NextSDS Logo
Safety Data Sheet EN

Previcur® Fungicide

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Previcur® Fungicide
Product Code
05933765

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fungicide

Manufacturers & Suppliers

Bayer Cropscience Pty Ltd logo

Bayer Cropscience Pty Ltd

manufacturer

Level 4, 109 Burwood Rd, Hawthorn 3122, Victoria, Australia

(03) 9248 6888

http://www.crop.bayer.com.au

Emergency Contacts

IXOM Operations Pty Ltd

1800 033 111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.

Precautionary Statements

P261 Avoid breathing mist/ spray.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water/ soap.
P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/container in accordance with local regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Propamocarb hydrochloride 722 g/l (600g/l propamocarb) Soluble concentrate (SL)

Chemical Name CAS Number Concentration Hazardous
Propamocarb hydrochloride 25606-41-1 66.2% No
Other ingredients (non-hazardous) --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Keep patient warm and at rest. If symptoms persist, call a physician.

Skin contact

Wash off with soap and water. If symptoms persist, call a physician.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye. Get medical attention if irritation develops and persists.

Ingestion

Do NOT induce vomiting. Rinse mouth. Call a physician or poison control center immediately.

Immediate Medical Attention

Call a physician or poison control center immediately.

Medical Treatment

Appropriate supportive and symptomatic treatment as indicated by the patient's condition is recommended.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

High volume water jet

Specific hazards

Dangerous gases are evolved in the event of a fire.

Firefighter Protection

Wear self-contained breathing apparatus and protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with spilled product or contaminated surfaces. Keep people away from and upwind of spill/leak. When dealing with a spillage do not eat, drink or smoke.

Environmental

Do not allow to get into surface water, drains and ground water.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Collect and transfer the product into a properly labelled and tightly closed container. Clean contaminated floors and objects thoroughly, observing environmental regulations.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, eyes and clothing. Keep working clothes separately. Remove soiled clothing immediately and clean thoroughly before using again. Wash hands before breaks and immediately after handling the product.

Storage

Store in original container. Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from direct sunlight. Protect from frost.

Hygiene

Avoid contact with skin, eyes and clothing. Keep working clothes separately. Remove soiled clothing immediately and clean thoroughly before using again. Wash hands before breaks and immediately after handling the product.

Fire prevention

Keep away from heat and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only in area provided with appropriate exhaust ventilation.

Hands

Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Wash gloves when contaminated. Dispose of when contaminated inside, when perforated or when contamination on the outside cannot be removed. Wash hands frequently and always before eating, drinking, smoking or using the toilet. Material Nitrile rubber. Rate of permeability > 480 min. Glove thickness > 0.4 mm. Protective index Class 6. Directive Protective gloves complying with EN 374.

Eyes

Wear goggles (conforming to EN166, Field of Use = 5 or equivalent).

Respiratory

Respiratory protection is not required under anticipated circumstances of exposure. Respiratory protection should only be used to control residual risk of short duration activities, when all reasonably practicable steps have been taken to reduce exposure at source e.g. containment and/or local extract ventilation. Always follow respirator manufacturer's instructions regarding wearing and maintenance.

Skin/Body

Wear standard coveralls and Category 3 Type 4 suit. If there is a risk of significant exposure, consider a higher protective type suit. Wear two layers of clothing wherever possible. Polyester/cotton or cotton overalls should be worn under chemical protection suit and should be professionally laundered frequently.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
---
Melting Point
No data available
Explosive Limits
---
Freezing Point
---
State Under Standard Conditions
---
Solubility
---
Colour
colourless to light yellow
Ph
2.0 - 4.0 (100 %) (23 °C)
Odor
slightly perceptible
Partition Coefficient
Propamocarb hydrochloride: log Pow: -1.2
Physical State
liquid
Relative Evaporation Rate
---
Flammability
---
Vapor Pressure
---
Crystallisation Point
---
Solidification Point
---
Appearance
colourless to light yellow
Upper Explosive Limit
No data available
Molecular Weight
---
Kinematic Viscosity
No data available
Voc Content
---
Cloud Point
---
Physical State Data
liquid
Decomposition Temperature
---
Relative Density
---
Lower Explosive Limit
No data available
Bulk Density
---
Form
Liquid
Properties Status
---
Solubility In Fat
---
Colour Intensity
---
Metal Corrosion
---
Auto Ignition Temperature
The product is not self-ignitable.
Flash Point
> 100 °C No flash point - Determination conducted up to the boiling point.
Softening Point
---
Odor Threshold
No data available
Density
ca. 1.09 g/cm³ (20 °C)
Solubility In Water
completely miscible
Dynamic Viscosity
34.23 mPa.s (20 °C)
Evaporation Rate
---
Boiling Point
ca. 100 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

No hazardous reactions when stored and handled according to prescribed instructions.

Avoid

Extremes of temperature and direct sunlight.

Incompatible

Store only in the original container.

Decomposition

No decomposition products expected under normal conditions of use. Thermal decomposition can lead to release of: Carbon oxides, Nitrogen oxides (NOx)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Previcur® Fungicide?

The signal word is warning.

What is the physical form of Previcur® Fungicide?

Previcur® Fungicide is a liquid appearing as colourless to light yellow with colourless to light yellow color. It has slightly perceptible odor.

What is Previcur® Fungicide used for?

Fungicide

What are the hazard statements for Previcur® Fungicide?

This substance has 1 hazard statement:

  • H317: May cause an allergic skin reaction.

What is the melting point of Previcur® Fungicide?

The melting point is No data available and the boiling point is ca. 100 °C.