Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- X1 eXcellent Heavy Duty cleaner - degreaser
- Product Form
- Aerosol
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- G6N0-20RA-D00P-9H10
Identified Uses
Consumer use, Industrial use, Professional use
Uses advised against
None identified.
Manufacturers & Suppliers
RUST-OLEUM EUROPE (Martin Mathys NV)
manufacturer
Kolenbergstraat 23, B-3545 Zelem, Belgium
+32 (0) 13 460 200
Tor Coatings Limited
distributor
Unit 21, White Rose Way, Follingsby Park, Gateshead, Tyne & Wear, NE10 8YX United Kingdom
+44 (0) 191 4106611
Emergency Contacts
Poison centre
+32(0)70 245 245
Emergency Contact
+359 2 9154 409
Emergency Contact
+385 1 2348 342
Emergency Contact
1401
Toxikologické informační středisko
+420 224 919 293
Toxikologické informační středisko
+420 224 915 402
Giftlinien
82 12 12 12
Emergency Contact
16662
Emergency Contact
0800 147 111
ORFILA (INRS)
+33 (0)1 45 42 59 59
Emergency Telephone Poison Center Nos. Children Aglaia Kyriakou
+30 210 7793777
Health Toxicology Information Service (ETTSZ)
(+ 36-80) 201-199
Emergency Contact
+354 5432222
Emergency Contact
809 2166
Emergency Contact
800183459
Toxicology and sepsis clinics Poisoning and Drug Information Center
+371 67042473
Poison Information Office
+370 (5) 2362052
Poison centre
+32(0)70 245 245
Emergency Contact
112
Emergency Contact
088-755 8000
Emergency Contact
+47 22 59 13 00
Emergency Contact
112
Emergency Contact
800 250 250
Emergency Contact
+40 21 318 36 06
NATIONAL TOXICOLOGICAL INFORMATION CENTER
+421 2 5477 4166
Emergency Contact
915 620 420
Poison Information Center
112
Swiss Toxicological Information Centre
145
Emergency Contact
809 2166
Emergency Contact
+43 13649237
Emergency Contact
+32 28083237
Emergency Contact
+359 32570104
Emergency Contact
+385 17776920
Emergency Contact
+420 228880039
Emergency Contact
+45 69918573
Emergency Contact
+372 6681294
Emergency Contact
+358 942419014
Emergency Contact
+33 975181407
Emergency Contact
+49 69643508409
Emergency Contact
0800-181-7059
Emergency Contact
+30 2111768478
Emergency Contact
+36 18088425
Emergency Contact
+354 539 0655
Emergency Contact
+353 19014670
Emergency Contact
+39 0245557031
Emergency Contact
800-789-767
Emergency Contact
+371 66165504
Emergency Contact
+370 52140238
Emergency Contact
352-20202416
Emergency Contact
+31 858880596
Emergency Contact
+48 223988029
Emergency Contact
+351 308801773
Emergency Contact
+40 37 6300026
Emergency Contact
+421 233057972
Emergency Contact
+38 618888016
Emergency Contact
+34 931768545
Emergency Contact
+46 852503403
Emergency Contact
+41 435082011
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrocarbons, C11-C14, n-/iso-/ cyclo-alkanes, < 2% aromatics EC: 926-141-6 | 64742-47-8 | 50 - 75% | Yes |
| alcohols, C9-11, ethoxylated EC: 614-482-0 | 68439-46-3 | 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: respiratory tract irritation, coughing
Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: irritation, dryness, cracking
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Symptoms: pain or irritation, watering, redness
Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Immediate Medical Attention
Get medical attention if adverse health effects persist or are severe. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, alcohol-resistant foam or water spray (fog).
Do not use water jet.
Extremely flammable aerosol. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Avoid breathing vapour or mist. Provide adequate ventilation. Do not touch or walk through spilt material. Shut off all ignition sources.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C. Do not pierce or burn, even after use. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Avoid breathing vapour or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous.
Do not store above the following temperature: 35°C (95°F). Store in accordance with local regulations. Store away from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Eliminate all ignition sources.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source. Eliminate all ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapour or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. > 8 hours (breakthrough time): polyethylene (PE), polyvinyl alcohol (PVA), neoprene (0.65mm). The recommendation for the type or types of glove to use when handling this product is based on information from the following source: EN374. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. Use eye protection according to EN 166. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: organic vapour (Type A) and particulate filter (EN 140).
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Recommended: Personnel should wear antistatic clothing made of natural fibres or of high-temperature-resistant synthetic fibres. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
Avoid all possible sources of ignition (spark or flame).
No specific data.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- AEROSOLS, flammable
- Transport Class
- 2
63, 190, 277, 327, 344, 381, 959
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for X1 eXcellent Heavy Duty cleaner - degreaser?
The signal word is danger.
What is the physical form of X1 eXcellent Heavy Duty cleaner - degreaser?
X1 eXcellent Heavy Duty cleaner - degreaser is a aerosol with colourless. color. It has solvent-like odor.
What is X1 eXcellent Heavy Duty cleaner - degreaser used for?
Consumer use, Industrial use, Professional use
What are the hazard statements for X1 eXcellent Heavy Duty cleaner - degreaser?
This substance has 2 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: may burst if heated.
- H319: Causes serious eye irritation.