NextSDS Logo
Safety Data Sheet EN

Epoxy curing agent

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Epoxy curing agent
Product Code
Cardolite NC-562

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites; PC9a Coatings and paints, thinners, paint removers; Coating

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

C

CARDOLITE SPECIALTY CHEMICALS EUROPE N.V.

manufacturer

Wijmenstraat 21 K , Bus 2 9030 Mariakerke – Gent

+32 9 265.88.26

Emergency Contacts

Emergency Contact

+32 9 265.88.26

During business hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Eye Dam. Cat. 1 H318
Skin Irrit. Cat. 2 H315

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

Hazard Statements

H226 Flammable liquid and vapour.
H315 Causes skin irritation.
H318 Causes serious eye damage.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read label before use.
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P241 Use explosion-proof electrical/ventilating/lighting/equipment.
P303 + P361 + P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER or doctor/physician.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
xylene EC: 215-535-7 1330-20-7 25 - 28% Yes
butanol EC: 200-751-6 71-36-3 6.5 - 9.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, sand, extinguishing powder.

Unsuitable media

Water with full jet

Instructions

Promptly isolate the scene by removing all person from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.

Storage

No special requirements.

Fire prevention

Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Yellow-brown
Colour Intensity
---
Form
Liquid
Odor
Amine-like
Odor Threshold
Not determined.
Ph
10,5
Melting Point
Undetermined.
Boiling Point
66 °C
Flash Point
32 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
6,7 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
0,9646 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
7,0 Vol %
Lower Explosive Limit
1,1 Vol %
Explosive Limits
---
Auto Ignition Temperature
340 °C
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
35,00 %
Metal Corrosion
---
Dynamic Viscosity
1500 cps
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1866
Shipping Name
RESIN SOLUTION
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Epoxy curing agent?

The signal word is danger.

What is the physical form of Epoxy curing agent?

Epoxy curing agent is a liquid with yellow-brown color. It has amine-like odor.

What is Epoxy curing agent used for?

SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites; PC9a Coatings and paints, thinners, paint removers; Coating

What are the hazard statements for Epoxy curing agent?

This substance has 3 hazard statements:

  • H226: Flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.

What is the melting point of Epoxy curing agent?