NextSDS Logo
Safety Data Sheet EN

SPECTRASYN™ 10

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SPECTRASYN™ 10

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Distribution of substance Formulation and (re)packing of substances and mixtures Lubricants - Industrial Metal working fluids / rolling oils - Industrial Functional Fluids - Industrial Lubricants - Professional (Low Release) Lubricants - Professional (High Release) Metal working fluids / rolling oils - Professionals Metal working fluids / rolling oils - Professional Functional Fluids - Professional Lubricants - Consumer (Low Release) Functional Fluids - Consumer

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

E

ExxonMobil Petroleum & Chemical BV on behalf of MOBIL CHEMICAL PRODUCTS INTERNATIONAL INC.

manufacturer

SYNTHETICS DEPARTMENT HERMESLAAN 2 B-1831 MACHELEN Belgium

+32-2-239 3111

Emergency Contacts

CHEMTREC

+(44)-8708200418

24 Hour

National Poison Control Centre

111

National Poison Control Centre

(+353)1 809 2166

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No Hazardous Substance(s) required for disclosure.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water.

Symptoms: minimal or absent (initial symptoms from high pressure injection)

Eye contact

Flush thoroughly with water.

Symptoms: irritation

Ingestion

First aid is normally not required.

Symptoms: discomfort

Immediate Medical Attention

If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. If irritation occurs, get medical assistance. Seek medical attention if discomfort occurs.

Medical Treatment

Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight streams of water

Specific hazards

Incomplete combustion products, Oxides of carbon, Smoke, Fume

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with spilled material.

Large spill

Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.

Materials: suitable absorbent, booms

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent small spills and leakage to avoid slip hazard. Use proper bonding and/or earthing procedures.

Storage

The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present. Use proper bonding and/or earthing procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

No protection is ordinarily required under normal conditions of use.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Clear
Odor
Mild
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
>250°C (482°F) [ASTM D-93]
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
< 0.013 kPa (0.1 mm Hg) at 20 °C [In-house method]
Vapor Density
No data available
Relative Density
0.84 [In-house method]
Bulk Density
---
Density
---
Flammability
Not technically feasible
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
Negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
68 cSt (68 mm2/sec) at 40°C | 10 cSt (10 mm2/sec) at 100°C [In-house method]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. TOXICITY

Material -- Not expected to be harmful to aquatic organisms.

12.2. PERSISTENCE AND DEGRADABILITY

Biodegradation: Material -- Expected to be inherently biodegradable

12.3. BIOACCUMULATIVE POTENTIAL

Not determined.

12.4. MOBILITY IN SOIL

Not determined.

12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)

Material does not meet the Reach Annex XIII criteria for PBT or vPvB.

The material does not meet the criteria for PBT or vPvB as defined in REACH Annex XIII.

12.6. OTHER ADVERSE EFFECTS

No adverse effects are expected.

No adverse effects are expected.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Disposal

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Waste Codes

13 02 06* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Applicable EU Directives and Regulations: 1907/2006 and 1272/2008

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SPECTRASYN™ 10?

The signal word is no signal word.

What is the physical form of SPECTRASYN™ 10?

SPECTRASYN™ 10 is a liquid with colourless color. It has mild odor.

What is SPECTRASYN™ 10 used for?

Distribution of substance Formulation and (re)packing of substances and mixtures Lubricants - Industrial Metal working fluids / rolling oils - Industrial Functional Fluids - Industrial Lubricants - Professional (Low Release) Lubricants - Professional (High Release) Metal working fluids / rolling oils - Professionals Metal working fluids / rolling oils - Professional Functional Fluids - Professional Lubricants - Consumer (Low Release) Functional Fluids - Consumer

What is the melting point of SPECTRASYN™ 10?

The melting point is No data available and the boiling point is No data available.