NextSDS Logo
Safety Data Sheet EN

SPECTRASYN 6

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SPECTRASYN 6
Product Code
52509

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Base Oil

Uses advised against

Use only for intended applications.

Manufacturers & Suppliers

U

Univar Solutions UK Ltd

national supplier

Aquarius House, 6 Mid Point Business Park, Bradford, BD3 7AY

+44 1274 267300

Emergency Contacts

SGS

+32 (0)3 575 55 55

24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified
Not Classified
Not Classified

GHS Pictograms

Hazard Statements

NC Not Classified

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

SECTION 3: Composition/information on ingredients

<!-- PAGE 2 --> Revision date: 16/02/2022 Version number: 2.000 Supersedes date: 14/09/2017 # SPECTRASYN 6 ##

Notes

The data shown are in accordance with the latest EC Directives.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Rinse nose and mouth with water. Get medical attention if symptoms are severe or persist. When breathing is difficult, properly trained personnel may assist affected person by administering oxygen. If breathing stops, provide artificial respiration. Get medical attention immediately.

Skin contact

After contact with skin, take off immediately all contaminated clothing, and wash immediately with plenty of water. Get medical attention if symptoms are severe or persist after washing. If product is injected into or under skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

Symptoms: If product is injected into or under skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

Eye contact

Rinse immediately with plenty of water. Remove any contact lenses and open eyelids wide apart. Continue to rinse for at least 15 minutes. Get medical attention if any discomfort continues.

Symptoms: May cause temporary eye irritation.

Ingestion

Rinse mouth thoroughly with water. Do not induce vomiting. Get medical attention if any discomfort continues.

Immediate Medical Attention

If product is injected into or under skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Extinguish with alcohol-resistant foam, carbon dioxide, dry powder or water fog.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

When heated and in case of fire, toxic vapours/gases may be formed.

Instructions

No action shall be taken without appropriate training or involving any personal risk. Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk. Evacuate area.

Firefighter Protection

Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if safe to do so.

Environmental

Do not discharge into drains or watercourses or onto the ground.

Cleanup methods

Absorb spillage with non-combustible, absorbent material. Collect and place in suitable waste disposal containers and seal securely.

Materials: non-combustible, absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide adequate ventilation. Wear protective clothing as described in Section 8 of this safety data sheet. Follow precautions for safe handling described in this safety data sheet. Avoid inhalation of vapours and contact with skin and eyes. Take care as floors and other surfaces may become slippery.

Storage

Store in tightly-closed, original container in a dry, cool and well-ventilated place. Only store in correctly labelled containers. Product is a static accumulator.

Fire prevention

Product is a static accumulator. Take precautionary measures against static discharges. Ground/bond container and receiving equipment. Earth container and transfer equipment to eliminate sparks from static electricity.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation. As this product contains ingredients with exposure limits, process enclosures, local exhaust ventilation or other engineering controls should be used to keep worker exposure below any statutory or recommended limits, if use generates dust, fumes, gas, vapour or mist.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn if a risk assessment indicates skin contact is possible. The most suitable glove should be chosen in consultation with the glove supplier/manufacturer, who can provide information about the breakthrough time of the glove material. To protect hands from chemicals, gloves should comply with European Standard EN374.

Eyes

Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible. The following protection should be worn: Tight-fitting safety glasses. Personal protective equipment for eye and face protection should comply with European Standard EN166.

Respiratory

No specific requirements are anticipated under normal conditions of use. Respiratory protection complying with an approved standard should be worn if a risk assessment indicates inhalation of contaminants is possible. Ensure all respiratory protective equipment is suitable for its intended use and is 'CE'-marked. If ventilation is inadequate, suitable respiratory protection must be worn. EN 136/140/141/145/143/149

Skin/Body

Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
Odourless.
Crystallisation Point
---
Partition Coefficient
>3.5
Solubility In Fat
---
Vapor Density
No information available.
Evaporation Rate
No information available.
Explosive Limits
---
Colour
Clear. Colourless.
Relative Density
0.83 @ 15°C
Melting Point
-50°C
Upper Explosive Limit
No information available.
Molecular Weight
No information available.
Odor Threshold
No information available.
Metal Corrosion
---
Kinematic Viscosity
30 cSt @ 40°C 6 cSt @ 100°C
Density
---
Decomposition Temperature
No information available.
Form
---
Solubility In Water
Insoluble in water.
Appearance
Liquid. Clear. Colourless.
Properties Status
---
Relative Evaporation Rate
---
Dynamic Viscosity
---
Softening Point
---
State Under Standard Conditions
---
Boiling Point
No information available.
Vapor Pressure
<0.013 kPa @ 20°C
Lower Explosive Limit
No information available.
Flash Point
>230°C/446°F
Bulk Density
No information available.
Colour Intensity
---
Physical State
Liquid.
Physical State Data
liquid
Solubility
Insoluble in water.
Cloud Point
---
Solidification Point
---
Voc Content
No information available.
Ph
No information available.
Freezing Point
No information available.
Auto Ignition Temperature
No information available.
Flammability
No information available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal ambient temperatures and when used as recommended.

Reactivity

See the other subsections of this section for further details.

Hazardous reactions

Will not polymerise.

Avoid

Avoid excessive heat for prolonged periods of time. Avoid heat, flames and other sources of ignition. Product is a static accumulator Take precautionary measures against static discharges.

Incompatible

Strong oxidising agents.

Decomposition

Does not decompose when used and stored as recommended. Thermal decomposition or combustion may liberate carbon oxides and other toxic gases or vapours. Oxides of the following substances: Carbon.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Waste should be treated as controlled waste.

Disposal

Dispose of waste to licensed waste disposal site in accordance with the requirements of the local Waste Disposal Authority.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable.
Shipping Name
Not applicable.
Transport Class
No transport warning sign required.
Packing Group
Not applicable.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SPECTRASYN 6?

The signal word is no signal word.

What is the physical form of SPECTRASYN 6?

SPECTRASYN 6 is a liquid. appearing as liquid. clear. colourless. with clear. colourless. color. It has odourless. odor.

What is the solubility of SPECTRASYN 6?

Insoluble in water.

What is SPECTRASYN 6 used for?

Base Oil

What are the hazard statements for SPECTRASYN 6?

This substance has 1 hazard statement:

  • NC Not Classified

What is the melting point of SPECTRASYN 6?

The melting point is -50°C and the boiling point is No information available..