Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LUBRIZOL® 8405A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Viscosity Improvers
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL FRANCE
25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR
(33) 02.35.58.14.00
www.mylubrizol.com
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
Emergency Contact
09.75.18.14.07
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 1 - 10% | Yes |
Notes
600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only. The full text for all H-phrases is displayed in section 16. See Section 15 for Regulation (EC) No. 1907/2006 REACH Article 59(1). Candidate List (Substances of Very High Concern (SVHC))
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention.
Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
If irritation occurs (eyes, skin) or symptoms occur (ingestion), get medical assistance/attention. Treat symptomatically.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, dry chemical, foam, water spray, water fog.
Do not use water jet as an extinguisher, as this will spread the fire.
A solid stream of water will spread the burning material. Material creates a special hazard because it floats on water. See section 10 for additional information.
No data available.
Firefighter Protection
Recommend wearing self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Personal Protective Equipment must be worn, see Personal Protection Section for PPE recommendations. Ventilate area if spilled in confined space or other poorly ventilated areas.
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Do not contaminate water sources or sewer. Environmental manager must be informed of all major spillages. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear appropriate personal protective equipment. In case of spills, beware of slippery floors and surfaces.
Store away from incompatible materials.
Observe good industrial hygiene practices.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation should be provided so that exposure limits are not exceeded.
Use nitrile or neoprene gloves. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. Breakthrough time data are generated by glove manufacturers under laboratory test conditions and represent how long a glove can be expected to provide effective permeation resistance. It is important when following breakthrough time recommendations that actual workplace conditions are taken into account. Always consult with your glove supplier for up-to-date technical information on breakthrough times for the recommended glove type. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. If suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to. For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. Therefore, appropriate maintenance and replacement regimes must be determined and rigorously followed. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. It is important to note that glove thickness is not the only predictor of glove resistance to a specific chemical, as the permeation efficiency of the glove will be dependent on the exact composition of the glove material. Therefore, glove selection should also be based on consideration of the task requirements and knowledge of breakthrough times. Glove thickness may also vary depending on the glove manufacturer, the glove type and the glove model. Therefore, the manufacturers’ technical data should always be taken into account to ensure selection of the most appropriate glove for the task. Depending on the activity being conducted, gloves of varying thickness may be required for specific tasks. For example: Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. However, these gloves are only likely to give short duration protection and would normally be just for single use applications, before being disposed of. Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use respirator with a dust/mist cartridge if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Please refer to the relevant EN standards for the RPE selected.
No data available.
No data available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Will not occur.
Do not expose to excessive heat, ignition sources, or oxidizing materials. Excessive heat. Open flames and high energy ignition sources.
Strong acids. Strong oxidizing agents.
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LUBRIZOL® 8405A?
The signal word is no signal word.
What is the physical form of LUBRIZOL® 8405A?
LUBRIZOL® 8405A is a liquid with colorless color. It has mild odor.
What is the solubility of LUBRIZOL® 8405A?
No data available.
What is LUBRIZOL® 8405A used for?
Viscosity Improvers