Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- NACOL 12 - 99
- Chemical Name
- dodecan-1-ol
- Synonyms
- Lauryl Alcohol
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- 01-2119485976-15-0000
Identified Uses
Industrial use raw material for cosmetic agents raw material for washing and cleaning agents raw material for textile auxiliary agents raw material for synthesis processes in the chemical industry emulsifying agent raw material for lubricants and lubricant additives raw material for fragrances raw material for stabilizers
Manufacturers & Suppliers
SASOL Germany GmbH
manufacturer
Anckelmannsplatz 1 20537 Hamburg
+49 40 63684-1000
Emergency Contacts
GIZ-Nord Poisons Centre
+49 (0) 5 51 - 1 92 40
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS09
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Dodecan-1-ol EC: 203-982-0 | 112-53-8 | --- | Yes |
Notes
For the full text of the H-Statements mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from exposure, lie down. If breathing is irregular or stopped, administer artificial respiration. Monitor breathing, give oxygen if necessary. Consult a physician.
Wash off with plenty of water.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Consult a physician. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person.
Medical Treatment
No information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, Dry powder, Foam, Carbon dioxide (CO2)
Dangerous gases or fumes may occur in case of fire.
Firefighter Protection
Use personal protective equipment. Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In the event of transport accidents, request support from the nearest TUIS centre.
Avoid subsoil penetration. Do not flush into surface water or sanitary sewer system.
Soak up with inert absorbent material
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment.
No special storage conditions required. Protect from frost, heat and sunlight.
No special protective measures against fire required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide sufficient air exchange and/or exhaust in work rooms.
The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other., Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time., Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside influences (e.g. temperature). gloves suitable for permanent contact: Material: Nitrile rubber/nitrile latex, Break through time: >= 480 min, Layer thickness: 0.35 mm Material: butyl-rubber, Break through time: >= 480 min, Layer thickness: 0.5 mm unsuitable gloves Material: Natural rubber/natural latex
Tightly fitting safety goggles
No personal respiratory protective equipment normally required. In inadequately ventilated areas, where workplace limits are exceeded, where unpleasant odours exist or where aerosols are in use, or smoke and mist occur, use self-contained breathing apparatus or breathing apparatus with a type A filter or appropriate combined filter (e.g. where aerosols are in use, or smoke and mist occur, A-P2 or ABEK-P2), in compliance with EN 141.
Protective suit
Avoid subsoil penetration. Do not flush into surface water or sanitary sewer system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if stored and applied as directed.
Stable at normal ambient temperature and pressure.
Hazardous decomposition products formed under fire conditions.
Direct heating, dirt, chemical contamination, sunlight, UV or ionising radiation.
No data available;
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3077
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (1-Dodecanol)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is NACOL 12 - 99 known by?
NACOL 12 - 99 is also known as: Lauryl Alcohol
What is the hazard signal word for NACOL 12 - 99?
The signal word is warning.
What is the physical form of NACOL 12 - 99?
NACOL 12 - 99 is a solid; 20 °c; 1,013 hpa with colourless color. It has characteristic odor.
What is NACOL 12 - 99 used for?
Industrial use raw material for cosmetic agents raw material for washing and cleaning agents raw material for textile auxiliary agents raw material for synthesis processes in the chemical industry emulsifying agent raw material for lubricants and lubricant additives raw material for fragrances raw material for stabilizers
What are the hazard statements for NACOL 12 - 99?
This substance has 3 hazard statements:
- H319: Causes serious eye irritation.
- H400: Very toxic to aquatic life.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of NACOL 12 - 99?
The melting point is ca. 22 - 25 °C and the boiling point is ca. 255 - 265 °C.