet EN

FIXOLID

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FIXOLID
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Paint

Manufacturers & Suppliers

F

FILAgroup France

route de Marson 64, 51240 Saint Germain la Ville - France

03.26.69.26.26

Emergency Contacts

National Poisons Information Service (Birmingham Centre) City Hospital, Guy's & St Thomas' Hospital Trust

0844 892 0111

Monday to Friday, 08.00 to 18.00 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H226 Flammable liquid and vapour.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P261 Avoid breathing vapours, mist.
P312 Call a doctor, a POISON CENTER if you feel unwell.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
N-butyl acetate EC: 204-658-1 123-86-4 51 - 56% Yes
Titanium dioxide EC: 236-675-5 13463-67-7 0.2 - 7.5% No
carbon black EC: 215-609-9 1333-86-4 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move the affected person away from the contaminated area and into the fresh air. Get medical advice/attention if you feel unwell.

Symptoms: May cause drowsiness or dizziness.

Skin contact

Wash with water and soap as a precaution. If skin irritation occurs: Get medical advice/attention.

Symptoms: Prolonged or repeated contact may cause skin to become dry or cracked.

Eye contact

Rinse eyes with water as a precaution. In case of redness or irritation, call a doctor.

Symptoms: redness or irritation

Ingestion

Rinse mouth out with water. Do not induce vomiting. Get medical advice/attention.

Immediate Medical Attention

Get medical advice/attention if you feel unwell, if skin irritation occurs, or in case of redness or irritation of the eyes.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Dry powder. Carbon dioxide (CO2). Foam.

Unsuitable media

Do not use a heavy water stream.

Specific hazards

Flammable liquid and vapour. May form flammable/explosive vapour-air mixture.

Instructions

Cool down the containers exposed to heat with a water spray. Contain the extinguishing fluids by bunding.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes. Do not breathe vapours. In case of important spillage: Only qualified personnel equipped with suitable protective equipment may intervene.

Environmental

Contain the spilled material by bunding. Avoid release to the environment.

Cleanup methods

Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Wash non-recoverable remainder with large amounts of water.

Materials: inert solids, such as clay or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation of the work station. Avoid contact with skin and eyes. Do not breathe vapours. Avoid the build-up of electrostatic charge. Ground/bond container and receiving equipment. Do not smoke. No flames, no sparks. Eliminate all sources of ignition. Use explosion-proof equipment.

Storage

Keep in a cool, well-ventilated place away from heat. Protect from sunlight. Keep away from ignition sources. Keep container tightly closed.

Hygiene

Do not drink, eat or smoke in the workplace. Always wash hands after handling the product.

Fire prevention

Do not smoke. No flames, no sparks. Eliminate all sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Hands

Protective gloves. Breakthrough time (min) : >= 480

Eyes

Protective goggles

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment

Skin/Body

Protective clothing

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Variable.
Colour Intensity
---
Form
---
Odor
n-butyl acetate.
Odor Threshold
Not established
Ph
No data available
Melting Point
No data available
Boiling Point
> 100 °C
Flash Point
< 60 °C
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
No data available
Evaporation Rate
---
Vapor Pressure
10.7 hPa
Vapor Density
---
Relative Density
1 - 1.2
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
7.5 vol %
Lower Explosive Limit
1.2 vol %
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
Poorly soluble in water.
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
47.1 %
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at ambient temperature and under normal conditions of use.

Reactivity

Flammable liquid and vapour.

Hazardous reactions

Flammable or explosive vapour/air mixtures may be formed.

Avoid

High temperature.

Incompatible

Strong oxidizing agents. Strong acids. Strong bases.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with relevant local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
PAINT (N-butyl acetate)
Transport Class
3
Packing Group
III
ADR

Classification code (ADR): F1. Packing instructions (ADR): P001, IBC03, LP01, R001. Special packing provisions (ADR): PP1. Mixed packing provisions (ADR): MP19. Portable tank and bulk container instructions (ADR): T2. Portable tank and bulk container special provisions (ADR): TP1, TP29. Tank code (ADR): LGBF. Vehicle for tank carriage: FL. Special provisions for carriage - Packages (ADR): V12. Special provisions for carriage - Operation (ADR): S2. EAC code: •3YE

IMDG

163, 223, 367, 955

IATA

PCA Excepted quantities (IATA): E1. PCA Limited quantities (IATA): Y344. PCA limited quantity max net quantity (IATA): 10L. PCA packing instructions (IATA): 355. PCA max net quantity (IATA): 60L. CAO packing instructions (IATA): 366. CAO max net quantity (IATA): 220L. ERG code (IATA): 3L

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FIXOLID?

The signal word is warning.

What is the physical form of FIXOLID?

FIXOLID is a liquid with variable. color. It has n-butyl acetate. odor.

What is the solubility of FIXOLID?

Poorly soluble in water.

What is FIXOLID used for?

Paint

What are the hazard statements for FIXOLID?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H336: May cause drowsiness or dizziness.

What is the melting point of FIXOLID?

The melting point is No data available and the boiling point is > 100 °C.