Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ransel
- Product Code
- RS504
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For in vitro diagnostic use only. Do not pipette by mouth. Handle laboratory reagents in accordance with Good Laboratory Practice.
Manufacturers & Suppliers
Randox Laboratories Ltd.
manufacturer
55 Diamond Road, Crumlin, Co. Antrim, United Kingdom, BT29 4QY
+44 (0) 28 9442 2413
http://www.randox.com
Emergency Contacts
Emergency Contact
+44 (0) 28 9442 2413
GMT, English spoken, Mon - Fri. 08.40-17.20
EN
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS06
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| R1a. Reagent and R1b. Buffer | --- | --- | No |
| Cumene hydroperoxide | 80-15-9 | 50 - 100% | Yes |
| Cumene | 98-82-8 | 20 - 25% | Yes |
| 2-Phenylpropan-2-ol | 617-94-7 | 10% | Yes |
| Sodium azide | 26628-22-8 | 1 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, move victim to fresh air, rest and maintain a half-upright position. Use artificial respiration if necessary.
If skin contact occurs, remove contaminated clothes, rinse skin with plenty of cold water or shower.
If eye contact occurs, first rinse with plenty of cold water for several minutes.
If ingested, rinse mouth. Give plenty of water to drink.
Immediate Medical Attention
Immediately seek medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
As appropriate for the surrounding fire
May emit toxic fumes under fire conditions.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation.
Not determined
Mop up with an absorbent material and hold for waste disposal.
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment (refer to section 8.2.2). Wash thoroughly after handling. Do not use if skin is cut or scratched. Avoid contact with eyes, skin and clothing. Do not eat, drink or smoke when using this product.
Store at temperatures and conditions as indicated on the product label.
Wash thoroughly after handling. Do not eat, drink or smoke when using this product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation.
Standard laboratory rubber or latex gloves
Approved safety glasses
Face mask
A laboratory coat is recommended
Not determined
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions
Not determined
Not determined
Not determined
Not determined
Not determined
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ransel?
The signal word is danger.
What is the physical form of Ransel?
Ransel is a r1a. reagent - solid r1b. buffer - liquid r2. cumene hydroperoxide - liquid r3. diluting agent - solid appearing as r1a. reagent - solid r1b. buffer - liquid r2. cumene hydroperoxide - liquid r3. diluting agent - solid with r1a. reagent - red/brown r1b. buffer - colourless r2. cumene hydroperoxide - colourless r3. diluting agent - pale yellow color. It has not determined odor.
What is the solubility of Ransel?
Not determined
What is Ransel used for?
For in vitro diagnostic use only. Do not pipette by mouth. Handle laboratory reagents in accordance with Good Laboratory Practice.
What are the hazard statements for Ransel?
This substance has 10 hazard statements:
- H242: Heating may cause a fire
- H302: Harmful if swallowed
- H302 + H312: Harmful if swallowed or in contact with skin
- H304: May be fatal if swallowed and enters airways
- H314: Causes severe burns and eye damage
- H331: Toxic if inhaled
- H335: May cause respiratory irritation
- H373: May cause damage to organs through prolonged or repeated exposure
- H411: Toxic to aquatic life with long lasting effects
- H412: Harmful to aquatic life with long lasting effects
What is the melting point of Ransel?