Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]
- Product Code
- 5190-8588
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reference material for laboratory use only
Manufacturers & Suppliers
Agilent Technologies, Inc.
manufacturer
5301 Stevens Creek Blvd. Santa Clara, CA 95051 USA
800-227-9770
Emergency Contacts
CHEMTREC®
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Aqueous solution. Also contains substances at levels not considered to be hazardous.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrochloric acid | 7647-01-0 | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water.
Rinse mouth. Do not induce vomiting.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Formation of toxic gases is possible during heating or in case of fire.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective clothing.
Dilute with plenty of water.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Iridium ICP standard IrCl₃ in HCl 7% 1000 mg/l Ir Certipur®
---
Zirconium standard solution 1000 µg/ml (Plasma HIQU)
---
Chlorate standard solution 1000 µg/mL for IC (Ion HIQU)
CAS: 3811-04-9
Zirconium standard solution traceable to SRM from NIST ZrCl₄ in HCl 2 mol/l 1000 mg/l Zr Certipur®
---
Iron standard solution 1000 µg/ml (Plasma HIQU)
---
Nitrite standard solution 1000 µg/ml for IC (Ion HIQU)
CAS: 7632-00-0
Chromium ICP standard traceable to SRM from NIST Cr(NO₃)₃ in HNO₃ 2-3% 1000 mg/l Cr CertiPUR®
---
Iodine sublimated for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7553-56-2
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Store in cool, dry place in tightly closed receptacles.
Store in a cool location. Please refer to the manufacturers certificate for specific storage and transport temperature conditions. Store only in the original receptacle. Keep container in a well-ventilated place. Keep away from sources of ignition and heat.
Keep away from sources of ignition and heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Chemical-resistant, impervious gloves with an approved standards should be worn at all times. The selection of the glove material is based on the penetration times, rates of diffusion and its degradation. Material of gloves: PVC gloves, Neoprene gloves. The protection time of the gloves can not be accurately estimated for mixtures consisting of several substances. Refer to and observe manufacturers break through times of the protective gloves.
Safety glasses
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable under normal conditions.
No dangerous reactions known.
Heat.
Strong oxidizing agents.
Formation of toxic gases is possible during heating or in case of fire.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?
The signal word is warning.
What is the physical form of Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?
Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle] is a liquid appearing as brown, liquid with brown color. It has odorless odor.
What is Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle] used for?
Reference material for laboratory use only
What are the hazard statements for Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?
This substance has 1 hazard statement:
- H290: May be corrosive to metals.
What is the melting point of Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?
The melting point is Not determined. and the boiling point is 100 °C (212 °F).