Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dashboard Wipes
- Product Code
- 83223
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
FOR PROFESSIONAL AND INDUSTRIAL USE ONLY, Surface cleanser
Manufacturers & Suppliers
KENT (United Kingdom) Ltd
manufacturer
Forsyth House, Pitreavie Drive, Pitreavie Business Park, Dunfermline, Fife, KY11 8US
0800 136925
Emergency Contacts
KENT (United Kingdom) Ltd
+44 01383 723344
During normal office hours - Monday - Thursday 8.30am - 5.30pm, Friday 9.00am - 3.00pm
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of the substances listed below with harmless additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propan-2-ol EC: 200-661-7 | 67-63-0 | 5 - 10% | Yes |
| preservation agents | --- | 15 - 30% | No |
| ISOPROPYL ALCOHOL | --- | 5 - 15% | No |
| Perfumes | --- | 5% | No |
| Cationic surfactants | --- | 5% | No |
| METHYLISOTHIAZOLINONE | --- | 5% | No |
| BENZISOTHIAZOLINONE | --- | 5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of symptoms.
Instantly wash with water and soap and rinse thoroughly. Generally the product is not skin irritating.
Rinse opened eye for several minutes under running water. Then consult doctor.
In case of persistent symptoms consult doctor.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire fighting measures that suit the environment.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not required.
Do not allow to enter drainage system, surface or ground water. Dilute with much water.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures required.
Store in cool, dry conditions in well sealed containers.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: Value for the permeation: Level 6 > 480 minutes. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses (EN 166)
Not necessary if room is well-ventilated.
Protective work clothing (EN-13034/6)
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dashboard Wipes?
The signal word is no signal word.
What is the physical form of Dashboard Wipes?
Dashboard Wipes is a fluid with colourless color. It has mild odor.
What is Dashboard Wipes used for?
FOR PROFESSIONAL AND INDUSTRIAL USE ONLY, Surface cleanser
What is the melting point of Dashboard Wipes?
The melting point is Not determined and the boiling point is Not determined.