Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BioMed Clear Resin
- Product Code
- FLBMCL01
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For use in Formlabs SLA Printers
Uses advised against
Not determined or not applicable.
Manufacturers & Suppliers
Formlabs Ohio, Inc
manufacturer
27800 Lemoyne Rd. Suite O Millbury, Ohio 43447
+1 419-837-9783
Emergency Contacts
CHEMTREC
1-800-424-9300
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Esterification products of 4,4'-isopropylidenediphenol, ethoxylated and 2methylprop-2-enoic acid | --- | 50 - 70% | No |
| Urethane dimethacrylate | --- | 25 - 45% | No |
| Methacrylate Monomer(s) | --- | 7 - 10% | No |
| Photoinitiator(s) | --- | 2% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove person to fresh air and place in a position comfortable for breathing. Keep person at rest. If breathing is difficult, administer oxygen. If breathing has stopped, provide artificial respiration. If experiencing respiratory symptoms, seek medical advice/attention.
Symptoms: Inhalation may have adverse effects on the respiratory tract. Symptoms may include cough, breathing difficulties, sore throat and inflammation of the mucous membrane lining the respiratory tract.
Remove contaminated clothing and shoes. Rinse skin with copious amounts of water [shower] for several minutes. Launder contaminated clothing before reuse. If symptoms develop or persist, seek medical advice/attention.
Symptoms: Skin contact may result in redness, pain, burning and inflammation. Dermal exposure may cause an allergic skin reaction. Symptoms may include irritation, redness, pain, rash, inflammation, itching, burning and dermatitis.
Rinse eyes with plenty of water for several minutes. Remove contact lenses if present and easy to do so. Protect unexposed eye. If symptoms develop or persist, seek medical advice/attention.
Symptoms: Eye contact may result in irritation, redness, pain, inflammation, itching, burning and tearing.
If swallowed, DO NOT induce vomiting unless told to do so by a physician or poison control center. Rinse mouth with water. Never give anything by mouth to an unconscious person. If spontaneous vomiting occurs, place on the left side with head down to prevent aspiration of liquid into the lungs. If symptoms develop or persist, seek medical advice/attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Emergency eye wash stations and safety showers should be available in the immediate vicinity of use or handling. Provide adequate ventilation to maintain the airborne concentrations of vapor, mists, and/or dusts below the applicable workplace exposure limits, while observing recognized national standards (or equivalent).
Chemical resistant, impervious gloves approved by the appropriate standards. Gloves must be inspected prior to use. Avoid skin contact with used gloves. Appropriate techniques should be used to remove used gloves and contaminated clothing.
Safety glasses or goggles. Use eye protection equipment that has been tested and approved by recognized national standards (or equivalent).
If engineering controls do not maintain airborne concentrations below the applicable workplace exposure limits, or to an acceptable level (if exposure limits have not been established), a respirator approved by recognized national standards (or equivalent) must be worn.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Ensure that all personal protective equipment is approved by recognized national standards (or equivalent).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 3082
- Shipping Name
- Environmentally hazardous liquid, N.O.S. Methacrylate Polymer
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BioMed Clear Resin?
The signal word is warning.
What is the physical form of BioMed Clear Resin?
BioMed Clear Resin is a liquid appearing as light purple transparent liquid with light purple color. It has characteristic acrylate odor.
What is BioMed Clear Resin used for?
For use in Formlabs SLA Printers
What are the hazard statements for BioMed Clear Resin?
This substance has 4 hazard statements:
- H315: Causes skin irritation
- H317: May cause an allergic skin reaction
- H319: Causes serious eye irritation
- H335: May cause respiratory irritation