01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
i-protect Surface Disinfectant

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Disinfection and cleaning of surfaces

Uses advised against

All other use is prohibited unless specifically permitted

Manufacturers & Suppliers

i

i-team Hygiene

national supplier

Hoppenkuil 31, 5626 DD EINDHOVEN, The Netherlands

00 31 40 266 24 77

Emergency Contacts

Emergency Contact

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

P102 Keep out of reach of children

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
CHLORINE DIOXIDE EC: 233-162-8 10049-04-4 0.2% Yes
DODECYLDIMETHYLAMINE OXIDE EC: 216-700-6 1643-20-5 0.2% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Fresh air and rest. If symptoms persist seek medical advice.

Symptoms: Inhalation of heated product may cause airway irritation.

Skin contact

Normal washing of the skin is considered sufficient. Remove contaminated clothing.

Symptoms: prolonged exposure can cause skin irritation.

Ingestion

First rinse the mouth thoroughly with water and SPIT OUT the rinse water. Then drink at least half a litre of water. DO NOT induce VOMITING.

Symptoms: Ingestion may cause discomfort or reduced general condition.

Immediate Medical Attention

Contact a doctor if complaints persist.

Medical Treatment

Symptomatic treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Extinguish with materials intended for the surrounding fire.

Specific hazards

Corrosive gases can be spread during fire and substantial heating.

Instructions

Protective measures should be taken regarding other material at the site of the fire.

Firefighter Protection

In case of fire use proper breathing apparatus. Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid direct inhalation of fumes from the product. Avoid contact with eyes. Ensure good ventilation. Note that there is a risk of slipping if product is leaking/spilling.

Small spill

Smaller spills, clean up with cloth or similar and wash with water.

Large spill

For larger spills cover potential drains and wall in with absorbent inert material such as sand, dirt, vermiculite or diatomaceous earth.

Environmental

Avoid emissions into soil, water or air.

Cleanup methods

Collect in appropriate containers.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Work in order to avoid spillage. If spillage does occur, address it immediately in accordance with the directions specified in Section 6 of this safety data sheet. Avoid spilling and avoid contact with skin and eyes. The usual precautionary measures for handling chemicals must be observed.

Storage

Store in a ventilated space. Must not be frozen. Do not store in direct sunlight. Do not store above normal room temperature.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in premises which have modern ventilation standards.

Hands

Protective gloves are normally not needed due to the properties of this product, but may be necessary for other reasons, e.g. mechanical risks, temperature conditions or microbiological risks.

Eyes

Eye protection should be worn if there is any danger of direct exposure or splashing.

Respiratory

Respiratory protection is not normally required. In case of inadequate ventilation, full or half mask with filter B (gray for inorganic gases and vapors) should be used.

Environmental

For limiting environmental exposure, see section 12.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
100 °C
Cloud Point
---
Partition Coefficient
Not applicable
Flash Point
Not indicated
Colour Intensity
---
Solidification Point
---
Relative Density
1.000 kg/L
Decomposition Temperature
Not indicated
Metal Corrosion
---
Softening Point
---
Solubility In Fat
---
Vapor Pressure
0.01 kPa
Flammability
Not applicable
Form
liquid
Physical State Data
liquid
Auto Ignition Temperature
Not indicated
Dynamic Viscosity
---
Upper Explosive Limit
Not indicated
Molecular Weight
---
Solubility In Water
---
Odor Threshold
Not indicated
Ph
1.8 - 2.2
Relative Evaporation Rate
---
Explosive Limits
---
Colour
light yellow
Properties Status
---
Voc Content
---
Physical State
liquid
Solubility
Not indicated
State Under Standard Conditions
---
Freezing Point
---
Crystallisation Point
---
Vapor Density
---
Melting Point
Not indicated
Appearance
Form: liquid. Colour: light yellow.
Evaporation Rate
Not indicated
Lower Explosive Limit
Not indicated
Kinematic Viscosity
1 mm²/s
Density
---
Odor
weak smell
Bulk Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Chlorine dioxide slowly decomposes in aqueous solution to among other things hydrochloric acid and chloric acid.

Reactivity

The product contains no substances which can lead to hazardous reactions at normal use.

Hazardous reactions

No hazardous reactions known during normal use.

Avoid

Protect from heat and direct sunlight. Avoid exposure to non-noble metallic materials longer than what is necessary for exterior disinfection. Avoid frost.

Incompatible

Avoid contact with alkaline products. Avoid contact with sulfur compounds. Avoid contact with oxidizers and reducing agents.

Decomposition

Chlorite. Chlorate.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for i-protect Surface Disinfectant?

The signal word is no signal word.

What is the physical form of i-protect Surface Disinfectant?

i-protect Surface Disinfectant is a liquid appearing as form: liquid. colour: light yellow. with light yellow color. It has weak smell odor.

What is the solubility of i-protect Surface Disinfectant?

Not indicated

What is i-protect Surface Disinfectant used for?

Disinfection and cleaning of surfaces

What is the melting point of i-protect Surface Disinfectant?

The melting point is Not indicated and the boiling point is 100 °C.