Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dentsply IRM Liquid
- Synonyms
- Not Available
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For dental use only. Intermediate restorative material Zinc eugenol cement.
Manufacturers & Suppliers
Dentsply (Australia) Pty Ltd
national supplier
11-21 Gilby Road Mount Waverley VIC 3149 Australia
1300 55 29 29
www.dentsply.com.au
Emergency Contacts
Poisons Information Centre (AUSTRALIA)
13 11 26
24 hour service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| eugenol | 97-53-0 | 50% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If fumes, aerosols or combustion products are inhaled remove from contaminated area. Other measures are usually unnecessary.
Immediately remove all contaminated clothing, including footwear. Flush skin and hair with running water (and soap if available).
Wash out immediately with fresh running water. Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
If swallowed do NOT induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain open airway and prevent aspiration. Observe the patient carefully. Never give liquid to a person showing signs of being sleepy or with reduced awareness; i.e. becoming unconscious. Give water to rinse out mouth, then provide liquid slowly and as much as casualty can comfortably drink.
Immediate Medical Attention
Seek medical attention without delay; if pain persists or recurs seek medical attention (Eye). Seek medical attention in event of irritation (Skin). Seek medical advice (Ingestion).
Medical Treatment
Treat symptomatically. Establish a patent airway with suction where necessary. Watch for signs of respiratory insufficiency and assist ventilation as necessary. Administer oxygen by non-rebreather mask at 10 to 15 L/min. Monitor and treat, where necessary, for pulmonary oedema. Monitor and treat, where necessary, for shock. Anticipate seizures. Consider orotracheal or nasotracheal intubation for airway control in unconscious patient or where respiratory arrest has occurred. Positive-pressure ventilation using a bag-valve mask might be of use. Monitor and treat, where necessary, for arrhythmias. Start an IV D5W TKD. If signs of hypovolaemia are present use lactated Ringers solution. Fluid overload might create complications. Drug therapy should be considered for pulmonary oedema. Hypotension with signs of hypovolaemia requires the cautious administration of fluids. Treat seizures with diazepam.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, Dry chemical powder, BCF (where regulations permit), Carbon dioxide.
Combustible. Slight fire hazard when exposed to heat or flame. Heating may cause expansion or decomposition leading to violent rupture of containers. Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result.
Alert Fire Brigade and tell them location and nature of hazard. Prevent, by any means available, spillage from entering drains or water course. Use water delivered as a fine spray to control fire and cool adjacent area.
Firefighter Protection
Wear full body protective clothing with breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard.
Remove all ignition sources. Clean up all spills immediately. Avoid breathing vapours and contact with skin and eyes. Control personal contact with the substance, by using protective equipment.
Moderate hazard. Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. Wear breathing apparatus plus protective gloves.
Clean up all spills immediately.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
DO NOT allow clothing wet with material to stay in contact with skin. Avoid all personal contact, including inhalation. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Prevent concentration in hollows and sumps.
Store in original containers. Keep containers securely sealed. No smoking, naked lights or ignition sources. Store in a cool, dry, well-ventilated area.
No smoking, naked lights or ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection. The basic types of engineering controls are: Process controls which involve changing the way a job activity or process is done to reduce the risk. Enclosure and/or isolation of emission source which keeps a selected hazard "physically" away from the worker and ventilation that strategically "adds" and "removes" air in the work environment.
Wear chemical protective gloves, e.g. PVC. Wear safety footwear or safety gumboots, e.g. Rubber
Safety glasses with side shields. Chemical goggles. Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants. A written policy document, describing the wearing of lenses or restrictions on use, should be created for each workplace or task.
Type A-P Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). Where the concentration of gas/particulates in the breathing zone, approaches or exceeds the "Exposure Standard" (or ES), respiratory protection is required. Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content.
Overalls. P.V.C. apron. Barrier cream.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
• Unstable in the presence of incompatible materials. • Product is considered stable. • Hazardous polymerisation will not occur.
See section 7
See section 7
See section 7
See section 7
See section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Dentsply IRM Liquid known by?
Dentsply IRM Liquid is also known as: Not Available
What is the hazard signal word for Dentsply IRM Liquid?
The signal word is warning.
What is the physical form of Dentsply IRM Liquid?
Dentsply IRM Liquid is a liquid appearing as yellowish colour liquid with characteristic odour; does not mix with water. with yellowish color. It has characteristic odor.
What is Dentsply IRM Liquid used for?
For dental use only. Intermediate restorative material Zinc eugenol cement.
What are the hazard statements for Dentsply IRM Liquid?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
What is the melting point of Dentsply IRM Liquid?
The melting point is -10 °C and the boiling point is 254 °C.