NextSDS Logo
Safety Data Sheet EN

Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]
Product Code
5190-8588

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reference material for laboratory use only

Manufacturers & Suppliers

A

Agilent Technologies, Inc.

manufacturer

5301 Stevens Creek Blvd. Santa Clara, CA 95051 USA

800-227-9770

Emergency Contacts

CHEMTREC®

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Met. Corr. Cat. 1 H290

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H290 May be corrosive to metals.

Precautionary Statements

P234 Keep only in original container.
P390 Absorb spillage to prevent material damage.
P406 Store in corrosive resistant container with a resistant inner liner.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous solution. Also contains substances at levels not considered to be hazardous.

Chemical Name CAS Number Concentration Hazardous
hydrochloric acid 7647-01-0 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Rinse mouth. Do not induce vomiting.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective clothing.

Environmental

Dilute with plenty of water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Store in cool, dry place in tightly closed receptacles.

Storage

Store in a cool location. Please refer to the manufacturers certificate for specific storage and transport temperature conditions. Store only in the original receptacle. Keep container in a well-ventilated place. Keep away from sources of ignition and heat.

Fire prevention

Keep away from sources of ignition and heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Chemical-resistant, impervious gloves with an approved standards should be worn at all times. The selection of the glove material is based on the penetration times, rates of diffusion and its degradation. Material of gloves: PVC gloves, Neoprene gloves. The protection time of the gloves can not be accurately estimated for mixtures consisting of several substances. Refer to and observe manufacturers break through times of the protective gloves.

Eyes

Safety glasses

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
< 1.5
State Under Standard Conditions
---
Colour Intensity
---
Dynamic Viscosity
Not determined.
Physical State
liquid
Solubility In Fat
---
Crystallisation Point
---
Kinematic Viscosity
Not determined.
Vapor Pressure
23 hPa (17 mm Hg)
Bulk Density
---
Odor
Odorless
Upper Explosive Limit
---
Appearance
Brown, Liquid
Auto Ignition Temperature
Product is not selfigniting.
Vapor Density
Not determined.
Physical State Data
liquid
Colour
Brown
Form
Liquid
Lower Explosive Limit
---
Decomposition Temperature
Not determined.
Relative Density
Not determined.
Odor Threshold
Not determined.
Voc Content
---
Flammability
Not determined.
Relative Evaporation Rate
---
Molecular Weight
---
Softening Point
---
Partition Coefficient
Not determined.
Cloud Point
---
Evaporation Rate
Not determined.
Metal Corrosion
---
Solubility In Water
Fully miscible.
Properties Status
---
Boiling Point
100 °C (212 °F)
Flash Point
Not applicable.
Solubility
---
Density
1 g/cm³ (8.345 lbs/gal)
Melting Point
Not determined.
Explosive Limits
---
Freezing Point
---
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

No dangerous reactions known.

Avoid

Heat.

Incompatible

Strong oxidizing agents.

Decomposition

Formation of toxic gases is possible during heating or in case of fire.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?

The signal word is warning.

What is the physical form of Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?

Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle] is a liquid appearing as brown, liquid with brown color. It has odorless odor.

What is Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle] used for?

Reference material for laboratory use only

What are the hazard statements for Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?

This substance has 1 hazard statement:

  • H290: May be corrosive to metals.

What is the melting point of Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]?

The melting point is Not determined. and the boiling point is 100 °C (212 °F).