Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SPECTRASYN™ 10
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Distribution of substance Formulation and (re)packing of substances and mixtures Lubricants - Industrial Metal working fluids / rolling oils - Industrial Functional Fluids - Industrial Lubricants - Professional (Low Release) Lubricants - Professional (High Release) Metal working fluids / rolling oils - Professionals Metal working fluids / rolling oils - Professional Functional Fluids - Professional Lubricants - Consumer (Low Release) Functional Fluids - Consumer
Uses advised against
None unless specified elsewhere in this SDS.
Manufacturers & Suppliers
ExxonMobil Petroleum & Chemical BV on behalf of MOBIL CHEMICAL PRODUCTS INTERNATIONAL INC.
manufacturer
SYNTHETICS DEPARTMENT HERMESLAAN 2 B-1831 MACHELEN Belgium
+32-2-239 3111
Emergency Contacts
CHEMTREC
+(44)-8708200418
24 Hour
National Poison Control Centre
111
National Poison Control Centre
(+353)1 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No Hazardous Substance(s) required for disclosure.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness
Wash contact areas with soap and water.
Symptoms: minimal or absent (initial symptoms from high pressure injection)
Flush thoroughly with water.
Symptoms: irritation
First aid is normally not required.
Symptoms: discomfort
Immediate Medical Attention
If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. If irritation occurs, get medical assistance. Seek medical attention if discomfort occurs.
Medical Treatment
Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight streams of water
Incomplete combustion products, Oxides of carbon, Smoke, Fume
Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled material.
Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
Prevent entry into waterways, sewers, basements or confined areas.
Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.
Materials: suitable absorbent, booms
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent small spills and leakage to avoid slip hazard. Use proper bonding and/or earthing procedures.
The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.
Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present. Use proper bonding and/or earthing procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
No protection is ordinarily required under normal conditions of use.
If contact is likely, safety glasses with side shields are recommended.
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Excessive heat. High energy sources of ignition.
Strong oxidisers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
12.2. PERSISTENCE AND DEGRADABILITY
12.3. BIOACCUMULATIVE POTENTIAL
12.4. MOBILITY IN SOIL
12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)
The material does not meet the criteria for PBT or vPvB as defined in REACH Annex XIII.
12.6. OTHER ADVERSE EFFECTS
No adverse effects are expected.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Applicable EU Directives and Regulations: 1907/2006 and 1272/2008
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SPECTRASYN™ 10?
The signal word is no signal word.
What is the physical form of SPECTRASYN™ 10?
SPECTRASYN™ 10 is a liquid with colourless color. It has mild odor.
What is SPECTRASYN™ 10 used for?
Distribution of substance Formulation and (re)packing of substances and mixtures Lubricants - Industrial Metal working fluids / rolling oils - Industrial Functional Fluids - Industrial Lubricants - Professional (Low Release) Lubricants - Professional (High Release) Metal working fluids / rolling oils - Professionals Metal working fluids / rolling oils - Professional Functional Fluids - Professional Lubricants - Consumer (Low Release) Functional Fluids - Consumer
What is the melting point of SPECTRASYN™ 10?
The melting point is No data available and the boiling point is No data available.