Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SPECTRASYN 6
- Product Code
- 52509
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Base Oil
Uses advised against
Use only for intended applications.
Manufacturers & Suppliers
Univar Solutions UK Ltd
Aquarius House 6 Mid Point Business Park Bradford BD3 7AY
+44 1274 267300
Emergency Contacts
SGS
+32 (0)3 575 55 55
24h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
SECTION 3: Composition/information on ingredients
<!-- PAGE 2 --> Revision date: 16/02/2022 Version number: 2.000 Supersedes date: 14/09/2017 # SPECTRASYN 6 ##
Notes
The data shown are in accordance with the latest EC Directives.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Rinse nose and mouth with water. Get medical attention if symptoms are severe or persist. When breathing is difficult, properly trained personnel may assist affected person by administering oxygen. If breathing stops, provide artificial respiration. Get medical attention immediately.
Symptoms: Symptoms are severe or persist, breathing is difficult, breathing stops.
After contact with skin, take off immediately all contaminated clothing, and wash immediately with plenty of water. Get medical attention if symptoms are severe or persist after washing. If product is injected into or under skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.
Symptoms: Symptoms are severe or persist after washing. Initial symptoms from high pressure injection may be minimal or absent.
Rinse immediately with plenty of water. Remove any contact lenses and open eyelids wide apart. Continue to rinse for at least 15 minutes. Get medical attention if any discomfort continues.
Symptoms: May cause temporary eye irritation. Any discomfort continues.
Rinse mouth thoroughly with water. Do not induce vomiting. Get medical attention if any discomfort continues.
Symptoms: Any discomfort continues.
Immediate Medical Attention
Get medical attention if symptoms are severe or persist, or if any discomfort continues. Get medical attention immediately if breathing stops. If product is injected into or under skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. If in doubt, get medical attention promptly.
Medical Treatment
Treat symptomatically. Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury for skin injection.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Extinguish with alcohol-resistant foam, carbon dioxide, dry powder or water fog.
Do not use water jet as an extinguisher, as this will spread the fire.
When heated and in case of fire, toxic vapours/gases may be formed.
No action shall be taken without appropriate training or involving any personal risk. Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk.
Firefighter Protection
No action shall be taken without appropriate training or involving any personal risk. Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk. Control run-off water by containing and keeping it out of sewers and watercourses. Contain and collect extinguishing water. Evacuate area. Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Follow precautions for safe handling described in this safety data sheet. Keep unnecessary and unprotected personnel away from the spillage. Do not touch or walk into spilled material. Stop leak if safe to do so.
Do not discharge into drains or watercourses or onto the ground. Spillages or uncontrolled discharges into watercourses must be reported immediately to the Environmental Agency or other appropriate regulatory body.
Collect and place in suitable waste disposal containers and seal securely. Clean contaminated objects and areas thoroughly, observing environmental regulations. Label the containers containing waste and contaminated materials and remove from the area as soon as possible.
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Provide adequate ventilation. Wear protective clothing as described in Section 8 of this safety data sheet. Follow precautions for safe handling described in this safety data sheet. Avoid inhalation of vapours and contact with skin and eyes. Take care as floors and other surfaces may become slippery. Product is a static accumulator Take precautionary measures against static discharges. Ground/bond container and receiving equipment. Earth container and transfer equipment to eliminate sparks from static electricity.
Store in tightly-closed, original container in a dry, cool and well-ventilated place. Only store in correctly labelled containers. Product is a static accumulator
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. As this product contains ingredients with exposure limits, process enclosures, local exhaust ventilation or other engineering controls should be used to keep worker exposure below any statutory or recommended limits, if use generates dust, fumes, gas, vapour or mist.
Chemical-resistant, impervious gloves complying with an approved standard should be worn if a risk assessment indicates skin contact is possible. The most suitable glove should be chosen in consultation with the glove supplier/manufacturer, who can provide information about the breakthrough time of the glove material. To protect hands from chemicals, gloves should comply with European Standard EN374.
Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible. The following protection should be worn: Tight-fitting safety glasses. Personal protective equipment for eye and face protection should comply with European Standard EN166.
No specific requirements are anticipated under normal conditions of use. Respiratory protection complying with an approved standard should be worn if a risk assessment indicates inhalation of contaminants is possible. Ensure all respiratory protective equipment is suitable for its intended use and is 'CE'-marked. If ventilation is inadequate, suitable respiratory protection must be worn. EN 136/140/141/145/143/149
Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal ambient temperatures and when used as recommended.
See the other subsections of this section for further details.
Will not polymerise.
Avoid excessive heat for prolonged periods of time. Avoid heat, flames and other sources of ignition. Product is a static accumulator Take precautionary measures against static discharges.
Strong oxidising agents.
Does not decompose when used and stored as recommended. Thermal decomposition or combustion may liberate carbon oxides and other toxic gases or vapours. Oxides of the following substances: Carbon.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable.
- Shipping Name
- Not applicable.
- Transport Class
- No transport warning sign required.
- Packing Group
- Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SPECTRASYN 6?
The signal word is no signal word.
What is the physical form of SPECTRASYN 6?
SPECTRASYN 6 is a liquid. appearing as liquid. with clear. colourless. color. It has odourless. odor.
What is the solubility of SPECTRASYN 6?
Insoluble in water.
What is SPECTRASYN 6 used for?
Base Oil
What are the hazard statements for SPECTRASYN 6?
This substance has 1 hazard statement:
- Not Classified
What is the melting point of SPECTRASYN 6?
The melting point is -50°C and the boiling point is No information available..