Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Magnesium perchlorate
- Product Code
- 11636
- Chemical Name
- Magnesium perchlorate
- Synonyms
- Perchloric acid magnesium salt
Regulatory Identifiers
- CAS Number
- 10034-81-8 Check regulations →
- EC Number
- 233-108-3 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
manufacturer
Shore Road, Heysham, Lancashire, LA3 2XY, United Kingdom
+44 (0) 1524 850506
Emergency Contacts
Information US
001-800-227-6701
Information Europe
+32 14 57 52 11
Emergency Number US
001-201-796-7100
Emergency Number Europe
+32 14 57 52 99
CHEMTREC US
001-800-424-9300
CHEMTREC Europe
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Magnesium perchlorate EC: 233-108-3 | 10034-81-8 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If breathing is difficult, give oxygen. Get medical attention.
Symptoms: Irritating to respiratory system.
Get medical attention. Wash off immediately with plenty of water for at least 15 minutes.
Symptoms: Irritating to skin.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Symptoms: Irritating to eyes.
Do NOT induce vomiting. Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Flooding quantities of water. Water mist may be used to cool closed containers.
Water.
Oxidizer: Contact with combustible/organic material may cause fire. Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Should not be released into the environment.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Potassium perchlorate
CAS: 7778-74-7
Magnesium chloride
CAS: 7786-30-3
Magnesium chloride
CAS: 7786-30-3
Ammonium perchlorate
CAS: 7790-98-9
Lead (II) perchlorate
CAS: 13453-62-8
Magnesium chloride, ACS
---
Magnesium chloride hexahydrate
CAS: 7791-18-6
Magnesium chloride hexahydrate
CAS: 7791-18-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation. Keep away from clothing and other combustible materials.
Keep containers tightly closed in a dry, cool and well-ventilated place. Store under an inert atmosphere.
Handle in accordance with good industrial hygiene and safety practice.
Do not store near combustible materials.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Contact with combustible/organic material may cause fire.
Moisture
Combustible/organic material
Phosgene. Hydrogen chloride gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1475
- Shipping Name
- MAGNESIUM PERCHLORATE
- Transport Class
- 5.1
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Magnesium perchlorate known by?
Magnesium perchlorate is also known as: Perchloric acid magnesium salt
What is the hazard signal word for Magnesium perchlorate?
The signal word is danger.
What is the physical form of Magnesium perchlorate?
Magnesium perchlorate is a solid appearing as white . It has odorless odor.
What is Magnesium perchlorate used for?
Laboratory chemicals.
What are the hazard statements for Magnesium perchlorate?
This substance has 4 hazard statements:
- H272: May intensify fire; oxidizer
- H315: Causes skin irritation
- H319: Causes serious eye irritation
- H335: May cause respiratory irritation
What is the melting point of Magnesium perchlorate?
The melting point is 250 °C / 482 °F and the boiling point is No information available.