Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BSE 32 OIL
- Product Form
- Polyol Ester
- Product Code
- 1186551 Ester
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Synthetic refrigeration compressor oil
Manufacturers & Suppliers
BITZER Australia Pty Ltd
manufacturer
134 - 136 Dunheved Circuit, St Marys NSW 2760
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
BITZER Australia Pty Ltd
(02) 8801 9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Polyol esters
Notes
The components are not hazardous or below required disclosure limits.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure and remove the source of contamination. Move the victim to fresh air and ensure airways are clear. If oil mist is inhaled, remove to fresh air and seek medical attention.
Symptoms: respiratory irritation, nausea, or unconsciousness
Remove any contaminated clothing. Wash exposed skin and contact areas with soap and water gently. If product gets under the skin seek immediate medical attention from a physician.
Symptoms: Prolonged exposure may irritate the skin.
Wash thoroughly with clean water if contact with the eye occurs.
Symptoms: irritation and soreness
Immediately wash out mouth with clean water. Do not induce vomiting.
Immediate Medical Attention
If respiratory irritation, nausea, or unconsciousness occurs, seek immediate medical assistance. If product gets under the skin seek immediate medical attention from a physician. Seek medical attention if irritation and soreness develops or persists in eyes.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, or dry chemical to extinguish flames. Water fog may be used to cool exposed containers.
DO NOT use water jet.
Burning product or fluid may evolve irritating/noxious fumes.
Evacuate area as soon as possible. Water spray may be used to cool fire exposed surfaces and protect personnel.
Firefighter Protection
Firefighters should use protective clothing / equipment and approved self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop source of leak or spill if you can do so without risk.
use inert absorbent material (eg. sand, sawdust or diatomaceous earth) to soak up the spilled product.
dike the spill area for containment and recovery if possible. Place inert absorbent material onto the spillage.
Prevent spill entering drains, waterways, sewers, rivers, basements etc.
Place inert absorbent material onto the spillage.
Materials: inert absorbent material (eg. sand, sawdust or diatomaceous earth)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not take internally. Avoid contact with skin, eyes and clothing. Upon contact with skin, wash with sufficient amounts of water and soap. Flush eyes with water for 15 minutes and seek medical attention. Wash contaminated clothing or dispose appropriately. Repeated or prolonged contact with this material should be avoided in order to reduce the possibility of skin disorders. Misuse of empty containers can be hazardous. Do not cut, weld, heat or drill containers. Residue in the container may ignite if exposed to heat. Do not expose container to open flame or excess heat. Always keep container closed and caps in place.
This product is hydrosopic and storage under dry nitrogen is recommended. Keep container tightly sealed when not in use. Store in a cool, dry, well-ventilated area, out of direct sunlight. Keep away from open flames and other ignition sources.
Observe good personal hygiene.
Keep away from open flames and other ignition sources. Residue in the container may ignite if exposed to heat. Do not expose container to open flame or excess heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well ventilated area. Where vapours or oil mists are generated and exposure standards are exceeded, the use of personal respiratory protection equipment or an adequate exhaust ventilation system is recommended.
Protective gloves is normally not required, but impervious gloves such as nitrile, viton or neoprene is recommended if required. Contact the glove manufacturer for specific advice on glove selection. Inspect and replace worn or damaged gloves.
Goggles or safety glasses with side shields are recommended.
If engineering controls are still inadequate, the use of an approved respirator with organic vapour / particulate filter complying with AS/NZS 1715 (Selection, Use and Maintenance of Respiratory Protective Devises) and AS/NZS 1716 (Respiratory Protective Devices) is recommended. The selection of type of breathing protection should be based on expert advice. Reference should be made to the relevant Australian Standards. In the case of high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode.
No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact. If required, use a chemical resistance apron to avoid contact of material with skin.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and handling
Will not occur
Excessive heat or sources of ignition
oxidizing materials
Material does not decompose at ambient temperatures. Analogous compounds evolve carbon monoxide, carbon dioxide, and other unidentified products and fragments when burned.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BSE 32 OIL?
The signal word is no signal word.
What is the physical form of BSE 32 OIL?
BSE 32 OIL is a liquid with clear to light yellow color. It has mild odor.
What is BSE 32 OIL used for?
Synthetic refrigeration compressor oil