NextSDS Logo
Safety Data Sheet EN

GM501 Collagenase

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GM501 Collagenase
Product Form
Mixture
Product Code
4 GM 501COLL

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For professional use only. Medium for the digestion of human testicular tissue obtained by testicular biopsy (TESE)

Uses advised against

No additional information available.

Manufacturers & Suppliers

G

Gynemed GmbH & Co. KG

manufacturer

Lübecker Straße 9, D-23738 Lensahn, Germany

Emergency Contacts

Emergency Contact

+49 (0)4363 90 32 90

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
EDTA-2Na EC: 205-358-3 6381-92-6 1% Yes
Alanyl-Glutamine EC: 475-290-9 39537-23-0 1% No
Solution (NON-ESS AA) --- 1% No
Solution (NON-ESS + ESS AA) --- 1% No
Ultrapure water EC: 231-791-2 7732-18-5 90% No
Sodium Chloride EC: 231-598-3 7647-14-5 1% No
Potassium Chloride EC: 231-211-8 7447-40-7 1% No
Calcium chloride dihydrate 10035-04-8 1% Yes
Potassium Dihydrogen Phosphate EC: 231-913-4 7778-77-0 1% No
Glucose anhydrous EC: 200-075-1 50-99-7 1% No
Sodium Hydrogen Carbonate EC: 205-633-7 144-55-8 1% No
HEPES EC: 230-907-9 7365-45-9 2% No
Magnesium Sulphate Heptahydrate 10034-99-8 1% No
Sodium Pyruvate EC: 204-024-4 113-24-6 1% No
Sodium lactate EC: 212-762-3 867-56-1 1% No
Clostridiopeptidase A EC: 232-582-9 9001-12-1 1000% Yes
Phenol Red Sodium Salt EC: 252-057-8 34487-61-1 1% Yes

Notes

The media do not contain any raw materials of direct animal-origin or materials that have been produced using animal-origin components. Components have not been in contact with material of animal origin during processing and therefore pose no TSE risk.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Assure fresh air breathing. Allow the victim to rest.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

Eye contact

Rinse immediately with plenty of water for at least 15 minutes. Obtain medical attention if pain, blinking or redness persist.

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

Do not use a heavy water stream.

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Ventilate area.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Rinse spill area with water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash Hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour.

Storage

Keep only in the original container away from direct (sun)light. Do not freeze. Do not use after expiry date. The product can be safely used up to 7 days after opening the container when sterile conditions are maintained and the products are stored at 2-8°C. Content cannot be resterilized after opening.

Hygiene

Wash Hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in accordance with good industrial hygiene and safety. Avoid all unnecessary exposure.

Hands

Wear protective gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to meet the specifications of EU-directive 89/686/EEC and the standard EN374 derived from it.

Eyes

Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).

Respiratory

Wear appropriate mask. Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Complete suit protecting against chemicals, flame retardant antistatic protective clothing. The type of protection must be selected according to the concentration and volume of the dangerous substance at the specific workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Colour
Red transparent coloured liquid
Dynamic Viscosity
No data available
Flammability
Non flammable
Auto Ignition Temperature
No data available
Ph
7.10 – 7.40
State Under Standard Conditions
---
Density
---
Boiling Point
No data available
Physical State Data
liquid
Form
---
Vapor Pressure
No data available
Odor Threshold
No data available
Solidification Point
---
Flash Point
No data available
Relative Density
No data available
Physical State
Liquid
Cloud Point
---
Relative Evaporation Rate
No data available
Appearance
Red transparent coloured liquid
Crystallisation Point
---
Melting Point
No data available
Colour Intensity
---
Evaporation Rate
---
Odor
Odourless
Vapor Density
---
Kinematic Viscosity
No data available
Softening Point
---
Solubility In Fat
---
Bulk Density
---
Decomposition Temperature
No data available
Properties Status
---
Voc Content
---
Freezing Point
No data available
Explosive Limits
---
Solubility In Water
complete
Metal Corrosion
---
Lower Explosive Limit
No data available
Solubility
Highly soluble in water. Water: complete
Partition Coefficient
No data available
Upper Explosive Limit
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

No additional information available.

Hazardous reactions

Not established.

Avoid

Direct (sun)light. Extremely high or low temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GM501 Collagenase?

The signal word is no signal word.

What is the physical form of GM501 Collagenase?

GM501 Collagenase is a liquid appearing as red transparent coloured liquid with red transparent coloured liquid color. It has odourless odor.

What is the solubility of GM501 Collagenase?

Highly soluble in water. Water: complete

What is GM501 Collagenase used for?

For professional use only. Medium for the digestion of human testicular tissue obtained by testicular biopsy (TESE)

What is the melting point of GM501 Collagenase?

The melting point is No data available and the boiling point is No data available.