Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Decalcifier DC3 Q path® rapid-acting
- Product Code
- 09128300
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
distributor
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrochloric acid EC: 231-595-7 | 7647-01-0 | 5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration. In case of respiratory tract irritation, consult a physician.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. In case of skin reactions, consult a physician.
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
If accidentally swallowed rinse the mouth with plenty of water (only if the person is conscious) and obtain immediate medical attention. Do NOT induce vomiting. Give nothing to eat or drink.
Immediate Medical Attention
In case of respiratory tract irritation, consult a physician. In case of skin reactions, consult a physician. In case of contact with eyes, consult an ophthalmologist. If accidentally swallowed, obtain immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product itself does not burn. Co-ordinate fire-fighting measures to the fire surroundings.
no restriction
In case of fire may be liberated: Pyrolysis products, toxic
Use water spray jet to protect personnel and to cool endangered containers.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe gas/vapour/aerosol. Provide adequate ventilation. Use personal protection equipment. In case of major fire and large quantities: Remove persons to safety.
In case of major fire and large quantities: Remove persons to safety. Wear a self-contained breathing apparatus and chemical protective clothing.
Do not allow to enter into surface water or drains. Make sure spills can be contained, e.g. in sump pallets or kerbed areas. Discharge into the environment must be avoided.
Clean contaminated articles and floor according to the environmental legislation.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
All work processes must always be designed so that the following is as low as possible: Inhalation skin contact Eye contact
Keep container tightly closed and in a well-ventilated place.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms: EN ISO 374. In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,12 mm, Breakthrough time (maximum wearing time): > 480 min, Recommended glove articles: VWR 112-0998. By long-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,38 mm, Breakthrough time (maximum wearing time): > 480 min, Recommended glove articles: VWR 112-3717 / 112-1381
Eye glasses with side protection DIN-/EN-Norms: DIN EN 166. Recommendation: VWR 111-0432
Respiratory protection necessary at: aerosol or mist formation. Suitable respiratory protection apparatus: Full-/half-/quarter-face masks (DIN EN 136/140). Recommendation: VWR 111-0206. Suitable material: ABEK2P3. Recommendation: VWR 111-0059
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
no data available
no data available
no data available
no data available
no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1760
- Shipping Name
- CORROSIVE LIQUID, N.O.S. (HYDROCHLORIC ACID)
- Transport Class
- 8
- Packing Group
- III
Passage forbidden through tunnels of category E.
Segregation group: 1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Decalcifier DC3 Q path® rapid-acting?
The signal word is warning.
What is the physical form of Decalcifier DC3 Q path® rapid-acting?
Decalcifier DC3 Q path® rapid-acting is a liquid appearing as liquid with no data available color. It has no data available odor.
What is Decalcifier DC3 Q path® rapid-acting used for?
General chemical reagent
What are the hazard statements for Decalcifier DC3 Q path® rapid-acting?
This substance has 1 hazard statement:
- H290: May be corrosive to metals.
What is the melting point of Decalcifier DC3 Q path® rapid-acting?
The melting point is no data available and the boiling point is no data available.