NextSDS Logo
Safety Data Sheet EN

3M™ Adhesive Remover 6040/6041 (Aerosol)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
3M™ Adhesive Remover 6040/6041 (Aerosol)
Product Form
Aerosol
Product Code
62-4667-2925-8, 62-4667-2928-2, 62-4667-2930-8, 62-4667-2935-7, 62-4667-4930-6, 62-4667-4932-2, 62-4667-4935-5, 7000121409, 7000121410, 7000121411

Regulatory Identifiers

CAS Number
N/A

Identified Uses

adhesive remover

Uses advised against

This chemical/product is not and cannot be distributed in commerce (as defined in TSCA section 3(5)) or processed (as defined in TSCA section 3(13)) for consumer paint or coating removal.

Manufacturers & Suppliers

3

3M

manufacturer

3M Center, St. Paul, MN 55144-1000, USA

1-888-3M HELPS (1-888-364-3577)

Emergency Contacts

Emergency Contact

1-800-364-3577

24 hours

Emergency Contact

(651) 737-6501

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1
Press. Gas (Liq.)
Skin Irrit. Cat. 2
Skin Sens. Cat. 1B
Carc. Cat. 1B
STOT SE Cat. 1

GHS Pictograms

GHS02 - Flammable

GHS02

GHS04 - Compressed gas

GHS04

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H222 Extremely flammable aerosol.
H280 Contains gas under pressure; may explode if heated.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H350 May cause cancer.
H370 Causes damage to organs: cardiovascular system

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Pressurized container: Do not pierce or burn, even after use.
P260 Do not breathe dust/fume/gas/mist/vapors/spray.
P264 Wash thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P272 Contaminated work clothing must not be allowed out of the workplace.
P280 Wear protective gloves and eye/face protection.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical advice/attention.
P321 Specific treatment (see Notes to Physician on this label).
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P337 + P313 If eye irritation persists: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P403 Store in a well-ventilated place.
P405 Store locked up.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50°C/122°F.
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Citrus extract 5989-27-5 80 - 90% No
Propane 74-98-6 10 - 19% No
MYRCENE 123-35-3 3% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air. Get medical attention.

Skin contact

Immediately wash with soap and water. Remove contaminated clothing and wash before reuse. If signs/symptoms develop, get medical attention.

Symptoms: Allergic skin reaction (redness, swelling, blistering, and itching).

Eye contact

Flush eyes with large amounts of water. If signs/symptoms persist, get medical attention.

Ingestion

Rinse mouth. If you feel unwell, get medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Exposure may increase myocardial irritability.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use a fire fighting agent suitable for the surrounding fire.

Specific hazards

Closed containers exposed to heat from fire may build pressure and explode.

Instructions

Water may not effectively extinguish fire; however, it should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate area. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.

Large spill

For larger spills, cover drains and build dikes to prevent entry into sewer systems or bodies of water. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors.

Environmental

For larger spills, cover drains and build dikes to prevent entry into sewer systems or bodies of water.

Cleanup methods

Collect as much of the spilled material as possible using non-sparking tools. Place in a metal container approved for transportation by appropriate authorities. Clean up residue with an appropriate solvent selected by a qualified and authorized person. Ventilate the area with fresh air.

Materials: bentonite, vermiculite, or commercially available inorganic absorbent material; appropriate solvent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep out of reach of children. Do not handle until all safety precautions have been read and understood. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use. Do not breathe dust/fume/gas/mist/vapors/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reuse. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.) Use personal protective equipment (gloves, respirators, etc.) as required.

Storage

Store in a well-ventilated place. Protect from sunlight. Do not expose to temperatures exceeding 50°C/122°F. Store away from heat. Store away from acids. Store away from oxidizing agents.

Hygiene

Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reuse.

Fire prevention

Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment. Use explosion-proof ventilation equipment.

Hands

Select and use gloves approved to relevant local standards to prevent skin contact based on the results of an exposure assessment. Consult with your glove manufacturer for selection of appropriate compatible gloves. Note: Nitrile gloves may be worn over polymer laminate gloves to improve dexterity. Gloves made from the following material(s) are recommended: Polymer laminate

Eyes

Full Face Shield, Indirect Vented Goggles

Respiratory

An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates, Half facepiece or full facepiece supplied-air respirator

Skin/Body

Select and use protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment. If this product is used in a manner that presents a higher potential for exposure (eg. spraying, high splash potential etc.), then use of protective coveralls may be necessary. The following protective clothing material(s) are recommended: Apron - polymer laminate

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
9.5 % volume [Details:CONDITIONS: PROPANE]
Odor Threshold
No Data Available
Density
0.793 g/ml
Flash Point
-50.00 °F
Physical State Data
aerosol
Decomposition Temperature
No Data Available
Colour Intensity
---
Partition Coefficient
No Data Available
State Under Standard Conditions
---
Cloud Point
---
Ph
Not Applicable
Vapor Pressure
55 psi [@ 20 °C] [Details:Composite Vapor Pressure (Calculated)]
Lower Explosive Limit
2.1 % volume [Details:CONDITIONS: PROPANE]
Solubility
---
Boiling Point
Not Applicable
Dynamic Viscosity
---
Solidification Point
---
Solubility In Fat
---
Flammability
Not Applicable
Molecular Weight
---
Colour
Light Yellow
Metal Corrosion
---
Kinematic Viscosity
---
Evaporation Rate
No Data Available
Explosive Limits
---
Crystallisation Point
---
Solubility In Water
---
Form
Aerosol
Freezing Point
---
Appearance
Light Yellow
Bulk Density
---
Relative Evaporation Rate
---
Vapor Density
Not Applicable
Properties Status
---
Softening Point
---
Melting Point
No Data Available
Odor
Sweet Odor
Physical State
Liquid aerosol
Auto Ignition Temperature
No Data Available
Voc Content
100 % [Test Method:calculated per CARB title 2]
Relative Density
0.793 [Ref Std:WATER=1]
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Reactivity

This material may be reactive with certain agents under certain conditions - see the remaining headings in this section.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Heat

Incompatible

Strong oxidizing agents

Decomposition

None known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 3M™ Adhesive Remover 6040/6041 (Aerosol)?

The signal word is danger.

What is the physical form of 3M™ Adhesive Remover 6040/6041 (Aerosol)?

3M™ Adhesive Remover 6040/6041 (Aerosol) is a liquid aerosol appearing as light yellow with light yellow color. It has sweet odor odor.

What is 3M™ Adhesive Remover 6040/6041 (Aerosol) used for?

adhesive remover

What are the hazard statements for 3M™ Adhesive Remover 6040/6041 (Aerosol)?

This substance has 6 hazard statements:

  • H222: Extremely flammable aerosol.
  • H280: Contains gas under pressure; may explode if heated.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H350: May cause cancer.
  • H370: Causes damage to organs: cardiovascular system

What is the melting point of 3M™ Adhesive Remover 6040/6041 (Aerosol)?

The melting point is No Data Available and the boiling point is Not Applicable.