NextSDS Logo
Safety Data Sheet EN

Levasil CT17 M

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Levasil CT17 M

Regulatory Identifiers

CAS Number
N/A
UFI Code
G9V4-503P-Q006-524H

Identified Uses

Inorganic binder and surface modifier.

Manufacturers & Suppliers

N

Nouryon Pulp and Performance Chemicals AB

manufacturer

SE 445 80 Bohus, Sweden

+4631587000

Emergency Contacts

Worldwide use

+31 570 679 211

Myrkytystietokeskus

09 471 977

Kemiakuten

020 99 60 00

ORFILA / INRS

0145 42 59 59

NRCC

+86 532 838 890 90

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.

Precautionary Statements

P261 Avoid breathing mist, vapours or spray.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves.
P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/container in accordance with local regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Amorphous Silica, aqueous colloidal solution.

Chemical Name CAS Number Concentration Hazardous
2-Methyl-2H-isothiazole-3-one EC: 220-239-6 2682-20-4 0.0025 - 0.025% Yes

For the full text of the H-Statements mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. Consult a physician after significant exposure.

Skin contact

Take off contaminated clothing and shoes immediately. Wash the skin immediately with soap and water. If skin irritation persists, call a physician.

Eye contact

Rinse with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person. Obtain medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Only qualified personnel equipped with suitable protective equipment may intervene. Prevent unauthorised persons entering the zone.

Large spill

If liquid has been spilt in large quantities clean up promptly by scoop or vacuum.

Environmental

Do not flush into surface water or sanitary sewer system.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal. If liquid has been spilt in large quantities clean up promptly by scoop or vacuum.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid formation of aerosol. Do not breathe vapours or spray mist. Avoid contact with skin. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.

Storage

Keep container tightly closed in a dry and well-ventilated place. Keep away from direct sunlight.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Effective exhaust ventilation system

Hands

Material: PVC, Material: Rubber gloves

Eyes

Tightly fitting safety goggles

Respiratory

No personal respiratory protective equipment normally required. In the case of vapour or aerosol formation use a respirator with an approved filter.

Skin/Body

Protective suit

Environmental

Do not flush into surface water or sanitary sewer system.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
---
Colour Intensity
---
Evaporation Rate
No data available
Vapor Density
---
Appearance
---
Relative Evaporation Rate
---
Metal Corrosion
---
Flash Point
Not applicable
Voc Content
---
Boiling Point
100 °C
Solubility
---
Colour
opalescent
Flammability
The product is not flammable.
Decomposition Temperature
No data available
Solubility In Water
100 - 500 mg/l dispersible
Softening Point
---
Auto Ignition Temperature
Not applicable
Ph
9,2 - 9,7
Explosive Limits
---
Dynamic Viscosity
< 15 mPa.s
Physical State Data
liquid
Vapor Pressure
ca. 23 hPa (20 °C)
Molecular Weight
---
Upper Explosive Limit
Not applicable
Bulk Density
---
Freezing Point
---
Lower Explosive Limit
Not applicable
Solidification Point
---
Properties Status
---
State Under Standard Conditions
---
Relative Density
1,300
Partition Coefficient
No data available
Odor Threshold
No data available
Odor
odourless
Physical State
liquid
Cloud Point
---
Form
---
Melting Point
0 °C
Crystallisation Point
---
Solubility In Fat
---
Kinematic Viscosity
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Avoid drying out of the solution as this can lead to a build up of dust.

Incompatible

Copper, Mild steel, Aluminium

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Do not dispose of waste into sewer. Do not contaminate ponds, waterways or ditches with chemical or used container.

Disposal

Dispose of contents/container in accordance with local regulation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Levasil CT17 M?

The signal word is warning.

What is the physical form of Levasil CT17 M?

Levasil CT17 M is a liquid with opalescent color. It has odourless odor.

What is Levasil CT17 M used for?

Inorganic binder and surface modifier.

What are the hazard statements for Levasil CT17 M?

This substance has 1 hazard statement:

  • H317: May cause an allergic skin reaction.

What is the melting point of Levasil CT17 M?

The melting point is 0 °C and the boiling point is 100 °C.