NextSDS Logo
Safety Data Sheet EN

Heat-Transfer Fluid

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Heat-Transfer Fluid
Product Code
3DA811

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Heat-Transfer Fluid is an effective heat transfer media that transfers energy from the test sample to the cooling system within the osmometer and cryoscope instruments. Used in a closed loop, the liquid flows from the reservoir to the cooling well, then returns to the reservoir.

Manufacturers & Suppliers

A

Advanced Instruments

manufacturer

2 Technology Way, USA-Norwood, MA 02062, USA

+1 (781) 320-9000

Emergency Contacts

Rocky Mountain Poison & Drug Center

+1 (877) 740-5015

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Methyl glycol 57-55-6 37.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire fighting measures that suit the environment.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Goggles recommended during refilling.

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
According to product specification
Colour
According to product specification
Colour Intensity
---
Form
Fluid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
185 °C (365 °F)
Flash Point
101 °C (213.8 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
23 hPa (17.3 mm Hg)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
12.6 Vol%
Lower Explosive Limit
2.6 Vol%
Explosive Limits
---
Auto Ignition Temperature
371 °C (699.8 °F)
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
37.5 %; 375.0 g/l / 3.13 lb/gl
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Heat-Transfer Fluid?

The signal word is no signal word.

What is the physical form of Heat-Transfer Fluid?

Heat-Transfer Fluid is a fluid appearing as according to product specification with according to product specification color. It has characteristic odor.

What is Heat-Transfer Fluid used for?

Heat-Transfer Fluid is an effective heat transfer media that transfers energy from the test sample to the cooling system within the osmometer and cryoscope instruments. Used in a closed loop, the liquid flows from the reservoir to the cooling well, then returns to the reservoir.

What is the melting point of Heat-Transfer Fluid?

The melting point is Undetermined. and the boiling point is 185 °C (365 °F).