01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme

Regulatory Identifiers

CAS Number
N/A
REACH No.
not applicable

Identified Uses

Fog and smoke simulation

Manufacturers & Suppliers

Steinigke Showtechnic GmbH logo

Steinigke Showtechnic GmbH

manufacturer

Andreas-Bauer-Straße 5, D-97297 Waldbüttelbrunn

+49 931 4061-0

http://www.steinigke.com

Emergency Contacts

Steinigke Showtechnic GmbH

+49 931 4061-434

Mo. – Fr., 8.00 – 16.00 Uhr

Giftnotruf Mainz

+49 6131 - 19240

24 h Notdienst

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Triethylene glycol EC: 203-953-2 127-27-6 50% No
1,2-Propanediol EC: 200-338-0 57-55-6 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Get medical advice/attention if you feel unwell.

Skin contact

Wash with plenty of soap and water.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Get medical advice/attention if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water (spray jet), Dry extinguishing agents, Carbon dioxide. Fight larger fires with alcohol-resistant foam or water spray.

Unsuitable media

Full water jet.

Specific hazards

Carbon monoxide and carbon dioxide

Firefighter Protection

Wear self-contained breathing apparatus for fire fighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep unprotected persons at a safe distance. Ensure adequate ventilation.

Environmental

The mixture is weakly water-endangering. Avoid further spillage or leakage prevented if this is possible without risk.

Cleanup methods

Absorb any spilt liquid with an absorbent (e.g. diatomite, vermiculite, sand) and dispose of according to regulations. Afterwards ventilate area and wash spill site.

Materials: diatomite, vermiculite, sand

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Store in unbreakable containers. Do no eat, drink or smoke when using this product. For vaporized liquid: concentration of smoke fluid in the air should be calculated between 25 and max. 80 mg/m³. A visibility of 25 meters must be complied with.

Storage

Store in a well-ventilated place. Keep container tightly closed. Protect from sunlight. Store at temperatures not exceeding 40 °C/104 °F. Keep cool. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Do no eat, drink or smoke when using this product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

not mandatory

Hands

Wear gloves when refilling. Suitable gloves are: Natural rubber/Natural latex - NR (0,5 mm) (use non-powdered and allergen free products) Polychloroprene - CR (0,5 mm) Nitrile rubber/Nitrile latex - NBR (0,35 mm) Butyl rubber - Butyl (0,5 mm) Fluoro carbon rubber - FKM (0,4 mm) Polyvinyl chloride - PVC (0,5 mm)

Eyes

Recommended during refilling. Use by official standards (NIOSH, EN 166) tested and approved equipment.

Respiratory

not mandatory

Skin/Body

The protection clothing should be solvent resistant.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Data not available
Vapor Density
---
Upper Explosive Limit
Data not available
Odor
neutral
Molecular Weight
---
Kinematic Viscosity
---
Melting Point
-5 °C
Ph
6-8
Boiling Point
from 100 °C
Flash Point
101 °C
Physical State
liquid
Appearance
liquid, colourless
Relative Density
1,02 g/ml
Physical State Data
liquid
Bulk Density
---
Solidification Point
---
Crystallisation Point
---
Solubility
miscible in water
Odor Threshold
Data not available
Solubility In Fat
---
Explosive Limits
---
Vapor Pressure
---
Cloud Point
---
Auto Ignition Temperature
Data not available
Solubility In Water
miscible in water
Dynamic Viscosity
49,4 mPa*s at 20 °C
Flammability
Data not available
Voc Content
---
Evaporation Rate
Data not available
Form
liquid
Decomposition Temperature
Data not available
Colour Intensity
---
Metal Corrosion
---
Relative Evaporation Rate
---
Properties Status
---
Lower Explosive Limit
Data not available
Colour
colourless
Density
---
Freezing Point
---
State Under Standard Conditions
---
Softening Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

see section 10.3.

Hazardous reactions

Reacts with strong alkalis. Reacts with oxidants.

Avoid

Protect from sunlight. Do not expose to temperatures exceeding 40°C / 104°F.

Incompatible

see section 10.3.

Decomposition

Does not decompose during the intended use. In the event of fire: see section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Non dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme?

The signal word is no signal word.

What is the physical form of EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme?

EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme is a liquid appearing as liquid, colourless with colourless color. It has neutral odor.

What is the solubility of EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme?

miscible in water

What is EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme used for?

Fog and smoke simulation

What is the melting point of EUROLITE Smoke fluid -A2D- Action smoke fluid, EUROLITE Smoke fluid -B2D- basic, EUROLITE Smoke fluid -C2D- standard, EUROLITE Smoke fluid -P2D- professional, EUROLITE Smoke fluid -E2D- extreme?

The melting point is -5 °C and the boiling point is from 100 °C.