01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Luconyl® Yellow 0911
Product Code
30277530

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Colorants for the Paints, lacquers and varnishes industry

Manufacturers & Suppliers

B

BASF SE

manufacturer

67056 Ludwigshafen, GERMANY

+49 621 60-45891

Emergency Contacts

International emergency number

+49 180 2273-112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

EUH070 The product does not require a hazard warning label in accordance with GHS criteria.
EUH209 The product does not require a hazard warning label in accordance with EC Directives.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Preparation based on: pigment, in water/solvent C.I. Pigment Yellow 3

Chemical Name CAS Number Concentration Hazardous
C.I. Pigment Yellow 3 --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention.

Skin contact

Wash thoroughly with soap and water.

Eye contact

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

Ingestion

Rinse mouth and then drink plenty of water.

Medical Treatment

Treat according to symptoms (decontamination, vital functions), no known specific antidote.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water spray, dry powder, foam

Specific hazards

harmful vapours, Evolution of fumes/fog. The substances/groups of substances mentioned can be released in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective clothing.

Small spill

For residues: Pick up with suitable absorbent material.

Large spill

For large amounts: Pump off product.

Environmental

Contain contaminated water/firefighting water. Do not discharge into drains/surface waters/groundwater.

Cleanup methods

Pump off product. Pick up with suitable absorbent material.

Materials: suitable absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary provided product is used correctly. Protect against heat.

Storage

Keep container tightly closed and in a cool place. Store protected against freezing.

Fire prevention

No special precautions necessary.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical resistant protective gloves (EN 374) Suitable materials also with prolonged, direct contact (Recommended: Protective index 6, corresponding > 480 minutes of permeation time according to EN 374): e.g. nitrile rubber (0.4 mm), chloroprene rubber (0.5 mm), polyvinylchloride (0.7 mm) and other Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing. Manufacturer's directions for use should be observed because of great diversity of types.

Eyes

Safety glasses with side-shields (frame goggles) (e.g. EN 166)

Respiratory

Respiratory protection in case of vapour/aerosol release. Particle filter with medium efficiency for solid and liquid particles (e.g. EN 143 or 149, Type P2 or FFP2)

Skin/Body

Due to the colouring properties of the product closed work clothes should be used, to avoid stains during manipulation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid yellow
Colour
yellow
Colour Intensity
---
Form
liquid
Odor
product specific
Odor Threshold
not determined
Ph
approx. 8 - 9 (20 °C)
Melting Point
---
Boiling Point
approx. 100 °C
Flash Point
> 100 °C (DIN 51758)
Freezing Point
---
Softening Point
---
Solidification Point
< 0 °C
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
not determined
Vapor Density
---
Relative Density
Study does not need to be conducted.
Bulk Density
---
Density
approx. 1.1 - 1.2 g/cm3 (20 °C)
Flammability
does not ignite
Upper Explosive Limit
As a result of our experience with this product and our knowledge of its composition we do not expect any hazard as long as the product is used appropriately and in accordance with the intended use.
Lower Explosive Limit
As a result of our experience with this product and our knowledge of its composition we do not expect any hazard as long as the product is used appropriately and in accordance with the intended use.
Explosive Limits
---
Auto Ignition Temperature
> 200 °C (DIN 51794)
Decomposition Temperature
---
Solubility
---
Partition Coefficient
not applicable
Solubility In Water
miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
not determined
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable if stored and handled as prescribed/indicated.

Reactivity

No hazardous reactions if stored and handled as prescribed/indicated.

Hazardous reactions

No hazardous reactions when stored and handled according to instructions.

Avoid

No special precautions other than good housekeeping of chemicals.

Incompatible

No substances known that should be avoided.

Decomposition

No hazardous decomposition products if stored and handled as prescribed/indicated.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Luconyl® Yellow 0911?

The signal word is no signal word.

What is the physical form of Luconyl® Yellow 0911?

Luconyl® Yellow 0911 is a liquid appearing as liquid yellow with yellow color. It has product specific odor.

What is Luconyl® Yellow 0911 used for?

Colorants for the Paints, lacquers and varnishes industry

What are the hazard statements for Luconyl® Yellow 0911?

This substance has 2 hazard statements:

  • EUH070: The product does not require a hazard warning label in accordance with GHS criteria.
  • EUH209: The product does not require a hazard warning label in accordance with EC Directives.