Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU
- Product Code
- 246149
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- J21E-YEEG-700R-K04X
Identified Uses
Water analysis
Manufacturers & Suppliers
HACH LANGE GmbH
manufacturer
Willstätterstr. 11, D-40549 Düsseldorf
+49 (0)211 5288-383
www.de.hach.com
HACH LANGE Ltd.
distributor
5, Pacific Way, Salford Manchester M50 1DL - United Kingdom
+44 (0) 161 872 1487
HACH LANGE Ltd.
distributor
Unit 1, Chestnut Road Western Industrial Estate, IRL-Dublin 12
+353 (0)1 4602522
Emergency Contacts
Poison Control Center Mainz
+49 (0) 6131 19240
24 hour emergency service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Water EC: 231-791-2 | 7732-18-5 | 90% | No |
| methenamine; hexamethylenetetramine EC: 202-905-8 | 100-97-0 | 1 - 5% | Yes |
| Formazine polymer | 1263063-17-7 | 0.5% | No |
| formaldehyde ... % EC: 200-001-8 | 50-00-0 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, call a physician.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Do NOT induce vomiting. Clean mouth with water and drink afterwards plenty of water. Consult a physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. The product itself does not burn.
None known.
Fire may liberate hazardous vapours. Ammonia, Carbon monoxide, Formaldehyde, Nitrogen dioxide.
In the event of fire, wear self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not flush into surface water or sanitary sewer system.
Soak up with inert absorbent material and dispose of as hazardous waste.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
26599-49 StabilCal Formazin Turbidity Standard, 10 NTU
UFI: V55R-AYJ6-7110-9RAP
26606-49 StabilCal Stabilized Formazin Primary Standard; 1000 NTU
UFI: 98W2-40MF-M215-V9A0
521 Nitrosamines Calibration Standard
---
GPC Calibration Standard Solution
---
Safranine O (C.I. 50240) for microscopy Certistain®
---
Custom Semivolatile Mix, 3-2200, 25,000 mg/L
---
D-2887 Calibration Mix
---
LCK 341 Nitrit/Nitrite, Sample cuvette; 1/2
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas. Do not breathe vapours/dust. Avoid contact with skin and eyes. General industrial hygiene practice. Avoid contact with skin, eyes and clothing.
Keep tightly closed in a dry, cool and well-ventilated place. Storage temperature: 5-25 °C. Protect against light.
General industrial hygiene practice.
None known.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.
Use barrier skin cream. Chemical resistant gloves made of butyl rubber or nitrile rubber category III according to EN 374. In full contact: Gloves material: Viton, Layer thickness: 0.70 mm, Breakthrough time: >480 min. In splash contact: Glove material: nitrile rubber, Layer thickness 0,20 mm, Breakthrough time: > 30 min. Consult your supplier if the material is to be used for special applications such as in the food industry or for hygiene, medical or surgical end-use.
Safety glasses with side-shields
Ensure adequate ventilation, especially in confined areas. In case of insufficient ventilation, wear suitable respiratory equipment. In the case of vapour formation use a respirator with an approved filter. Respirator with a gas filter (gas filter type A or B or K)
Avoid contact with skin and clothing. Remove and wash contaminated clothing before re-use.
Do not flush into surface water or sanitary sewer system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
None known.
Oxidizing agents
Keep away from heat.
No dangerous reaction known under conditions of normal use.
To avoid thermal decomposition, do not overheat. Decomposition products: Ammonia, Carbon monoxide, Formaldehyde, Nitrogen dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU?
The signal word is danger.
What is the physical form of 2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU?
2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU is a suspension with off-white color. It has odourless odor.
What is 2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU used for?
Water analysis
What are the hazard statements for 2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
What is the melting point of 2461-49 StabilCal Formazin Turbidity Standard, 4000 NTU?
The melting point is not applicable and the boiling point is 100 °C.