NextSDS Logo
Safety Data Sheet EN

SPECTRASYN 100

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SPECTRASYN 100
Product Code
6021653-01

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Base oil

Manufacturers & Suppliers

E

EXXONMOBILCHEMICAL BELGIUM ON BEHALF OF MOBIL CHEMICAL PRODUCTS INTERNATIONAL, INC.

SYNTHETICS DEPARTMENT HERMESLAAN 2 B-1831 MACHELEN Belgium

(32) 2 722 3650

Emergency Contacts

Emergency Contact

02380 891 558

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

GHS Pictograms

GHS06 - Acute toxicity

GHS06

Hazard Statements

H310 High-pressure injection under skin may cause serious damage.
H313 Low order of toxicity.
NOTE: This material should not be used for any other purpose than the intended use in Section 1 without expert advice. Health studies have shown that chemical exposure may cause potential human health risks which may vary from person to person.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

No Reportable Hazardous Substance(s) or Complex Substance(s).

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Symptoms: initial symptoms from high pressure injection may be minimal or absent

Eye contact

Flush thoroughly with water.

Symptoms: irritation

Ingestion

First aid is normally not required. Seek medical attention if discomfort occurs.

Symptoms: discomfort

Immediate Medical Attention

If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Medical Treatment

Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury (for high pressure injection).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight streams of water

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Large spill

Dyke far ahead of liquid spill for later recovery and disposal.

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures.

Storage

Do not store in open or unlabelled containers.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or earthing procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

No protection is ordinarily required under normal conditions of use.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No protection is ordinarily required under normal conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear and Bright
Colour
Clear and Bright
Colour Intensity
---
Form
Viscous
Odor
Odourless
Odor Threshold
N/D
Ph
---
Melting Point
---
Boiling Point
N/D
Flash Point
288°C (550°F) [ASTM D-93]
Freezing Point
N/D
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
N/D
Vapor Pressure
< 0.013 kPa (0.1 mm Hg) at 20 °C
Vapor Density
N/D
Relative Density
0.855
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
N/D
Lower Explosive Limit
N/D
Explosive Limits
---
Auto Ignition Temperature
N/D
Decomposition Temperature
---
Solubility
---
Partition Coefficient
N/D
Solubility In Water
Negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
1300 cSt (1300 mm2/sec) at 40°C | 104 cSt (104 mm2/sec) at 100°C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Hazardous reactions

Will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

ECOTOXICITY

Material -- Not expected to be harmful to aquatic organisms.

Not expected to be harmful to aquatic organisms.

PERSISTENCE AND DEGRADABILITY

Biodegradation: Material -- Expected to biodegrade slowly.

Expected to biodegrade slowly.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures

Disposal

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Waste Codes

13 02 06* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Material is not dangerous as defined by the EU Dangerous Substances/Preparations Directives.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SPECTRASYN 100?

The signal word is danger.

What is the physical form of SPECTRASYN 100?

SPECTRASYN 100 is a liquid appearing as clear and bright with clear and bright color. It has odourless odor.

What is SPECTRASYN 100 used for?

Base oil

What are the hazard statements for SPECTRASYN 100?

This substance has 3 hazard statements:

  • H310: High-pressure injection under skin may cause serious damage.
  • H313: Low order of toxicity.
  • NOTE: This material should not be used for any other purpose than the intended use in Section 1 without expert advice. Health studies have shown that chemical exposure may cause potential human health risks which may vary from person to person.