Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- GM501 SpermMobil
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
GM501 SpermMobil is a reagent designed for in vitro procedures, examination and assessment of human necrozoospermic ejaculates as well as immotile sperms.
Manufacturers & Suppliers
Gynemed GmbH & Co. KG
manufacturer
Lübecker Straße 9, 23738 Lensahn, Germany
Emergency Contacts
Emergency Contact
+49 (0) 4363 903290
only available during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS07
Hazard Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Water | 7732-18-5 | 90% | No |
| NaCl | 7647-14-5 | 1% | No |
| KCl | 7447-40-7 | 1% | No |
| CaCl₂.2H₂O | 10035-04-8 | 1% | No |
| MgSO₄.7H₂O | 10034-99-8 | 1% | No |
| Na-Pyruvate | 113-24-6 | 1% | No |
| KH₂PO₄ | 7778-77-0 | 1% | No |
| D(+) Glucose anhydrous | 50-99-7 | 1% | No |
| Na-Lactate | 867-56-1 | 1% | No |
| NaHCO₃ | 144-55-8 | 1% | No |
| EDTA-2Na | 6381-92-6 | 1% | No |
| Solution (NON-ESS AA) | --- | 1% | No |
| Solution (NESS+ESS AA) | --- | 1% | No |
| Alanyl-glutamine | 39537-23-0 | 1% | No |
| HSA | 70024-90-7 | 0.5% | No |
| Gentamicin sulfate | 1405-41-0 | 1% | No |
| HEPES | 7365-45-9 | 1% | No |
| Phenol Red sodium salt | 34487-61-1 | 1% | No |
| Theophylline | 58-55-9 | 1% | No |
GM501 SpermMobil does not contain any raw materials of direct animal-origin or materials that have been produced using animal-origin components. Components have not been in contact with material of animal origin during processing and therefore pose no TSE risk.
First Aid Measures
Emergency procedures for chemical exposure incidents
Not a likely source of exposure.
Wash after each contact.
Flush with copious amounts of water for at least 15 minutes. Insure adequate flushing by separating the eyelids with fingers.
Wash out mouth with water (see doctor when swallowed).
Immediate Medical Attention
Obtain medical attention if any discomfort should occur. See doctor when swallowed.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Not applicable
Not applicable
Not applicable
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not applicable
Rinse spill area with water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
See heading 8.
Store at 2-8°C. Do not freeze before use. Keep away from sunlight. After opening the container, do not use the product longer than 7 days. Do not use after expiry date.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear rubber gloves.
Wear chemical safety goggles.
Not applicable
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
None known
None known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for GM501 SpermMobil?
The signal word is warning.
What is the physical form of GM501 SpermMobil?
GM501 SpermMobil is a red transparent liquid appearing as red transparent liquid, odourless with red color. It has odourless odor.
What is the solubility of GM501 SpermMobil?
Highly soluble in water
What is GM501 SpermMobil used for?
GM501 SpermMobil is a reagent designed for in vitro procedures, examination and assessment of human necrozoospermic ejaculates as well as immotile sperms.
What are the hazard statements for GM501 SpermMobil?
This substance has 3 hazard statements:
- H302: May be harmful by ingestion.
- H316: May cause skin or eye irritation.
- H335: May be irritating to mucous membranes and upper respiratory tract.