Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MOTIP CAR CARE DE-ICER DOORLOCK 75 ML
- Product Code
- 000790ER
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Auxiliary
Manufacturers & Suppliers
European Aerosols B.V.
manufacturer
Wolframweg 2, NL-8471 XC Wolvega, The Netherlands
+31 (0)561 694400
European Aerosols Ltd.
distributor
Wilberforce House, Station Road, London NW4 4QE
+44 1223 790332
Emergency Contacts
Emergency Contact
+31 (0)561-694400
09:00h - 17:00h
NPIS National Poisons Information Centre
+44 0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| propan-2-ol EC: 200-661-7 | 67-63-0 | 50 - 75% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 5 - 10% | Yes |
| ethanediol EC: 203-473-3 | 107-21-1 | 5 - 10% | Yes |
| butane (containing < 0,1 % butadiene (203-450-8)) EC: 203-448-7 | 106-97-8 | 5 - 10% | Yes |
| isobutane (containing < 0,1 % butadiene (203-450-8)) EC: 200-857-2 | 75-28-5 | 5 - 10% | Yes |
In accordance with the current Annex II of UK REACH, the concentration of the substances contained in the mixture are specified. For the classification of aerosols, the values used for calculation may differ. For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Drink plenty of water and provide fresh air. Call for a doctor immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions.
During heating or in case of fire poisonous gases are produced.
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Keep respiratory protective device available.
Keep container tightly sealed.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Protective gloves. Material of gloves: Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: Butyl rubber gloves with a thickness of 0.4 mm are resistant to: Acetone: 480 min, Butyl acetate: 60 min, Ethyl acetate: 170 min, Xylene: 42 min. Butyl rubber gloves with a thickness of 0.4 mm are solvent resistant for 42-480 minutes. As protective measure, we recommend that users and responsible persons for work safety assume solvent resistance length of 42 minutes. Considering the data in section 3 of this SDS, one can assume longer resistance length in particular cases.
Tightly sealed goggles
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Filter A2/P3
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
No further relevant information available.
12.3 Bioaccumulative potential
No further relevant information available.
12.4 Mobility in soil
No further relevant information available.
12.5 Results of PBT and vPvB assessment
The substance is not considered PBT or vPvB.
12.6 Endocrine disrupting properties
The product does not contain substances with endocrine disrupting properties.
12.7 Other adverse effects
Water hazard class 1 (German Regulation) (Self-assessment): slightly hazardous for water. Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Must not be disposed together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- not regulated
Warning: Gases. - F-D,S-U SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow "separated from" class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
None of the ingredients is listed in the Poisons Act (regulated/reportable explosives precursors and poisons).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MOTIP CAR CARE DE-ICER DOORLOCK 75 ML?
The signal word is danger.
What is the physical form of MOTIP CAR CARE DE-ICER DOORLOCK 75 ML?
MOTIP CAR CARE DE-ICER DOORLOCK 75 ML is a aerosol with colourless color. It has alcohol-like odor.
What is MOTIP CAR CARE DE-ICER DOORLOCK 75 ML used for?
Auxiliary
What are the hazard statements for MOTIP CAR CARE DE-ICER DOORLOCK 75 ML?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of MOTIP CAR CARE DE-ICER DOORLOCK 75 ML?
The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..