Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HSi Hemolysis & Wash Solution
Product Form
Mixture
Product Code
HSi Hemolysis & Wash Solution-(L): 018431L, HSi Hemolysis & Wash Solution-(LL): 019550L

Regulatory Identifiers

CAS Number
N/A

Identified Uses

IN VITRO DIAGNOSTIC USE ONLY

Uses advised against

No additional information available

Manufacturers & Suppliers

T

Tosoh Europe NV

distributor

Transportstraat 4, 3980 Tessenderlo - Belgium

+32 13 66 88 30

Emergency Contacts

National Poisons Information Centre Beaumont Hospital

+353 1 809 2566

Healthcare professionals-24/7

National Poisons Information Centre Beaumont Hospital

+353 1 809 2166

public, 8am - 10pm, 7/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
tert-Octylphenoxy poly(oxyethylene)ethanol substance listed as REACH Candidate substance listed in REACH Annex XIV (4-(1,1,3,3-Tetramethylbutyl) phenol, ethoxylated (covering well-defined substances and UVCB substances, polymers and homologues)) substance identified as having endocrine disrupting properties EC: 618-344-0 9002-93-1 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. In case of doubt or persistent symptoms, consult always a physician.

Symptoms: Not expected to present a significant inhalation hazard under anticipated conditions of normal use.

Skin contact

Remove contaminated clothing and shoes. Gently wash with plenty of soap and water. In case of doubt or persistent symptoms, consult always a physician.

Symptoms: Not expected to present a significant skin hazard under anticipated conditions of normal use.

Eye contact

Rinse immediately carefully and thoroughly with eye-bath or water. In case of doubt or persistent symptoms, consult always a physician.

Symptoms: Not expected to present a significant eye contact hazard under anticipated conditions of normal use.

Ingestion

Rinse mouth thoroughly with water. Get medical advice/attention.

Symptoms: Not expected to present a significant ingestion hazard under anticipated conditions of normal use.

Immediate Medical Attention

In case of doubt or persistent symptoms, consult always a physician. Get medical advice/attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

carbon dioxide (CO2), powder, alcohol-resistant foam, water spray.

Unsuitable media

Strong water jet.

Specific hazards

Not flammable. Heating will cause a rise in pressure with a risk of bursting.

Instructions

Evacuate area. Use water spray or fog for cooling exposed containers. Contain the extinguishing fluids by bunding. Prevent fire fighting water from entering the environment.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Keep upwind. Provide adequate ventilation. Wear recommended personal protective equipment. Do not breathe vapours. Avoid contact with skin, eyes and clothing. Ensure procedures and training for emergency decontamination and disposal are in place.

Small spill

Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal.

Large spill

Recover large spills by pumping (use an explosion proof or hand pump).

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Stop leak if safe to do so. Dam up the liquid spill. Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal. Recover large spills by pumping (use an explosion proof or hand pump). Place in a suitable container for disposal in accordance with the waste regulations (see Section 13).

Materials: non-combustible absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide adequate ventilation. Use personal protective equipment as required. Concerning personal protective equipment to use, see section 8. Do not breathe vapours. Avoid contact with skin, eyes and clothing. Take any precaution to avoid mixing with Incompatible materials, Refer to Section 10 on Incompatible Materials. Ensure proper process control to avoid excess waste discharge (temperature, concentration, pH, time). Avoid release to the environment.

Storage

Bund storage facilities to prevent soil and water pollution in the event of spillage.

Hygiene

Keep good industrial hygiene. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Do not eat, drink or smoke when using this product. Keep away from food, drink and animal feedingstuffs. Remove contaminated clothes. Separate working clothes from town clothes. Launder separately. Wash contaminated clothing before reuse.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation. Organisational measures to prevent/limit releases, dispersion and exposure. See Section 7 for information on safe handling .

Hands

Wear chemically resistant gloves (tested to EN374) . Suitable material: Not determined. Thickness : Not determined. Breakthrough time : refer to the recommendations of the supplier. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances.

Eyes

Use suitable eye protection (EN166): Safety glasses with side shields

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. Half-face mask (DIN EN 140). full face mask (DIN EN 136). Filter type: A (EN 14387). The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. If the concentration is exceeded, self-contained breathing apparatus must be used. (EN 137)

Skin/Body

Wear suitable protective clothing

Environmental

Avoid release to the environment. Comply with applicable Community environmental protection legislation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flash Point
Not applicable
Ph
7,4
Physical State Data
liquid
Solidification Point
---
Odor Threshold
No data available
Decomposition Temperature
No data available
Evaporation Rate
---
Flammability
Not flammable
Form
---
Relative Density
No data available
Voc Content
---
Colour Intensity
---
Vapor Pressure
No data available
Boiling Point
No data available
Density
---
Solubility
Water: completely soluble
Upper Explosive Limit
---
Crystallisation Point
---
Vapor Density
No data available
Properties Status
---
Solubility In Fat
---
Bulk Density
---
Physical State
Liquid
Molecular Weight
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Cloud Point
---
Relative Evaporation Rate
No data available
Solubility In Water
completely soluble
Partition Coefficient
No data available
Melting Point
No data available
Appearance
liquid.
Auto Ignition Temperature
Not applicable
Lower Explosive Limit
---
Softening Point
---
Explosive Limits
---
Colour
Colourless.
Freezing Point
No data available
State Under Standard Conditions
---
Metal Corrosion
---
Odor
odourless.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at ambient temperature and under normal conditions of use.

Reactivity

Stable at ambient temperature and under normal conditions of use. Reference to other sections 10.4 & 10.5.

Hazardous reactions

No dangerous reactions known under normal conditions of use.

Avoid

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. See Section 7 for information on safe handling.

Incompatible

No information available. See Section 7 for information on safe handling.

Decomposition

Carbon oxides (CO, CO2).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HSi Hemolysis & Wash Solution?

The signal word is no signal word.

What is the physical form of HSi Hemolysis & Wash Solution?

HSi Hemolysis & Wash Solution is a liquid appearing as liquid. with colourless. color. It has odourless. odor.

What is the solubility of HSi Hemolysis & Wash Solution?

Water: completely soluble

What is HSi Hemolysis & Wash Solution used for?

IN VITRO DIAGNOSTIC USE ONLY

What is the melting point of HSi Hemolysis & Wash Solution?

The melting point is No data available and the boiling point is No data available.