NextSDS Logo
Safety Data Sheet EN

ECO Disinfect

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ECO Disinfect
Product Code
74492

Regulatory Identifiers

CAS Number
N/A

Identified Uses

desinfection of whirlpoolwater

Manufacturers & Suppliers

R

Rudolf Koller GmbH

national supplier

Rudolf-Koller-Straße 1, A-3902 Vitis Niederösterreich

Emergency Contacts

Poison control center of „Gesundheit Österreich GmbH“

+43 1 406 43 43

Rudolf Koller GmbH

+43 2841 8207

Mo-Fr 8:00-16:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

aqueous solution of following non rated First Aid components

Chemical Name CAS Number Concentration Hazardous
active Chlorine from Sodium-chloride by electrolysis EC: 231-668-3 7681-52-9 0.01 - 0.1% Yes
Sodiumchloride EC: 231-598-3 7647-14-5 0.1 - 1% No

max. MAK-values chapter 8 dermatologically tested, no skin change HET-CAM Test 0

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

after irritation, bring the affected person into the fresh air.

Skin contact

flush with plenty of water

Eye contact

after irritation spill eyes careful

Ingestion

wash out mouth thoroughly and drink a large amount of water

Medical Treatment

Treat symptomatically, let show Safety data sheet

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The product itself is not flammable. Choose fire-fighting measures suitable for environment fire

Specific hazards

Traces of chlorine gas can occur

Instructions

no special additional measures

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Follow the usual caution measures while dealing with chemicals. No special measures

Environmental

After release to the environment flush with plenty of water

Cleanup methods

Absorb with liquid binding material and dispose of it properly.

Materials: liquid binding material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

During filling and pouring wear protective glasses

Storage

keep only in the original container, keep container tightly closed, protect from frost and direct sunlight; recommended storage temperature is +5°C to +25°C

Fire prevention

product does not combust and does not explode

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Care for a good ventilation in the working room

Hands

not relevant

Eyes

wear protective goggles

Respiratory

not necessary

Skin/Body

not relevant

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
---
Crystallisation Point
---
Density
---
Solubility In Water
fully miscible
Physical State
liquid
Colour
colourless
Melting Point
about -2°C
Properties Status
---
Evaporation Rate
data are not available
Softening Point
---
Explosive Limits
---
Physical State Data
liquid
Solidification Point
---
Ph
6,0-8,0
Vapor Pressure
data are not available
Freezing Point
---
Upper Explosive Limit
not applicable
Lower Explosive Limit
not applicable
Kinematic Viscosity
---
Odor
faint smell like swimming-pool water
Boiling Point
ca. 100°C
Dynamic Viscosity
---
Voc Content
---
Molecular Weight
---
Relative Density
ca. 1,004 g/l
State Under Standard Conditions
liquid behaves like water
Relative Evaporation Rate
---
Decomposition Temperature
no self-ignition
Bulk Density
---
Auto Ignition Temperature
incombustible
Solubility In Fat
---
Flash Point
not applicable
Odor Threshold
data is not available
Solubility
---
Colour Intensity
---
Metal Corrosion
aqueous solution < 10% not more corrosive than water
Cloud Point
---
Vapor Density
---
Appearance
clear, colourless liquid
Flammability
incombustible
Form
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

stabile under the specified storage conditions

Reactivity

none known when used in accordance to instructions

Hazardous reactions

reacts with acids, strong oxidising effect

Avoid

protected from heat and direct sunlight

Incompatible

not passivated unprotected metals, acids

Decomposition

none known when used in accordance to instructions; thermal decomposition: formation of sodium chlorate

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

reduction with sodium thiosulfate or sodium, sulfite

Disposal

waste disposal according to official regulations

Waste Codes

20-03-99 urban waste EWC
15-01-02 Plastic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
lapse
Shipping Name
lapse
Transport Class
lapse
Packing Group
lapse
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ECO Disinfect?

The signal word is no signal word.

What is the physical form of ECO Disinfect?

ECO Disinfect is a liquid appearing as clear, colourless liquid with colourless color. It has faint smell like swimming-pool water odor.

What is ECO Disinfect used for?

desinfection of whirlpoolwater

What is the melting point of ECO Disinfect?

The melting point is about -2°C and the boiling point is ca. 100°C.