NextSDS Logo
Safety Data Sheet EN

Propylmethyldichlorosilane

CAS 4518-94-9
EC 224-843-0

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Propylmethyldichlorosilane
Product Code
S14025
Synonyms
Methyl-n-propyldichlorosilane

Regulatory Identifiers

CAS Number
4518-94-9 Check regulations →
EC Number
224-843-0 Check regulations →

Identified Uses

Research and Development

Manufacturers & Suppliers

F

Fluorochem Ltd

manufacturer

Unit 14, Graphite Way, Hadfield, Derbyshire, SK13 1QH, UK

+44(0)1457 860111

Emergency Contacts

Emergency Contact

+44(0)7855 268577

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. H226
Skin Corr. H314

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

Hazard Statements

H226 Flammable liquid and vapour.
H314 Causes severe skin burns and eye damage.

Precautionary Statements

P280 Wearprotectivegloves/protective clothing/eyeprotection/faceprotection.
P301 + P330 + P331 IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
P303 + P361 + P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340 IF INHALED: Remove victim to fresh air and keepat rest in aposition comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easyto do. Continue rinsing.
P370 + P378 In case of fire: Use sand,CO2 or extinguishing powder for extinction.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Propylmethyldichlorosilane 4518-94-9 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

P304 + P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

P303 + P361 + P353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.

Eye contact

P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

P301 + P330 + P331: IF SWALLOWED: rinse mouth. Do NOT induce vomiting. Wash out mouth with water.

Immediate Medical Attention

No additional measures required

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use sand, CO2 or extinguishing powder for extinction.

Unsuitable media

no data

Specific hazards

In combustion toxic fumes may form.

Firefighter Protection

Wear self-contained breathing apparatus. Wear protective clothing to prevent contact with skin and eyes.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Eliminate all sources of ignition. Do not attempt to take action without suitable protective clothing – see section 8 of SDS.

Environmental

Do not discharge into drains or rivers. Contain the spillage using bunding.

Cleanup methods

Mix with sand or vermiculite. Transfer to a closable, labelled salvage container for disposal by an appropriate method.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure there is sufficient ventilation of the area. P240: Ground/bond container and receiving equipment. P264: Wash hands thoroughly after handling. P363: Wash contaminated clothing before reuse.

Storage

Store in cool, well ventilated area. Keep away from direct sunlight. Store under inert gas.

Hygiene

P264: Wash hands thoroughly after handling. P363: Wash contaminated clothing before reuse.

Fire prevention

P242: Use only non-sparking tools. P243: Take precautionary measures against static discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure there is sufficient ventilation of the area.

Hands

Protective gloves.

Eyes

Safety Glasses with side-shields.

Respiratory

Do not breathe dust/fume/gas/mist/vapours/spray. Use breathing protection with high concentrations.

Skin/Body

Handle with gloves. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practice. Wash and dry hands. Protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Light brown liquid
Colour
Light brown
Colour Intensity
---
Form
liquid
Odor
No Data Available
Odor Threshold
No Data Available
Ph
No Data Available
Melting Point
No Data Available
Boiling Point
125°C
Flash Point
27 °C - closed cup
Freezing Point
No Data Available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No Data Available
Vapor Pressure
No Data Available
Vapor Density
No Data Available
Relative Density
1.046g/mL at 20 °C
Bulk Density
---
Density
---
Flammability
No Data Available
Upper Explosive Limit
No Data Available
Lower Explosive Limit
No Data Available
Explosive Limits
---
Auto Ignition Temperature
No Data Available
Decomposition Temperature
No Data Available
Solubility
No Data Available
Partition Coefficient
No Data Available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

no unusual reactivity

Hazardous reactions

no hazardous reactions known

Avoid

Moisture sensitive.

Incompatible

Oxidising agents. Bases.

Decomposition

In combustion emits toxic fumes. In combustion emits toxic fumes of hydrogen chloride / phosgene. In combustion emits toxic fumes of formaldehyde. In combustion emits toxic fumes of organic acid vapors. In combustion emits toxic fumes of carbon monoxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
2986
Shipping Name
Chlorosilanes, corrosive, flammable, n.o.s.
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Propylmethyldichlorosilane known by?

Propylmethyldichlorosilane is also known as: Methyl-n-propyldichlorosilane

What is the hazard signal word for Propylmethyldichlorosilane?

The signal word is danger.

What is the physical form of Propylmethyldichlorosilane?

Propylmethyldichlorosilane is a liquid appearing as light brown liquid with light brown color. It has no data available odor.

What is the solubility of Propylmethyldichlorosilane?

No Data Available

What is Propylmethyldichlorosilane used for?

Research and Development

What are the hazard statements for Propylmethyldichlorosilane?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H314: Causes severe skin burns and eye damage.

What is the melting point of Propylmethyldichlorosilane?