Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Alcomer® 7523D
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Performance Chemicals for Oilfield Applications
Manufacturers & Suppliers
BASF SE
67056 Ludwigshafen GERMANY
+49 621 60-0
Emergency Contacts
Emergency Contact
+49 180 2273-112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Aqueous solution based on: Polymer, cationic, inorganic salts
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Aluminum chloride, basic EC: 215-477-2 | 1327-41-9 | 15 - 20% | Yes |
| 2-Propen-1-aminium, N,N-dimethyl-N-2-propenyl-, chloride, homopolymer | 26062-79-3 | 1 - 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Keep patient calm, remove to fresh air, seek medical attention. Immediately administer a corticosteroid from a controlled/metered dose inhaler.
Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist.
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist.
Immediately rinse mouth and then drink 200 - 300 ml water, do not induce vomiting, seek medical attention.
Medical Treatment
Treat according to symptoms (decontamination, vital functions), no known specific antidote.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water spray, dry powder, foam
harmful vapours, chlorine compounds Evolution of fumes/fog. The substances/groups of substances mentioned can be released in case of fire.
If without risk, remove intact containers from exposure to fire, or spray unopened containers with water mist to keep cool.
Firefighter Protection
Wear self-contained breathing apparatus and chemical-protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective clothing. Keep unprotected persons away.
Pick up with suitable absorbent material.
Pump off product.
Contain contaminated water/firefighting water. Do not discharge into drains/surface waters/groundwater.
For large amounts: Pump off product. For residues: Pick up with suitable absorbent material.
Materials: suitable absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes. Use suitable eye protection. Wash hands before breaks and at end of work. Remove contaminated clothing and protective equipment before entering eating areas. When using do not eat, drink or smoke.
Keep container tightly closed and in a cool place. Stir before use.
Wash hands before breaks and at end of work. Remove contaminated clothing and protective equipment before entering eating areas. When using do not eat, drink or smoke.
No special precautions necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Chemical resistant protective gloves (EN ISO 374-1) Suitable materials also with prolonged, direct contact (Recommended: Protective index 6, corresponding > 480 minutes of permeation time according to EN ISO 374-1): e.g. nitrile rubber (0.4 mm), chloroprene rubber (0.5 mm), polyvinylchloride (0.7 mm) and other Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing. Manufacturer's directions for use should be observed because of great diversity of types.
Tightly fitting safety goggles (splash goggles) (e.g. EN 166)
Suitable respiratory protection for higher concentrations or long-term effect: Gas filter for gases/vapours of organic compounds (boiling point >65 °C, e. g. EN 14387 Type A)
chemical-protection suit (f.e. according to EN 14605)
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable if stored and handled as prescribed/indicated.
No hazardous reactions if stored and handled as prescribed/indicated. Corrosion to metals: Corrosive effect on metals.
No hazardous reactions when stored and handled according to instructions.
No conditions to avoid anticipated.
oxidizing agents, acids
No hazardous decomposition products if stored and handled as prescribed/indicated.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3264
- Shipping Name
- CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (ALUMINIUM CHLORIDE, BASIC)
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Alcomer® 7523D?
The signal word is danger.
What is the physical form of Alcomer® 7523D?
Alcomer® 7523D is a liquid with colourless to yellow color. It has odourless odor.
What is Alcomer® 7523D used for?
Performance Chemicals for Oilfield Applications
What are the hazard statements for Alcomer® 7523D?
This substance has 2 hazard statements:
- H290: May be corrosive to metals.
- H318: Causes serious eye damage.
What is the melting point of Alcomer® 7523D?
The melting point is < 0 °C and the boiling point is 100 - 120 °C.