NextSDS Logo
Safety Data Sheet EN

NX 795

EC 246-771-9

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NX 795

Regulatory Identifiers

CAS Number
N/A
EC Number
246-771-9 Check regulations →
REACH No.
01-2119441305-48-0002

Identified Uses

Industrial use, Raw material, Intermediate, Additive, Carrier, Adhesives, Water-borne coatings, Lubricants and lubricant additives, Drilling applications, Flocculating agent Intermediate

Manufacturers & Suppliers

S

Synthomer Speciality Additives AB.

Durmakker 33 9940 Evergem

+3292571717

Emergency Contacts

Emergency Contact

+44 (0) 1235 239 670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
N/A --- --- No

Notes

No dangerous ingredients according to Regulation (EC) No. 1907/2006

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air.

Skin contact

Wash off with plenty of water.

Eye contact

Rinse thoroughly with plenty of water, also under the eyelids.

Ingestion

Get medical attention if symptoms occur. If large quantities of this material are swallowed, call a physician immediately.

Immediate Medical Attention

Get medical attention if symptoms occur. If large quantities of this material are swallowed, call a physician immediately.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product is compatible with standard fire-fighting agents. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

May release toxic, irritating and/or corrosive gases.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Contain spillage, soak up with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and transfer to a container for disposal according to local / national regulations (see section 13).

Large spill

Large spills should be collected mechanically (remove by pumping) for disposal. Pick up and transfer to properly labelled containers.

Environmental

The product should not be allowed to enter drains, water courses or the soil.

Cleanup methods

transfer to a container for disposal according to local / national regulations (see section 13). Pick up and transfer to properly labelled containers. After cleaning, flush away traces with water.

Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle in accordance with good industrial hygiene and safety practice.

Storage

Keep tightly closed.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special precautions required.

Hands

Material : Nitrile rubber Material : Chloroprene Material : butyl-rubber Remarks : Protective gloves complying with EN 374.

Eyes

Safety goggles

Respiratory

not required under normal use

Skin/Body

Long sleeved clothing

Environmental

General advice: The product should not be allowed to enter drains, water courses or the soil.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
---
Density
---
Properties Status
---
Crystallisation Point
---
Colour
colourless
Appearance
liquid
Relative Evaporation Rate
---
Freezing Point
-70.25 °C
Relative Density
0.95
Metal Corrosion
---
Solubility
---
Voc Content
---
Partition Coefficient
log Pow: 3.2 (25 °C)
Evaporation Rate
No data available
Auto Ignition Temperature
380 °C
Molecular Weight
---
Odor
slight
Vapor Density
---
Flash Point
114 °C
Flammability
---
State Under Standard Conditions
---
Boiling Point
257 °C
Vapor Pressure
0.013 hPa (20 °C)
Softening Point
---
Bulk Density
No data available
Lower Explosive Limit
Not applicable
Decomposition Temperature
---
Solidification Point
---
Physical State Data
liquid
Physical State
liquid
Odor Threshold
No data available
Upper Explosive Limit
Not applicable
Colour Intensity
---
Explosive Limits
---
Solubility In Fat
---
Melting Point
-70.25 °C
Solubility In Water
< 1 g/l (20 °C)
Form
---
Kinematic Viscosity
---
Ph
3.54 (20 °C)
Cloud Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

None known.

Avoid

Heat

Incompatible

Strong oxidizing agents

Decomposition

Carbon dioxide (CO2) Carbon monoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NX 795?

The signal word is no signal word.

What is the physical form of NX 795?

NX 795 is a liquid appearing as liquid with colourless color. It has slight odor.

What is NX 795 used for?

Industrial use, Raw material, Intermediate, Additive, Carrier, Adhesives, Water-borne coatings, Lubricants and lubricant additives, Drilling applications, Flocculating agent Intermediate

What is the melting point of NX 795?

The melting point is -70.25 °C and the boiling point is 257 °C.

Compliance Scanner

Scan your compliance