NextSDS Logo
Safety Data Sheet EN

Glycerol 87%

CAS 56-81-5
EC 200-289-5

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Glycerol 87%
Product Code
1343
Chemical Name
Glycerol

Regulatory Identifiers

CAS Number
56-81-5 Check regulations →
EC Number
200-289-5 Check regulations →
REACH No.
01-2119471987-18-XXXX

Identified Uses

For use in laboratory and production. Not for human or animal use. For Professional users only.

Uses advised against

All uses not specified in this section or in

Manufacturers & Suppliers

GERBU Biotechnik GmbH logo

GERBU Biotechnik GmbH

manufacturer

69123 Heidelberg - Germany

+49 6221 7264167

http://www.gerbu.de

Emergency Contacts

Eire

01809 2566

Emergency call (EU)

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Glycerol EC: 200-289-5 56-81-5 75 - 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of symptoms, move the person affected into fresh air.

Skin contact

In case of contact it is recommended to clean the affected area thoroughly with water and neutral soap.

Symptoms: stinging, redness, rashes, blisters

Eye contact

Rinse with water until the product has been eliminated.

Ingestion

In case of consumption in large quantities, it is recommended to seek medical assistance.

Immediate Medical Attention

In case of changes to the skin (stinging, redness, rashes, blisters,…), seek medical advice with this Safety Data Sheet. In case of problems (eye contact), consult a doctor showing the SDS for the product.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product is non-flammable under normal conditions of storage, handling and use. In the case of combustion as a result of improper handling, storage or use preferably use polyvalent powder extinguishers (ABC powder), in accordance with the Regulation on fire protection systems.

Unsuitable media

Non-applicable

Specific hazards

Due to its non-inflammable nature, the product does not present a fire risk under normal conditions of storage, handling and use.

Instructions

Act in accordance with the Internal Emergency Plan and the Information Sheets on actions to take after an accident or other emergencies. Eliminate all sources of ignition. In case of fire, cool the storage containers and tanks for products susceptible to combustion, explosion or BLEVE as a result of high temperatures.

Firefighter Protection

Depending on the magnitude of the fire it may be necessary to use full protective clothing and Self Contained Breathing Apparatus. Minimum emergency facilities and equipment should be available (fire blankets, portable first aid kit,...)

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate leaks provided that there is no additional risk for the people performing this task. For emergency responders: Wear protective equipment. Keep unprotected persons away. See section 8.

Small spill

Contain spillage using barriers or similar equipment. Use suitable absorbents for collection and treat the waste in accordance with current regulations.

Large spill

If possible, contain spillage in open water using barriers or similar equipment. If this is not possible, try to control its spread and collect the product with suitable mechanical means. Always consult experts before using dispersants and make sure you have the necessary approvals if they are to be used. Treat the waste according to current regulations.

Environmental

This product is not classified as hazardous to the environment.

Cleanup methods

Absorb the spill using sand or inert absorbent and move it to a safe place. Collect the product in appropriate containers and manage it according to current legislation.

Materials: sand or inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Comply with the current legislation concerning the prevention of industrial risks with regards manually handling weights. Maintain order, cleanliness and dispose of using safe methods (section 6).

Storage

Avoid sources of heat, radiation, static electricity and contact with food.

Hygiene

Do not eat or drink during the process, washing hands afterwards with suitable cleaning products.

Fire prevention

It is recommended to transfer at a slow speed to avoid the creation of electrostatic charges that could affect flammable products.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Not relevant

Eyes

Not relevant

Respiratory

If the working conditions and/or safety measures adopted do not allow keeping the airborne concentration of the product below the exposure limits (if any) or at acceptable levels (if no exposure limits exist), suitable respiratory protection equipment chosen by a qualified professional should be used.

Skin/Body

Not relevant

Environmental

To comply with environmental protection regulations, it is recommended to prevent any spillage of the product and its container. For more detailed information, please refer to sub section 7.1.D.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
1,226
Freezing Point
---
Ph
Not relevant
Odor
Not relevant
Lower Explosive Limit
Not relevant
Form
---
Properties Status
---
Dynamic Viscosity
1600 mPa·s
Appearance
---
Colour
Not relevant
Boiling Point
100 ºC
Molecular Weight
---
Upper Explosive Limit
Not relevant
Flammability
---
Bulk Density
---
Solidification Point
---
Flash Point
Non Flammable (>60 ºC)
Physical State Data
liquid
Evaporation Rate
Not relevant
Softening Point
---
Relative Evaporation Rate
---
Melting Point
Not relevant
Auto Ignition Temperature
Not relevant
Vapor Pressure
2350 Pa
Kinematic Viscosity
1305,44 mm²/s
Density
1225,6 kg/m³
Vapor Density
---
Explosive Limits
---
Physical State
---
Decomposition Temperature
Not relevant
Cloud Point
---
Solubility
---
State Under Standard Conditions
---
Partition Coefficient
Not relevant
Voc Content
---
Solubility In Water
Not relevant
Solubility In Fat
---
Crystallisation Point
---
Colour Intensity
---
Odor Threshold
Not relevant
Metal Corrosion
Not relevant
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

stable under recommended storage conditions

Reactivity

No hazardous reactions are expected because the product is stable under recommended storage conditions.

Hazardous reactions

No hazardous reactions are expected

Avoid

Applicable for handling and storage at room temperature

Incompatible

Strong acids, Water, Oxidising materials, Combustible materials, Alkalis or strong bases

Decomposition

See subsection 5.2, complex mix of decomposition products

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Glycerol 87%?

The signal word is no signal word.

What is Glycerol 87% used for?

For use in laboratory and production. Not for human or animal use. For Professional users only.

What is the melting point of Glycerol 87%?

The melting point is Not relevant and the boiling point is 100 ºC.