Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HARDENER FOR EPOXY PRIMER
- Product Code
- P275-3022/E2.5
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Professional applications, Used by spraying.
Manufacturers & Suppliers
PPG Industries (UK) Ltd.
national supplier
Needham Road, Stowmarket, Suffolk, IP14 2AD, UK
Nexa Autocolor, Customer Service and Sales Group
national supplier
Needham Road, Stowmarket, Suffolk, IP14 2AD, UK
+44 (0) 1449 771771
Emergency Contacts
PPG Industries (UK) Ltd.
+44 (0) 1449 773 338
0900-1600
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.
Symptoms: Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness. May cause respiratory irritation. Adverse symptoms may include the following: respiratory tract irritation, coughing, nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness.
Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser. Do NOT use solvents or thinners.
Symptoms: Causes skin irritation. Defatting to the skin. Adverse symptoms may include the following: pain or irritation, redness, dryness, cracking, blistering may occur.
Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open. Seek immediate medical attention.
Symptoms: Causes serious eye damage. Adverse symptoms may include the following: pain, watering, redness.
If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.
Symptoms: Can cause central nervous system (CNS) depression. Adverse symptoms may include the following: stomach pains.
Immediate Medical Attention
Seek immediate medical attention (for eye contact). Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
Flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapour or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapour or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use non-sparking tools. Take precautionary measures against electrostatic discharges. To avoid fire or explosion, dissipate static electricity during transfer by earthing and bonding containers and equipment before transferring material. Empty containers retain product residue and can be hazardous. Do not reuse container.
Storage temperature: 0 to 35°C (32 to 95°F). Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials and food and drink. Store locked up. Eliminate all ignition sources. Separate from oxidizing materials. Keep container tightly closed and sealed until ready for use.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source. Use non-sparking tools. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. For prolonged or repeated handling, use the following type of gloves: Recommended: polyvinyl alcohol (PVA), Viton®, butyl rubber, neoprene May be used: nitrile rubber
Chemical splash goggles and face shield. Use eye protection according to EN 166.
Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Wear a respirator conforming to EN140. Filter type: organic vapour (Type A) and particulate filter P3
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
When exposed to high temperatures may produce hazardous decomposition products. Refer to protective measures listed in sections 7 and 8.
Keep away from the following materials to prevent strong exothermic reactions: oxidising agents, strong alkalis, strong acids.
Depending on conditions, decomposition products may include the following materials: carbon oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HARDENER FOR EPOXY PRIMER?
The signal word is danger.
What is the physical form of HARDENER FOR EPOXY PRIMER?
HARDENER FOR EPOXY PRIMER is a liquid. appearing as colourless. with colourless. color. It has characteristic. odor.
What is the solubility of HARDENER FOR EPOXY PRIMER?
Insoluble in the following materials: cold water.
What is HARDENER FOR EPOXY PRIMER used for?
Professional applications, Used by spraying.
What are the hazard statements for HARDENER FOR EPOXY PRIMER?
This substance has 6 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H372: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of HARDENER FOR EPOXY PRIMER?
The melting point is May start to solidify at the following temperature: -94.9°C (-138.8°F) This is based on data for the following ingredient: ethylbenzene. Weighted average: -96.87°C (-142.4°F) and the boiling point is >37.78°C.