NextSDS Logo
Safety Data Sheet EN

n-Propylmethyldimethoxysilane

CAS 18173-73-4

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
n-Propylmethyldimethoxysilane
Product Code
S14030
Chemical Name
n-Propylmethyldimethoxysilane

Regulatory Identifiers

CAS Number
18173-73-4 Check regulations →

Identified Uses

Research and Development

Manufacturers & Suppliers

F

Fluorochem Ltd

manufacturer

Unit 14, Graphite Way, Hadfield, Derbyshire, SK13 1QH, UK

+44(0)1457 860111

Emergency Contacts

Emergency Contact

+44(0)7855 268577

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. A H335

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highlyflammable liquid and vapour.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 Maycause respiratoryirritation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

n-Propylmethyldimethoxysilane

Chemical Name CAS Number Concentration Hazardous
n-Propylmethyldimethoxysilane 18173-73-4 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.

Symptoms: Skin irritation

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Symptoms: Eye irritation

Ingestion

Wash out mouth with water.

Immediate Medical Attention

If skin irritation occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use sand, CO2 or powdered extinguishing agent for extinction.

Unsuitable media

Do not use water.

Specific hazards

In combustion toxic fumes may form.

Firefighter Protection

Wear self-contained breathing apparatus. Wear protective clothing to prevent contact with skin and eyes.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Refer to section 8 of SDS for personal protection details. Do not attempt to take action without suitable protective clothing – see section 8 of SDS.

Environmental

Do not discharge into drains or rivers. Contain the spillage using bunding.

Cleanup methods

Transfer to a closable, labelled salvage container for disposal by an appropriate method.

Materials: closable, labelled salvage container

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure there is sufficient ventilation of the area. P264: Wash hands thoroughly after handling. P362: Take off contaminated clothing and wash before reuse.

Storage

Store in cool, well ventilated area. Keep container tightly closed. P233: Keep container tightly closed. P235: Keep cool.

Hygiene

P264: Wash hands thoroughly after handling. P362: Take off contaminated clothing and wash before reuse.

Fire prevention

P240: Ground/bond container and receiving equipment. P243: Take precautionary measures against static discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

P271: Use only outdoors or in a well-ventilated area. Ensure lighting and electrical equipment are not a source of ignition.

Hands

Protective gloves.

Eyes

Safety Glasses with side-shields.

Respiratory

P260: Do not breathe dust/fume/gas/mist/vapours/spray. Use breathing protection with high concentrations

Skin/Body

Handle with gloves. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practice. Wash and dry hands. Protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear colourless liquid
Colour
colourless
Colour Intensity
---
Form
liquid
Odor
Alcoholic
Odor Threshold
No Data Available
Ph
No Data Available
Melting Point
No Data Available
Boiling Point
126°C
Flash Point
No Data Available
Freezing Point
No Data Available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No Data Available
Vapor Pressure
No Data Available
Vapor Density
No Data Available
Relative Density
0.87
Bulk Density
---
Density
---
Flammability
No Data Available
Upper Explosive Limit
No Data Available
Lower Explosive Limit
No Data Available
Explosive Limits
---
Auto Ignition Temperature
No Data Available
Decomposition Temperature
No Data Available
Solubility
No Data Available
Partition Coefficient
No Data Available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Heating in the presence of oxygen above 200 C may cause the formation of formaldehyde.

Hazardous reactions

no hazardous reactions known

Avoid

Heating above 200 C in the presence of oxygen.

Incompatible

Oxidising agents.

Decomposition

Formaldehyde, oxides of nitrogen, carbon and silicon.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1993
Shipping Name
Flammable liquid, n.o.s.
Transport Class
3
Packing Group
II
ADR

For the purposes of documentation and package marking, the Proper Shipping Name shall be supplemented with the technical name (see 3.1.2.8.1).

IMDG

This substance, when containing less alcohol, water or phlegmatizer than specified, shall not be transported, unless specifically authorized by the competent authority.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for n-Propylmethyldimethoxysilane?

The signal word is danger.

What is the physical form of n-Propylmethyldimethoxysilane?

n-Propylmethyldimethoxysilane is a liquid appearing as clear colourless liquid with colourless color. It has alcoholic odor.

What is the solubility of n-Propylmethyldimethoxysilane?

No Data Available

What is n-Propylmethyldimethoxysilane used for?

Research and Development

What are the hazard statements for n-Propylmethyldimethoxysilane?

This substance has 4 hazard statements:

  • H225: Highlyflammable liquid and vapour.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: Maycause respiratoryirritation.

What is the melting point of n-Propylmethyldimethoxysilane?

The melting point is No Data Available and the boiling point is 126°C.