NextSDS Logo
Safety Data Sheet EN

Oosafe® Laboratory Surface Disinfectant

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Oosafe® Laboratory Surface Disinfectant
Product Code
OODSF-0050; OODSF-02000; OODSF-10000

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Disinfectant for surfaces; Product type 2: Private area and public health area disinfectants and other public health area biocidal products especially suited for IVF laboratories; For disinfection and cleaning of laboratory surfaces. Especially is suitable for IVF laboratories. Only for professional use.

Manufacturers & Suppliers

S

Sparmed Aps

manufacturer

Ryttermarken 2, DK-3520, Farum, Denmark

Emergency Contacts

Danish Poison Line

+45 82 12 12 12

Emergency Contact

+45 39 40 25 03

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

P102 Keep out of the reach of children.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed above with non-hazardous additions.

Chemical Name CAS Number Concentration Hazardous
N,N-didecyl-N-methyl-poly(oxethyl)ammonium priopionate 94667-33-1 6.3% No

For the wording of the listed risk-phrases refer to section 15

Notes

Dangerous components: No dangerous components.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints

Skin contact

The product is not irritating for the skin

Eye contact

Rinse open eye for 10min under running water. Force to open eyelids. Consult a doctor if irritation persists.

Ingestion

Call a physician immediately. Clean mouth with water and drink afterwards plenty of water. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry powder, water spray, foam.

Specific hazards

Heating or fire can release toxic gas.

Instructions

Use water spray to cool unopened containers.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required

Environmental

Dilute with plenty of water.

Cleanup methods

Absorb with liquid- binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required if used properly

Storage

Keep away from heat and direct sunlight.

Fire prevention

No special measures required

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The selection of suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Goggles recommended during refilling.

Respiratory

Not required

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
---
Relative Evaporation Rate
---
Voc Content
---
Solubility In Water
completely miscible
Ph
6.0 - 7.0
Auto Ignition Temperature
---
Flammability
---
Upper Explosive Limit
15,0 Vol%
Bulk Density
---
Solubility In Fat
---
Odor Threshold
---
State Under Standard Conditions
---
Colour Intensity
---
Molecular Weight
---
Decomposition Temperature
---
Appearance
---
Physical State
Liquid
Colour
According to product specification
Vapor Pressure
59mbar (at 20°C)
Lower Explosive Limit
2,6 Vol%
Flash Point
>100°C
Properties Status
---
Physical State Data
liquid
Softening Point
---
Solidification Point
---
Kinematic Viscosity
---
Solubility
---
Dynamic Viscosity
---
Explosive Limits
---
Crystallisation Point
---
Odor
Slightly aromatic
Vapor Density
---
Metal Corrosion
---
Relative Density
---
Boiling Point
100°C
Form
Liquid
Freezing Point
---
Melting Point
undetermined
Evaporation Rate
---
Density
0,9600 g/cm³ (at 20°C)
Cloud Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications;

Hazardous reactions

No dangerous reactions known if used according to specifications;

Avoid

See. Section 7;

Decomposition

No dangerous decomposition products known if used according to specifications.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Oosafe® Laboratory Surface Disinfectant?

The signal word is no signal word.

What is the physical form of Oosafe® Laboratory Surface Disinfectant?

Oosafe® Laboratory Surface Disinfectant is a liquid with according to product specification color. It has slightly aromatic odor.

What is Oosafe® Laboratory Surface Disinfectant used for?

Disinfectant for surfaces; Product type 2: Private area and public health area disinfectants and other public health area biocidal products especially suited for IVF laboratories; For disinfection and cleaning of laboratory surfaces. Especially is suitable for IVF laboratories. Only for professional use.

What is the melting point of Oosafe® Laboratory Surface Disinfectant?

The melting point is undetermined and the boiling point is 100°C.