Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ZEP CONCENTRATED GLASS CLEANER 5GL
- Product Code
- 000000000000105235
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Zep Inc.
manufacturer
350 Joe Frank Harris Parkway, SE Emerson, GA 30137
877-428-9937
Emergency Contacts
Emergency Contact
877-541-2016
CHEMTREC
800-424-9300
CHEMTREC
202-483-7616
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician. Move to fresh air.
Remove contaminated clothing and shoes. If symptoms persist, call a physician. Wash clothing before reuse. Wash off immediately with plenty of water for at least 15 minutes.
Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Symptoms: Causes serious eye irritation.
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. DO NOT induce vomiting unless directed to do so by a physician or poison control center.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical, Water spray
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. Use a water spray to cool fully closed containers.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains, inform respective authorities.
collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).
Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
ZEP FAST 505 DEGREASER & CLEANER_1GL_4CT
---
QC 50 ULTRA CONCENTRATED GLASS CLEANER
---
GLASS CLEANER, 500 mL
---
ZEP SPRAY MOP REFILL & FLOOR CLEANER_1GL_4CT
---
ZEP FOAMING WALL CLEANER 20N18_12CT
---
ZEP INSTANT HAND SANITIZER GEL 70% 500ML 12CT
---
up & up Glass Cleaner
---
CITRUS CLEANER CONCENTRATED
UFI: HXR2-H0KP-0002-J61X
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid formation of aerosol. Do not breathe vapours or spray mist. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Open drum carefully as content may be under pressure. Dispose of rinse water in accordance with local and national regulations.
No smoking. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.
Smoking, eating and drinking should be prohibited in the application area.
No smoking. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
effective ventilation in all processing areas
Material: Protective gloves. Remarks: The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Safety glasses. Access to clean water to rinse eyes must be available, options include: eye wash stations or showers, or eye wash bottles with pure water.
Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines.
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable
Vapours may form explosive mixture with air. No decomposition if stored and applied as directed.
Heat, flames and sparks.
Oxidizing agents
Carbon dioxide (CO2) Carbon monoxide Nitrogen oxides (NOx) Sulphur oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- FLAMMABLE LIQUID, N.O.S.
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ZEP CONCENTRATED GLASS CLEANER 5GL?
The signal word is warning.
What is the physical form of ZEP CONCENTRATED GLASS CLEANER 5GL?
ZEP CONCENTRATED GLASS CLEANER 5GL is a liquid appearing as liquid with blue, clear color. It has characteristic odor.
What are the hazard statements for ZEP CONCENTRATED GLASS CLEANER 5GL?
This substance has 4 hazard statements:
- H226: Flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H373: May cause damage to organs through prolonged or repeated exposure if inhaled.
What is the melting point of ZEP CONCENTRATED GLASS CLEANER 5GL?
The melting point is No data available and the boiling point is 100 °C.