Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- All Melin Tool Cemented Tungsten Carbide and Cermet Tools
- Product Form
- Article
- Synonyms
- Carbide Cutting Tools
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
No additional information available
Manufacturers & Suppliers
Melin Tool Co.
manufacturer
5565 Venture Dr., Unit C, Cleaveland, OH 44130
216-362-4200
http://www.melintool.com
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Tungsten carbide | 12070-12-1 | 10 - 94% | No |
| Titanium carbide (TiC) | 12070-08-5 | 0.2 - 53% | No |
| Cobalt | 7440-48-4 | 20% | Yes |
| Nickel | 7440-02-0 | 15% | Yes |
| Tantalum carbide (TaC) | 12070-06-3 | 15% | No |
| Niobium carbide (Nb2C) | 12011-99-3 | 5% | No |
| Chromium | 7440-47-3 | 3% | Yes |
| Chromium carbide (Cr3C2) | 12012-35-0 | 3% | No |
| Aluminum oxide | 1344-28-1 | 2% | No |
| Boron oxide (B2O3) | 1303-86-2 | 2% | Yes |
| Zirconium | 7440-67-7 | 2% | Yes |
| Molybdenum | 7439-98-7 | 2% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
When symptoms occur: go into open air and ventilate suspected area. Obtain medical attention if breathing difficulty persists.
Symptoms: Dust from this product may cause irritation to the respiratory tract.
Wash with plenty of soap and water. Obtain medical attention if irritation develops or persists.
Symptoms: Dust may cause irritation in skin folds or by contact in combination with tight clothing. Skin exposure can cause an allergic red rash (cobalt itch).
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Symptoms: Eye contact with dust may cause mechanical irritation.
If substantial quantities are swallowed, dilute with large amount of water. Induce vomiting and seek medical attention.
Symptoms: Ingestion is likely to be harmful or have adverse effects.
Immediate Medical Attention
If medical advice is needed, have product container or label at hand.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical powder, alcohol-resistant foam, carbon dioxide (CO₂).
Do not use a heavy water stream. Use of heavy stream of water may spread fire.
Fire Hazard: Not considered flammable but may burn at high temperatures. Explosion Hazard: Dusts may present a fire or explosion hazard under rare favoring conditions of particle size, dispersion, concentration, and strong ignition source. However, this is not expected to be a problem under normal handling conditions.
Do not breathe fumes or vapors from fire.
Firefighter Protection
For a dust fire confined to a small area, use a respirator approved for toxic dusts and fumes. For a large fire involving this material, fire fighters should use a self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Eliminate ignition sources. Ventilate area.
Prevent entry to sewers and public waters.
Clean up spills immediately and dispose of waste safely. Use HEPA vacuum or thoroughly wet with water to clean-up dust. Transfer spilled material to a suitable container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use care during processing to minimize generation of dust. Avoid dust production that exceeds permissible exposure limits.
Store in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety procedures. Wash hands and other exposed areas with mild soap and water before eating, drinking, or smoking and again when leaving work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use local exhaust or general dilution ventilation or other suppression methods to maintain dust levels below exposure limits. Power equipment should be equipped with proper dust collection devices. Ensure all national/local regulations are observed.
Chemically resistant gloves are recommended, but not required.
Chemical safety goggles.
If exposure limits are exceeded or irritation is experienced, approved respiratory protection should be worn.
Wear suitable protective clothing. Chemically resistant materials and fabrics.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at standard temperature and pressure.
Hazardous reactions will not occur under normal conditions.
Hazardous polymerization will not occur.
Not available
Strong acids. Strong bases. Strong oxidizers. Contact of dust with strong oxidizers may cause fire or explosion.
Oxides of aluminum. Oxides of cobalt. Oxides of titanium. Oxides of tungsten. Carbon oxides (CO, CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is All Melin Tool Cemented Tungsten Carbide and Cermet Tools known by?
All Melin Tool Cemented Tungsten Carbide and Cermet Tools is also known as: Carbide Cutting Tools
What is the hazard signal word for All Melin Tool Cemented Tungsten Carbide and Cermet Tools?
The signal word is no signal word.
What is the physical form of All Melin Tool Cemented Tungsten Carbide and Cermet Tools?
All Melin Tool Cemented Tungsten Carbide and Cermet Tools is a solid appearing as dark gray . It has odorless odor.
What is the solubility of All Melin Tool Cemented Tungsten Carbide and Cermet Tools?
Insoluble.
What is All Melin Tool Cemented Tungsten Carbide and Cermet Tools used for?
No additional information available
What is the melting point of All Melin Tool Cemented Tungsten Carbide and Cermet Tools?
The melting point is 5045 °C (9113 °F) and the boiling point is No data available.